A statistical approach to correct X-ray response non-uniformity in microstrip detectors for high-accuracy and high-resolution total-scattering measurements

被引:40
|
作者
Kato, Kenichi [1 ,2 ]
Tanaka, Yoshihito [3 ]
Yamauchi, Miho [4 ,5 ]
Ohara, Koji [6 ]
Hatsui, Takaki [1 ]
机构
[1] RIKEN SPring 8 Ctr, 1-1-1 Kouto, Sayo, Hyogo 6795148, Japan
[2] JST, PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 3320012, Japan
[3] Univ Hyogo, Grad Sch Mat Sci, 3-2-1 Kouto, Kamigori, Hyogo 6781297, Japan
[4] Kyushu Univ, Int Inst Carbon Neutral Energy Res WPI I2CNER, Nishi Ku, 744 Moto Oka, Fukuoka, Fukuoka 8190395, Japan
[5] Kyushu Univ, Dept Chem, Fac Sci, Nishi Ku, 744 Moto Oka, Fukuoka, Fukuoka 8190395, Japan
[6] SPring 8, Japan Synchrotron Radiat Res Inst JASRI, Res & Utilizat Div, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
关键词
total scattering; pair distribution functions; microstrip detectors; flat-field calibration; Poisson noise; PAIR DISTRIBUTION FUNCTION; POWDER DIFFRACTION; MYTHEN DETECTOR;
D O I
10.1107/S1600577519002145
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An unbiased approach to correct X-ray response non-uniformity in microstrip detectors has been developed based on the statistical estimation that the scattering intensity at a fixed angle from an object is expected to be constant within the Poisson noise. Raw scattering data of SiO2 glass measured by a microstrip detector module was found to show an accuracy of 12 sigma(PN) at an intensity of 10(6) photons, where sigma(PN) is the standard deviation according to the Poisson noise. The conventional flat-field calibration has failed in correcting the data, whereas the alternative approach used in this article successfully improved the accuracy from 12 sigma(PN) to 2 sigma(PN). This approach was applied to total-scattering data measured by a gapless 15-modular detector system. The quality of the data is evaluated in terms of the Bragg reflections of Si powder, the diffuse scattering of SiO2 glass, and the atomic pair distribution function of TiO2 nanoparticles and Ni powder.
引用
收藏
页码:762 / 773
页数:12
相关论文
共 50 条
  • [31] High-resolution X-ray Raman scattering and the study of ices under high pressure
    Cai, Yong
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C158 - C158
  • [32] The non-equilibrium response of a high-resolution Ti/Au X-ray microcalorimeter
    Terracol, S
    Miyazaki, T
    Morita, U
    Ishisaki, Y
    Tanaka, K
    Mitsuda, K
    Friedrich, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 300 - 302
  • [33] On the use of CCD area detectors for high-resolution specular X-ray reflectivity
    Fenter, P.
    Catalano, J. G.
    Park, C.
    Zhang, Z.
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 293 - 303
  • [34] Silicon Drift Detectors and CUBE Preamplifiers for High-Resolution X-ray Spectroscopy
    Quaglia, R.
    Bombelli, L.
    Busca, P.
    Fiorini, C.
    Occhipinti, M.
    Giacomini, G.
    Ficorella, F.
    Picciotto, A.
    Piemonte, C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 221 - 227
  • [35] Application of Low-Temperature Detectors to High-Resolution X-ray Spectroscopy
    Kilbourne, Caroline A.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 419 - 425
  • [36] HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT DETECTORS AND INTEGRATED ELECTRONICS
    BERTUCCIO, G
    SAMPIETRO, M
    FAZZI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 538 - 542
  • [37] Metallic magnetic calorimeters (MMC): detectors for high-resolution X-ray spectroscopy
    Fleischmann, A
    Link, M
    Daniyarov, T
    Rotzinger, H
    Enss, C
    Seidel, GM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 27 - 31
  • [38] Development of superconducting tunnel junction detectors for high-resolution X-ray spectroscopy
    Angloher, G
    Beckhoff, B
    Bühler, M
    von Feilitzsch, F
    Hertrich, T
    Hettl, P
    Höhne, J
    Huber, M
    Jochum, J
    Mössbauer, RL
    Schnagl, J
    Scholze, F
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2): : 214 - 219
  • [39] Modular multichannel acquisition system for high-resolution X-ray spectroscopy detectors
    Guazzoni, C
    Buzzetti, S
    Longoni, A
    Arnaboldi, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1199 - 1203
  • [40] HIGH-RESOLUTION K X-RAY ANGULAR-DISTRIBUTION MEASUREMENTS
    WANG, DW
    WATSON, RL
    KENEFICK, RA
    CHURCH, DA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 202 (1-2): : 355 - 360