Pinhole aperture design for I-131 tumor imaging

被引:32
|
作者
Smith, MF [1 ]
Jaszczak, RJ [1 ]
Wang, HL [1 ]
机构
[1] DUKE UNIV, MED CTR, DEPT RADIOL, DURHAM, NC 27710 USA
关键词
D O I
10.1109/23.596980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new pinhole aperture design for single photon imaging is introduced whose distinctive feature is a cylindrical channeled aperture. This allows greater attenuation near the pinhole aperture, which is especially important when imaging I-131 with its medium and high energy emissions. The new design reduces to a conventional knife-edge aperture when the channel height is zero. Point source response functions were simulated for pinhole inserts with different pinhole diameters (0.4 - 2.0 mm diameter) and channel heights (0.1 - 3.0 mm) with acquisition parameters appropriate for I-131 brain tumor imaging. A photon transport simulation code was used to comprehensively model photon transport and detection. Tradeoff curves between resolution and sensitivity suggest that varying pinhole diameter and channel height to achieve higher resolution at the expense of decreased sensitivity may be advantageous for imaging tumors with intratumoral administration of I-131 radiolabeled monoclonal antibodies.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [31] Impact of collimator characteristics on quantitative I-131 imaging
    Autret, D.
    Ferrer, L.
    Bitar, A.
    Lisbona, A.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S110 - S111
  • [32] APPLICATIONS OF [I-131] M-IODOBENZYLGUANIDINE ([I-131]MIBG)
    BEIERWALTES, WH
    NUCLEAR MEDICINE AND BIOLOGY, 1987, 14 (03): : 183 - 189
  • [33] Pinhole imaging of 131I-metaiodobenzylguanidine (131I-MIBG) in an animal model of neuroblastoma
    Roberto Accorsi
    Michael J. Morowitz
    Martin Charron
    John M. Maris
    Pediatric Radiology, 2003, 33 : 688 - 692
  • [34] IMAGING AND TREATMENT OF DISSEMINATED NEUROBLASTOMA WITH I-131 METAIODOBENZYLGUANIDINE
    GERRARD, M
    EDEN, OB
    MERRICK, MV
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (712): : 393 - 395
  • [35] DISPOSITION OF I-131 PROINSULIN IN RAT - COMPARISONS WITH I-131 INSULIN
    IZZO, JL
    RONCONE, AM
    HELTON, DL
    IZZO, MJ
    DIABETES, 1978, 27 (04) : 400 - 410
  • [36] DISCORDANT IMAGING OF A THYROID NODULE WITH I-131 AND TC-99M - CONCORDANCE OF I-131 AND FLUORESCENT SCANS
    THRALL, JH
    BURMAN, KD
    WARTOFSKY, L
    CORCORAN, RJ
    JOHNSON, MC
    GILLIN, MT
    RADIOLOGY, 1978, 128 (03) : 705 - 706
  • [37] False-positive I-131 whole-body imaging after I-131 therapy for a follicular carcinoma
    Andreas, J
    Bruhl, K
    Eissner, AD
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (02) : 123 - 124
  • [38] Comparison of 4 different gamma cameras in pinhole collimator imaging of a thyroid phantom with I-131 and Tc-99m
    DaCosta, Maria
    Muzinic, Michael
    Tan, Dennis
    Rasuli, Asad
    Knesaurek, Karin
    Machac, Josef
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [39] Trends in thyroid imaging system for I-131 whole body imaging
    Lam, Honnam
    Muroni, Peter
    Voslar, Ann
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [40] ON THE DECAY OF I-131
    THULIN, S
    PHYSICAL REVIEW, 1951, 83 (04): : 860 - 861