Pinhole aperture design for I-131 tumor imaging

被引:32
|
作者
Smith, MF [1 ]
Jaszczak, RJ [1 ]
Wang, HL [1 ]
机构
[1] DUKE UNIV, MED CTR, DEPT RADIOL, DURHAM, NC 27710 USA
关键词
D O I
10.1109/23.596980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new pinhole aperture design for single photon imaging is introduced whose distinctive feature is a cylindrical channeled aperture. This allows greater attenuation near the pinhole aperture, which is especially important when imaging I-131 with its medium and high energy emissions. The new design reduces to a conventional knife-edge aperture when the channel height is zero. Point source response functions were simulated for pinhole inserts with different pinhole diameters (0.4 - 2.0 mm diameter) and channel heights (0.1 - 3.0 mm) with acquisition parameters appropriate for I-131 brain tumor imaging. A photon transport simulation code was used to comprehensively model photon transport and detection. Tradeoff curves between resolution and sensitivity suggest that varying pinhole diameter and channel height to achieve higher resolution at the expense of decreased sensitivity may be advantageous for imaging tumors with intratumoral administration of I-131 radiolabeled monoclonal antibodies.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [1] Pinhole aperture design for I-131 tumor imaging
    Smith, MF
    Jaszczak, RJ
    Wang, HL
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1109 - 1113
  • [2] Imaging I-131 distributions in brain tumor phantoms with pinhole SPECT.
    Smith, MF
    Gilland, DR
    Jaszczak, RJ
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 965 - 965
  • [3] Evaluation of a pinhole collimator for I-131 SPECT head imaging
    Gilland, DR
    Johnson, EL
    Turkington, TG
    Coleman, RE
    Jaszczak, RJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2230 - 2238
  • [4] Use of an analytic model of pinhole aperture penetration for resolution recovery in I-131 pinhole SPECT.
    Smith, MF
    Jaszczak, RJ
    Coleman, RE
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 210 - 210
  • [5] Application of lead and tungsten pinhole inserts to I-131 SPECT tumor imaging: A Monte Carlo investigation
    Smith, MF
    Jaszczak, RJ
    Wang, HL
    Li, JY
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1529 - 1533
  • [6] Lead and tungsten pinhole inserts for I-131 SPECT tumor imaging: Experimental measurements and photon transport simulations
    Smith, MF
    Jaszczak, RJ
    Wang, HL
    Li, JY
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) : 74 - 82
  • [7] I-131 DNASE, A POTENTIAL TUMOR IMAGING AGENT
    RESKE, SN
    VYSKA, K
    RESKE, K
    FEINENDEGEN, LE
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (06) : P36 - P36
  • [8] Phantom substernal goiter: An artifact of pinhole collimation with I-131
    Kikut, JK
    Fine, EJ
    RADIOLOGY, 1998, 209P : 403 - 404
  • [9] Seven-Pinhole Vs Single-Pinhole SPECT Imaging for Preablation I-131 Scans in the Treatment of Thyroid Cancer
    Yu, T.
    Bowsher, J.
    Reiman, R.
    MEDICAL PHYSICS, 2018, 45 (06) : E511 - E511
  • [10] I-131 Uptake in an Ovarian Tumor Differential Diagnosis for Abdominal I-131 Uptake
    Kraft, Otakar
    Mrhac, Lubomir
    Sirucek, Pavel
    Dvorackova, Jana
    Chmelova, Jana
    Graf, Petar
    Sevcik, Libor
    CLINICAL NUCLEAR MEDICINE, 2009, 34 (06) : 390 - 392