Predictions of reversed-phase gradient elution LC separations supported by QSRR

被引:13
|
作者
Baczek, Tomasz [1 ,2 ]
Bodzioch, Karolina [1 ]
Michalska, Elzbieta [1 ]
Kaliszan, Roman [1 ]
机构
[1] Med Univ Gdansk, Dept Biopharmaceut & Pharmacodynam, Hallera 107, PL-80416 Gdansk, Poland
[2] Nicholas Copernicus Univ Torun, Coll Med, Dept Med Chem, PL-85094 Bydgoszcz, Poland
关键词
column liquid chromatography; quantitative structure-retention relationships; linear solvent strength model; prediction of retention; gradient elution;
D O I
10.1365/s10337-008-0674-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Previous studies demonstrated that quantitative structure-retention relationships (QSRR) combined with the linear solvent strength (LSS) model allow for prediction of gradient reversed-phase liquid chromatography retention time for any analyte of a known molecular structure under defined LC conditions. A QSRR model derived at the selected gradient time and at the same gradient time was tested. The aim the present study was to evaluate the accuracy of QSRR predictions used during the predictions of LC gradient retention times with variable gradient times. For this purpose, predictions of retention times at two gradient times were used to find the optimal, different gradient times. In the first step, experimental retention data for the model set of analytes were used to derive appropriate QSRR models at two gradient times. These QSRR models were further used to predict gradient retention times for another set of testing analytes at the two selected above gradient times. Then, applying linear solvent-strength (LSS) theory, the predicted retention times for test analytes were used to find other optimal gradient times for those analytes. Satisfactory predictions of gradient retention times for test analytes were obtained at gradient times different from those applied for model analytes.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [21] Column equilibration effects in gradient elution in reversed-phase liquid chromatography
    Pappa-Louisi, A.
    Nikitas, P.
    Agrafiotou, P.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 97 - 107
  • [22] Retention models for isocratic and gradient elution in reversed-phase liquid chromatography
    Nikitas, P.
    Pappa-Louisi, A.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (10) : 1737 - 1755
  • [23] Optimizing peak capacity of peptides in reversed-phase gradient elution chromatography
    Wang, Xiaoli
    Stoll, Dwight R.
    Carr, Peter W.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U191 - U191
  • [24] ANALYSIS OF METHANOL FOR REVERSED-PHASE GRADIENT ELUTION LIQUID-CHROMATOGRAPHY
    SPINGARN, NE
    GARVIEGOULD, CT
    VUOLO, LL
    ANALYTICAL CHEMISTRY, 1981, 53 (03) : 565 - 566
  • [25] Optimisation technique for stepwise gradient elution in reversed-phase liquid chromatography
    Nikitas, P
    Pappa-Louisi, A
    Papachristos, K
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) : 283 - 289
  • [26] GRADIENT ELUTION IN LIQUID-CHROMATOGRAPHY .10. RETENTION CHARACTERISTICS IN REVERSED-PHASE GRADIENT ELUTION CHROMATOGRAPHY
    JANDERA, P
    CHURACEK, J
    SVOBODA, L
    JOURNAL OF CHROMATOGRAPHY, 1979, 174 (01): : 35 - 50
  • [27] Effects of the gradient profile on the production rate in reversed-phase gradient elution overloaded chromatography
    Jandera, P
    Komers, D
    Guiochon, G
    JOURNAL OF CHROMATOGRAPHY A, 1997, 760 (01) : 25 - 39
  • [28] Ghost Peak Investigation in a Reversed-Phase Gradient LC System
    Sadikin, Silvia
    Zhang, Dee Dee
    Inloes, Roger
    Redkar, Sanjeev
    LC GC EUROPE, 2011, 24 (05) : 252 - +
  • [29] Ghost Peak Investigation in a Reversed-Phase Gradient LC System
    Sadikin, Silvia
    Zhang, Dee Dee
    Inloes, Roger
    Redkar, Sanjeev
    LC GC NORTH AMERICA, 2011, 29 (05) : 394 - +
  • [30] Method to predict the bandwidth of elution profile under the linear gradient elution in reversed-phase HPLC
    Lee, Ju Weon
    Row, Kyung Ho
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (02) : 221 - 230