Microchannel plates containing neutron absorbing elements such as boron and gadolinium in the bulk glass are used as the sensing element in high spatial resolution, high rate neutron imaging systems. In this paper we describe one such device, using both B-10 and natural Gd, which employs cross delay line signal readout, with time-of-flight capability. This detector has a measured spatial resolution under 40 mu m FWHM, thermal neutron efficiency of 19%, and has recorded rates in excess of 500 kHz. A physical and functional description is presented, followed by a discussion of measurements of detector performance and a brief survey of some practical applications.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 50 条
  • [41] FPGA implementation of a delay-line readout system for a particle detector
    Seferiadis, G
    Pouchet, M
    Gough, MP
    MEASUREMENT, 2006, 39 (01) : 90 - 99
  • [42] Study of Delay-line Readout for Boron Coated Straw detector
    Yu, Hao
    Gong, Hui
    Wang, Yongqiang
    Wang, Xuewu
    Li, Jianmin
    Li, Yuanjing
    Kang, Kejun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [43] Optimal calculation of detection efficiency for thermal neutron sensitive microchannel plate
    Wang Sheng
    Li Hang
    Cao Chao
    Wu Yang
    Huo He-Yong
    Tang Bin
    ACTA PHYSICA SINICA, 2015, 64 (10)
  • [44] Multiple hit read-out of a microchannel plate detector with a three-layer delay-line anode
    Jagutzki, O
    Cerezo, A
    Czasch, A
    Dörner, R
    Hattass, M
    Huang, M
    Mergel, V
    Spillmann, U
    Ullmann-Pfleger, K
    Weber, T
    Schmidt-Böcking, H
    Smith, G
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 850 - 854
  • [45] An efficient and cost-effective microchannel plate detector for slow neutron radiography
    Wiggins, B. B.
    Vadas, J.
    Bancroft, D.
    deSouza, Z. O.
    Huston, J.
    Hudan, S.
    Baxter, D., V
    deSouza, R. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 891 : 53 - 57
  • [46] ABSOLUTE AND ANGULAR EFFICIENCIES OF A MICROCHANNEL-PLATE POSITION-SENSITIVE DETECTOR
    GAO, RS
    GIBNER, PS
    NEWMAN, JH
    SMITH, KA
    STEBBINGS, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (11): : 1756 - 1759
  • [47] CHARACTERIZATION OF A FAST, SENSITIVE GAMMA-DETECTOR UTILIZING MICROCHANNEL PLATE PHOTOMULTIPLIER
    KRUSE, HW
    HOCKER, LP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 387 - 389
  • [48] Stacked orthogonal serpentine delay lines with vias for two-dimensional microchannel plate readout
    Lampton, M
    Marckwordt, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (12): : 4611 - 4619
  • [49] A multiplex readout method for position sensitive boron coated straw neutron detector
    Yu, Hao
    Gong, Hui
    Li, Jianmin
    Wang, Yongqiang
    Wang, Xuewu
    Li, Yuanjing
    Kang, Kejun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 797 : 324 - 329
  • [50] Development of large area cross strip readout technologies for microchannel plate UV detectors
    Curtis, Travis
    Siegmund, Oswald W.
    McPhate, Jason B.
    Nell, Nicholas J.
    Vallerga, John V.
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY XI, 2024, 13103