A Bio-Impedance Readout IC with Frequency Sweeping from 1k-to-1MHz for Electrical Impedance Tomography

被引:0
|
作者
Ha, Hyunsoo [1 ]
Konijnenburg, Mario [1 ]
Lukita, Budi [1 ]
van Wegberg, Roland [1 ]
Xu, Jiawei [1 ]
van den Hoven, Richard [1 ]
Lemmens, Marijn [2 ]
Thoelen, Ronald [2 ,3 ]
Van Hoof, Chris [3 ,4 ]
Van Helleputte, Nick [3 ]
机构
[1] Imec Holst Ctr, Eindhoven, Netherlands
[2] Hasselt Univ, Hasselt, Belgium
[3] IMEC, Leuven, Belgium
[4] Katholieke Univ Leuven, Leuven, Belgium
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a bio-impedance (BIOZ) readout IC for electrical impedance tomography (EIT). The IC includes a complete readout channel for impedance characterization at various frequencies ranging from 1k-to-1MHz, an input multiplexer and a programmable digital controller enabling multi-frequency impedance scanning from multiple locations. To relax the bandwidth requirements of the readout channel, pre-demodulation before the IA is employed. A fast channel settling mechanism (<1ms) allows quick switching between frequencies enabling a fast imaging speed. Dynamic element matching (DEM) in the current generation and chopping in the readout front-end are adopted to mitigate 1/f noise resulting in a noise floor of 38.4m Omega RMS. This IC, fabricated in 0.18 mu m, consumes 18.7 mu W and 63 mu W in the readout front-end and the current generator (CG), respectively. By means of in-vitro and in-vivo testing its effectivity for EIT is demonstrated.
引用
收藏
页码:C174 / C175
页数:2
相关论文
共 50 条
  • [21] COMPLEX BIOELECTRIC IMPEDANCE MEASUREMENT SYSTEM FOR THE FREQUENCY-RANGE FROM 5 HZ TO 1 MHZ
    ACKMANN, JJ
    ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (02) : 135 - 146
  • [22] ELECTRICAL IMPEDANCE OF POTATO TUBERS IN 1 TO 100 KHZ FREQUENCY RANGE
    WHITE, GM
    MARTIN, DC
    AGRICULTURAL ENGINEERING, 1969, 50 (10): : 597 - &
  • [23] Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging
    Oh, Tong In
    Koo, Hwan
    Lee, Kyung Heon
    Kim, Sang Min
    Lee, Jeehyun
    Kim, Sung Wan
    Seo, Jin Keun
    Woo, Eung Je
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (03) : 295 - 307
  • [24] Admittivity imaging from multi-frequency micro-electrical impedance tomography
    Ammari, Habib
    Giovangigli, Laure
    Nguyen, Loc Hoang
    Seo, Jin-Keun
    JOURNAL OF MATHEMATICAL ANALYSIS AND APPLICATIONS, 2017, 449 (02) : 1601 - 1618
  • [25] A 0.5-V Sub-10-μW 15.28-mΩ/√Hz Bio-Impedance Sensor IC With Sub-1° Phase Error
    Kim, Kwantae
    Kim, Ji-Hoon
    Gweon, Surin
    Kim, Minseo
    Yoo, Hoi-Jun
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2020, 55 (08) : 2161 - 2173
  • [26] Contactless Bio-Impedance Monitoring Technique for Brain Cryosurgery in a 3D Head Model1
    Sharon Zlochiver
    Moshe Rosenfeld
    Shimon Abboud
    Annals of Biomedical Engineering, 2005, 33 : 1133 - 1133
  • [27] An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz
    Kim, Dan Bee
    Lee, Hyung Kew
    Kim, Wan-Seop
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (02)
  • [28] Image reconstruction methods for electrical impedance tomography on SUT-1 system
    Soleimani, M
    Movafeghi, A
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2252 - 2255
  • [29] The ACE1 Thoracic Electrical Impedance Tomography System for Ventilation and Perfusion
    Mellenthin, Michelle M.
    Mueller, Jennifer L.
    Leon Bueno de Camargo, Erick Dario
    de Moura, Fernando Silva
    Hamilton, Sarah J.
    Lima, Raul Gonzalez
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 4073 - 4076
  • [30] A modified L1/2 regularization algorithm for electrical impedance tomography
    Fan, Wenru
    Wang, Chi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (01)