The simulation study of the short circuit in no load conditions of the large turbine generator

被引:0
|
作者
Tong, XS [1 ]
Li, WL [1 ]
Sun, YT [1 ]
Li, GF [1 ]
Zhang, CL [1 ]
机构
[1] Harbin Inst Large Elect Machinery, Harbin 150040, Peoples R China
来源
System Simulation and Scientific Computing, Vols 1 and 2, Proceedings | 2005年
关键词
turbine generator; short circuit in no-load condition; simulation;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The simulation model of the large turbine generator system in transient conditions is set up by based on software SIMSEN in this paper. The effects of the electromagnetic system of machine, mechanical system and elements of power system are considered in the model. According to the simulation for the short circuit of a 650MW turbine generator in no-load conditions, some short-circuit characteristic curves such as stator current, field current, electromagnetic torque and axis torque curves with time of the generator in various terminal voltages are obtained. At the same time, it also provides a effective and shortcut means.
引用
收藏
页码:815 / 819
页数:5
相关论文
共 50 条
  • [31] Estimation of Short Circuit Capability of Generator Circuit Breaker For a Generator Fed Fault
    Chanda, K.
    Parthasarathi, R.
    Holla, S.
    2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 352 - 355
  • [32] Experimental study on the load monitoring for a 4 pad tilting-pad bearing in large turbine-generator sets
    Yang, ZJ
    Cong, H
    Xie, YB
    PROCEEDINGS OF THE IC-HBRSD'97, 1997, : 425 - 428
  • [33] Torsional Moments in Turbine and Generator Shafts during Short Circuits, Fault Synchronization and Short Circuit Cut-Off.
    Boelderl, Paul
    Kulig, Tadeusz
    Lambrecht, Dietrich
    Elektrotechnische Zeitschrift Ausgabe A, 1975, 96 (04): : 164 - 171
  • [34] A large-eddy simulation study of horizontal axis tidal turbine in different inflow conditions
    Hu, Qiuhao
    Li, Ye
    Di, Yujia
    Chen, Jianwei
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2017, 9 (06)
  • [35] Simulation in the combustor for gas turbine generator
    Furuhata, T.
    Nogami, H.
    Tanno, S.
    Miura, T.
    Miyabuti, Y.
    Abe, T.
    Sugimoto, T.
    Ureshi, K.
    Proceedings of the World Conference on Experimental Heat Transfer, Fluid Mechanics, and Thermodynamics, 1991,
  • [36] STEAM TURBINE GENERATOR DESIGN FOR INCREASED RATINGS - STANDARDIZATION OF LARGE TURBINE GENERATORS IS COMPLICATED BY OPERATING-CONDITIONS
    HOSSLI, W
    HIEBLER, H
    ELECTRICAL REVIEW, 1972, 191 (17): : 551 - &
  • [37] GENERATOR CIRCUIT-BREAKER TRANSIENT RECOVERY VOLTAGE IN MOST SEVERE SHORT-CIRCUIT CONDITIONS.
    Ruoss, E.
    1600,
  • [38] A novel method for identifying large steam turbine-generator parameters by load rejection test
    Kang, E
    Sun, L
    Li, B
    Yu, CS
    ICEMS 2005: PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2005, : 119 - 123
  • [39] Short-Circuit Fault Simulations in an HTS Wind Generator With Different Mechanical Conditions
    Huang, Zhen
    Zhao, Anfeng
    Huang, Xinbin
    Zhu, Binbin
    Jiang, Yudong
    Jin, Zhijian
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
  • [40] Dynamic simulation of a gas turbine for heat recovery at varying load and environment conditions
    Gou, Xiang
    Zhang, Han
    Li, Guangyao
    Cao, Yuhao
    Zhang, Qiyan
    APPLIED THERMAL ENGINEERING, 2021, 195