摘要
The modern power systems include a larger number of more dispersed and smaller power generating sources, which are slowly replacing larger and more concentrated power sources. The objective of this paper is to analyse the replacement of nuclear power plant with wind power plants to compare both cases from the viewpoints of power system reliability. The load diagram and the variability of the power plants, whose power depend on the environmental parameters with the time is considered. This paper is focused on the loss of load expectation. The upgraded method considers plant power as a function of the time instead of its nominal power. Initial real power system model consists of twelve power plants including one nuclear power plant. This plant is then replaced by three wind power plants with their total power five times larger than the power of the nuclear power plant. A comparison of reliability in terms of comparing the loss of load expectation is performed using the real weather data for one calendar year. The results show that the replacement of the nuclear power plant with several wind power plants with wind power capacity five times larger than the nuclear power capacity causes a decrease of the power system reliability.
引用
收藏
页码:455 / 464
页数:10
相关论文
共 50 条
  • [41] Interaction of large wind power generation plants with the power system
    Erlich, I.
    Shewarega, F.
    FIRST INTERNATIONAL POWER & ENERGY CONFERENCE (PECON 2006), PROCEEDINGS, 2006, : 12 - 18
  • [42] PENETRATION AND INTEGRATION OF WIND POWER PLANTS INTO LITHUANIAN POWER SYSTEM
    Deksnys, R.
    Staniulis, R.
    OIL SHALE, 2009, 26 (03) : 319 - 330
  • [43] Power system islanding operation support by wind power plants
    Balram, Pavan
    Ullah, Nayeem. R.
    Anh Tuan Le
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [44] Study of operator reliability in nuclear power plants
    YANG Mengzhuo
    2. Material Physics Department
    3
    4. Engineering Physics Department
    Chinese Science Bulletin, 1997, (19) : 1585 - 1590
  • [45] Study of operator reliability in nuclear power plants
    Yang, MZ
    Gao, J
    Zhao, BQ
    Huang, XR
    Shen, ZP
    CHINESE SCIENCE BULLETIN, 1997, 42 (19): : 1585 - 1590
  • [46] The Reliability of the System with Wind Power Generation
    Melkior, Urbanus F.
    Cernan, Martin
    Mueller, Zdenek
    Tlusty, Josef
    Kasembe, Andrew G.
    2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 148 - 153
  • [47] Reliability evaluation of distribution system considering wind power effect
    Su, Ao-Xue
    Fan, Ming-Tian
    Li, Zhong-Lai
    Liu, Wei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2013, 41 (01): : 90 - 95
  • [48] Reliability Evaluation of Wind and PV Energy Penetrated Power System
    Lalitha, M. Padma
    Reddy, P. Harshavardhan
    Naidu, P. Janardhana
    2014 3RD INTERNATIONAL CONFERENCE ON RELIABILITY, INFOCOM TECHNOLOGIES AND OPTIMIZATION (ICRITO) (TRENDS AND FUTURE DIRECTIONS), 2014,
  • [49] Evaluation and Design Tools for the Reliability of Wind Power Converter System
    Ma, Ke
    Zhou, Dao
    Blaabjerg, Frede
    JOURNAL OF POWER ELECTRONICS, 2015, 15 (05) : 1149 - 1157
  • [50] Evaluation of the Reliability of Wind Power Generation in a Passive Redundant System
    Imran, Shaik Abdur Rehman
    Al Muhaini, Mohammad
    2015 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2015,