Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance

被引:33
|
作者
Chiribiri, Amedeo [1 ,2 ,3 ]
Schuster, Andreas [1 ,2 ,3 ]
Ishida, Masaki [1 ,2 ,3 ]
Hautvast, Gilion [4 ]
Zarinabad, Niloufar [1 ,2 ,3 ]
Morton, Geraint [1 ,2 ,3 ]
Otton, James [1 ,2 ,3 ]
Plein, Sven [1 ,2 ,3 ,5 ]
Breeuwer, Marcel [4 ,6 ]
Batchelor, Philip [1 ,2 ,3 ]
Schaeffter, Tobias [1 ,2 ,3 ]
Nagel, Eike [1 ,2 ,3 ]
机构
[1] Kings Coll London, NIHR Biomed Res Ctr, Div Imaging Sci, BHF Ctr Excellence, London SE1 7EH, England
[2] Wellcome Trust Res Labs, London, England
[3] Guys & St Thomas NHS Fdn Trust, Rayne Inst, EPSRC Med Engn Ctr, London, England
[4] Philips Healthcare, Imaging Syst MR, Best, Netherlands
[5] Univ Leeds, Div Cardiovasc & Neuronal Remodelling, Leeds, W Yorkshire, England
[6] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
first-pass perfusion MR; phantom; gadolinium; 3T; heart; CORONARY-ARTERY-DISEASE; MODEL-INDEPENDENT DECONVOLUTION; POSITRON-EMISSION-TOMOGRAPHY; BLOOD-FLOW; CONTRAST AGENTS; HEALTHY HUMANS; K-SPACE; RESERVE; MRI; QUANTIFICATION;
D O I
10.1002/mrm.24299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to controlled variations of myocardial perfusion rate, contrast agent dose, and cardiac output. It produced distinct signal intensity curves for perfusion rates ranging from 1 to 10 mL/mL/min. Quantification of myocardial blood flow by signal deconvolution techniques provided accurate measurements of perfusion. The phantom also proved to be very reproducible between different sessions and different operators. This novel hardware perfusion phantom system allows reliable, reproducible, and efficient simulation of myocardial first-pass MR perfusion. Direct comparison between the results of image-based quantification and reference values of flow and myocardial perfusion will allow development and validation of accurate quantification methods. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:698 / 707
页数:10
相关论文
共 50 条
  • [31] Abnormally heterogeneous myocardial perfusion in syndrome X detected by first-pass magnetic resonance imaging.
    Panting, JR
    Gatehouse, PD
    Burger, P
    Grothues, F
    Firmin, DN
    Collins, PD
    Pennell, DJ
    CIRCULATION, 2000, 102 (18) : 686 - 686
  • [32] Ruptured Aneurysm of the Sinus of Valsalva Insights From Magnetic Resonance First-Pass Myocardial Perfusion Imaging
    Schuster, Andreas
    Hedstroem, Erik
    Blauth, Christopher
    Marber, Michael S.
    Nagel, Eike
    Carr-White, Gerald
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (05) : 538 - 538
  • [33] Steady-state first-pass perfusion (SSFPP): A 3D TWIST in myocardial first-pass perfusion imaging
    Shivraman Giri
    Hui Xue
    Abdul Wattar
    Yu Ding
    Randall M Kroeker
    Gerhard Laub
    Peter Kellman
    Sven Zuehlsdorff
    Subha V Raman
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [34] Quantitative magnetic resonance first-pass perfusion analysis:: Interand intraobserver agreement
    Mühling, OM
    Dickson, ME
    Zenovich, A
    Huang, YM
    Wilson, BV
    Wilson, RF
    Anand, IS
    Seethamraju, RT
    Jerosch-Herold, M
    Wilke, NM
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (03) : 247 - 256
  • [35] Dynamic simulation of first pass myocardial perfusion MR with a novel perfusion phantom
    Chiribiri A.
    Schuster A.
    Ishida M.
    Hautvast G.
    Nooralipour N.Z.
    Paul M.
    Hussain S.
    Batchelor P.
    Breeuwer M.
    Schaeffter T.
    Nagel E.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [36] Characterization of microvascular dysfunction after acute myocardial infarction by cardiovascular magnetic resonance first-pass perfusion and late gadolinium enhancement imaging
    Yan, Andrew T.
    Gibson, C. Michael
    Larose, Eric
    Anavekar, Nagesh S.
    Tsang, Sui
    Solomon, Scott D.
    Reynolds, Glenn
    Kwong, Raymond Y.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (06) : 831 - 837
  • [37] Re: Assessment of coronary microvascular dysfunction in hypertrophic cardiomyopathy: First-pass myocardial perfusion cardiovascular magnetic resonance imaging at 1.5 T
    Daniowicz-Szymanowicz, L.
    Dorniak, K.
    Szurowska, E.
    Dudziak, M.
    Raczak, G.
    CLINICAL RADIOLOGY, 2014, 69 (03) : E163 - E164
  • [38] Steady-State First-Pass Perfusion (SSFPP): A New Approach to 3D First-Pass Myocardial Perfusion Imaging
    Giri, Shivraman
    Xue, Hui
    Maiseyeu, Andrei
    Kroeker, Randall
    Rajagopalan, Sanjay
    White, Richard D.
    Zuehlsdorff, Sven
    Raman, Subha V.
    Simonetti, Orlando P.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 133 - 144
  • [39] 1 M Gd-chelate (gadobutrol) for multislice first-pass magnetic resonance myocardial perfusion imaging
    Fenchel, M.
    Franow, A.
    Martirosian, P.
    Engels, M.
    Kramer, U.
    Stauder, N. I.
    Helber, U.
    Vogler, H.
    Claussen, C. D.
    Miller, S.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (959): : 884 - 892
  • [40] The additive effects of obesity on myocardial microcirculation in diabetic individuals: a cardiac magnetic resonance first-pass perfusion study
    Jiang, Li
    Shi, Ke
    Guo, Ying-kun
    Ren, Yan
    Li, Zhen-lin
    Xia, Chun-chao
    Li, Lei
    Liu, Xi
    Xie, Lin-jun
    Gao, Yue
    Shen, Meng-ting
    Deng, Ming-yan
    Yang, Zhi-gang
    CARDIOVASCULAR DIABETOLOGY, 2020, 19 (01)