A statistical approach to correct X-ray response non-uniformity in microstrip detectors for high-accuracy and high-resolution total-scattering measurements

被引:40
|
作者
Kato, Kenichi [1 ,2 ]
Tanaka, Yoshihito [3 ]
Yamauchi, Miho [4 ,5 ]
Ohara, Koji [6 ]
Hatsui, Takaki [1 ]
机构
[1] RIKEN SPring 8 Ctr, 1-1-1 Kouto, Sayo, Hyogo 6795148, Japan
[2] JST, PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 3320012, Japan
[3] Univ Hyogo, Grad Sch Mat Sci, 3-2-1 Kouto, Kamigori, Hyogo 6781297, Japan
[4] Kyushu Univ, Int Inst Carbon Neutral Energy Res WPI I2CNER, Nishi Ku, 744 Moto Oka, Fukuoka, Fukuoka 8190395, Japan
[5] Kyushu Univ, Dept Chem, Fac Sci, Nishi Ku, 744 Moto Oka, Fukuoka, Fukuoka 8190395, Japan
[6] SPring 8, Japan Synchrotron Radiat Res Inst JASRI, Res & Utilizat Div, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
关键词
total scattering; pair distribution functions; microstrip detectors; flat-field calibration; Poisson noise; PAIR DISTRIBUTION FUNCTION; POWDER DIFFRACTION; MYTHEN DETECTOR;
D O I
10.1107/S1600577519002145
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An unbiased approach to correct X-ray response non-uniformity in microstrip detectors has been developed based on the statistical estimation that the scattering intensity at a fixed angle from an object is expected to be constant within the Poisson noise. Raw scattering data of SiO2 glass measured by a microstrip detector module was found to show an accuracy of 12 sigma(PN) at an intensity of 10(6) photons, where sigma(PN) is the standard deviation according to the Poisson noise. The conventional flat-field calibration has failed in correcting the data, whereas the alternative approach used in this article successfully improved the accuracy from 12 sigma(PN) to 2 sigma(PN). This approach was applied to total-scattering data measured by a gapless 15-modular detector system. The quality of the data is evaluated in terms of the Bragg reflections of Si powder, the diffuse scattering of SiO2 glass, and the atomic pair distribution function of TiO2 nanoparticles and Ni powder.
引用
收藏
页码:762 / 773
页数:12
相关论文
共 50 条
  • [1] On-demand correction for X-ray response non-uniformity in microstrip detectors by a data-driven approach
    Kato, Kenichi
    Shigeta, Kazuya
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1172 - 1179
  • [2] High-Precision X-ray Total Scattering Measurements Using a High-Accuracy Detector System
    Kato, Kenichi
    Shigeta, Kazuya
    CONDENSED MATTER, 2022, 7 (01):
  • [3] High-resolution x-ray scattering measurements: I. Surfaces
    Daillant, J
    Alba, M
    REPORTS ON PROGRESS IN PHYSICS, 2000, 63 (10) : 1725 - 1777
  • [4] High-resolution X-ray mapping of CdZnTe detectors
    Carini, G. A.
    Bolotnikov, A. E.
    Camarda, G. S.
    James, R. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 120 - 124
  • [5] Non-uniformity Correction Algorithm for THz Array Detectors in High-Resolution Imaging Applications
    Jintamethasawat, Rungroj
    Thanapirom, Chayut
    Rattanawan, Patharakorn
    Cota, Napat
    Cota, Natcha
    Yi, Chia Jia
    Kasamsook, Kittipong
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2022, 43 (9-10) : 845 - 845
  • [6] Non-uniformity Correction Algorithm for THz Array Detectors in High-Resolution Imaging Applications
    Jintamethasawat, Rungroj
    Thanapirom, Chayut
    Rattanawan, Patharakorn
    Cota, Napat
    Cota, Natcha
    Yi, Chia Jia
    Kasamsook, Kittipong
    JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2020, 41 (08) : 940 - 956
  • [7] Non-uniformity Correction Algorithm for THz Array Detectors in High-Resolution Imaging Applications
    Rungroj Jintamethasawat
    Chayut Thanapirom
    Patharakorn Rattanawan
    Napat Cota
    Natcha Cota
    Chia Jia Yi
    Kittipong Kasamsook
    Journal of Infrared, Millimeter, and Terahertz Waves, 2020, 41 : 940 - 956
  • [8] HIGH-RESOLUTION X-RAY-SCATTERING MEASUREMENTS
    ZOMBECK, MV
    BRAUNINGER, H
    ONDRUSCH, A
    PREDEHL, P
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 316 : 174 - 186
  • [9] SILICON CARBIDE MICROSTRIP DETECTORS FOR HIGH RESOLUTION X-RAY SPECTROSCOPY
    Bertuccio, Giuseppe
    Puglisi, Donatella
    Lanzieri, Claudio
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 653 - 657
  • [10] Using direct illumination CCDs as high-resolution area detectors for X-ray scattering
    Livet, F
    Bley, F
    Mainville, J
    Caudron, R
    Mochrie, SGJ
    Geissler, E
    Dolino, G
    Abernathy, D
    Grübel, G
    Sutton, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 451 (03): : 596 - 609