摘要
The study of switching transient overvoltages in HV transmission lines is fundamental for insulation coordination purposes. It is well known that, in general, the poles of a 3-phase circuit breaker do not close at the same time, but in a sequential manner. An efficient way to take this into account for simulation purposes consists of performing several switching simulations with random closing times for each phase (and different for each event). This is known as Monte Carlo method. Evidently, the precision of this method is highly dependent on the software and transmission model applied for the study. In this work, the accuracy of several transmission line models included in two widely used transient simulation programs (ATP and PSCAD/EMTDC) is analyzed and compared in a statistical manner, by means of a Monte Carlo study of switching transients for two different tower configurations (horizontal and vertical disposition of conductors). For that purpose, a frequency domain method based on the numerical Laplace transform and the superposition principle is used as base solution.
引用
收藏
页码:1036 / 1046
页数:11
相关论文
共 50 条
  • [31] Implementation of Modal Domain Transmission Line Models in the ATP Software
    Leon Colqui, Jaimis Sajid
    Timana Eraso, Luis Carlos
    Caballero, Pablo Torrez
    Pissolato Filho, Jose
    Kurokawa, Sergio
    IEEE ACCESS, 2022, 10 : 15924 - 15934
  • [32] Time Reversal Applied to the Time Domain Response of a CRLH Transmission Line
    Dyab, Walid M.
    Sarkar, Tapan K.
    Salazar-Palma, Magdalena
    IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2012, 22 (12) : 609 - 611
  • [33] Time-domain models for pneumatic transmission lines
    Franco, W
    Sorli, M
    POWER TRANSMISSION AND MOTION CONTROL, 2004, : 257 - 269
  • [34] Direct frequency domain computation of transmission line transients due to switching operations
    Semlyen, Adam
    Ramirez, Abner
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2255 - 2261
  • [35] Direct Frequency Domain Computation of Transmission Line Transients Due to Switching Operations
    Ramlrez, Abner
    Semlyen, Adam
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2795 - 2795
  • [36] Statistical study for switching processes in compensated UHV transmission systems
    Hamed, M
    Esmail, D
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1997, 144 (03) : 237 - 241
  • [37] FAULT SURGE VERSUS SWITCHING SURGE A STUDY OF TRANSIENT OVERVOLTAGES CAUSED BY LINE-TO-GROUND FAULTS
    KIMBARK, EW
    LEGATE, AC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (09): : 1762 - &
  • [38] Integrating Statistical Response Time Models in Architectural Performance Models
    Eismann, Simon
    Grohmann, Johannes
    Walter, Juergen
    von Kistowski, Joakim
    Kounev, Samuel
    2019 IEEE INTERNATIONAL CONFERENCE ON SOFTWARE ARCHITECTURE (ICSA), 2019, : 71 - 80
  • [39] An accurate time domain interconnect model of transmission line networks
    Yu, QJ
    Kuh, ES
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 1996, 43 (03): : 200 - 208
  • [40] Time-Domain Analysis of a Lossy Nonuniform Transmission Line
    Jeong, Jaehoon
    Nevels, Robert
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2009, 56 (02) : 157 - 161