Peripheral lung volume reduction improved early graft function in severe size mismatched living donor lobar lung transplantation

被引:17
|
作者
Oto, T [1 ]
Date, H [1 ]
Hayama, M [1 ]
Ando, A [1 ]
Shimizu, N [1 ]
机构
[1] Okayama Univ, Sch Med, Dept Canc & Thorac Surg, Okayama 7008558, Japan
关键词
D O I
10.1016/j.transproceed.2005.10.119
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Lung transplantation from adults to infants or small children is still challenging because of concerns related to size disparity. Peripheral lung volume reduction for size disparity in cadaveric donor lung transplantation has been widely performed; however, little is known about the efficacy and the functional outcomes of downsizing the implanted lobes for severe size disparity in living donor lobar lung transplantation. Methods. Thirteen size-mismatched (donor/recipient lung volume ratio > 2.82) bilateral living donor lobar lung transplants were performed with (reduction group, n = 6) or without (no-reduction group, n = 7) peripheral lung volume reduction. Results. On spontaneous respiration, PaO2 in the reduction group was significantly higher than that in the no-reduction group (P < .01) and PaCO2 in the reduction group was significantly lower than that in the no-reduction group (P < .001). Pulmonary vascular resistance in the reduction group remained significantly lower than that in the no-reduction group throughout the assessment periods after chest closure (P < .05). Peak airway pressure in the no-reduction group increased significantly at the time of chest closure (P < .001) and remained significantly higher than that in the reduction group throughout the assessment period on mechanical ventilation (P < .01). The percentage of weight reduced from implanted grafts significantly correlated with donor/recipient lung volume ratio (r = 0.82, P < .05). Conclusions. Peripheral lung volume reduction is useful to improve early graft function in severe size mismatched experimental living donor lobar lung transplantation. The technique might allow for further flexibility in donor size and for increasing the donor pool for small recipients.
引用
收藏
页码:4515 / 4521
页数:7
相关论文
共 50 条
  • [31] Comparison of living-donor lobar lung transplantation and cadaveric lung transplantation for pulmonary hypertension
    Kayawake, Hidenao
    Tanaka, Satona
    Yamada, Yoshito
    Baba, Shiro
    Kinoshita, Hideyuki
    Yamazaki, Kazuhiro
    Ikeda, Tadashi
    Minatoya, Kenji
    Yutaka, Yojiro
    Hamaji, Masatsugu
    Ohsumi, Akihiro
    Nakajima, Daisuke
    Date, Hiroshi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 63 (04)
  • [32] Outcome of living-donor lobar lung transplantation using a single donor
    Date, Hiroshi
    Shiraishi, Takeshi
    Sugimoto, Seiichiro
    Shoji, Tsuyoshi
    Chen, Fengshi
    Hiratsuka, Masafumi
    Aoyama, Akihiro
    Sato, Masaaki
    Yamane, Masaomi
    Iwasaki, Akinori
    Miyoshi, Shinichiro
    Bando, Toru
    Oto, Takahiro
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (03): : 710 - 715
  • [33] Chronic Lung Allograft Dysfunction After Bilateral Living Donor Lobar Lung Transplantation
    Miyoshi, K.
    Oto, T.
    Sugimoto, S.
    Yamane, M.
    Miyoshi, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S45 - S45
  • [34] Living-donor lobar lung transplantation for pulmonary hypertension: living on the edge?
    Van Raemdonck, Dirk
    Vos, Robin
    Verleden, Geert M.
    Ceulemans, Laurens J.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 63 (04)
  • [35] Modified Low-Flow Ultrafiltration Ameliorates Hemodynamics and Early Graft Function and Reduces Blood Loss in Living-Donor Lobar Lung Transplantation
    Kotani, Yasuhiro
    Honjo, Osami
    Goto, Keiji
    Fujita, Yasufumi
    Ito, Atsushi
    Nakakura, Mahito
    Kawada, Masaaki
    Sano, Shunji
    Kotani, Kazutoshi
    Date, Hiroshi
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (04): : 340 - 346
  • [36] Modified 'Low-Flow' ultraftitration ameliorates Hemodynamics and early graft function and reduces blood loss in living-donor lobar lung transplantation
    Kotani, Y.
    Honjo, O.
    Goto, K.
    Sano, S.
    Date, H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S80 - S81
  • [37] Long-term improvement in graft function after bilateral living-donor lobar lung transplantation in adults and pediatrics
    Yamane, M.
    Date, H.
    Okazaki, M.
    Toyooka, S.
    Sano, Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (02): : S114 - S114
  • [38] Living donor lobar lung transplantation improves survival following lung re-transplantation in children
    Kozower, B. D.
    Sweet, S. C.
    de la Morena, M.
    Schuler, P.
    Guthrie, T. J.
    Patterson, G. A.
    Gandhi, S. K.
    Huddleston, C. B.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02): : S65 - S65
  • [39] Pulmonary arterioplasty for the remaining arterial stump of the donor and the arterial cuff of the donor graft in living-donor lobar lung transplantation
    Chen, Fengshi
    Miwa, Senri
    Bando, Toru
    Date, Hiroshi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (05) : E138 - E139
  • [40] Long-term improvement in pulmonary function after living donor lobar lung transplantation
    Yamane, Masaomi
    Date, Hiroshi
    Okazaki, Megumi
    Toyooka, Shinichi
    Aoe, Motoi
    Sano, Yoshifumi
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (07): : 687 - 692