Study on test distance between EUT and antenna for radiated immunity test in close proximity to equipment

被引:0
|
作者
Takaya, Kazuhiro [1 ]
Nakamura, Naomichi [1 ]
Hiroshima, Yoshiharu [1 ]
Okugawa, Yuichiro [1 ]
机构
[1] Nippon Telegraph & Tel Corp, Network Technol Labs, Musashino, Tokyo, Japan
关键词
radiated immunity test in close proximity; wireless device; test distance; test signal;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
IEC Technical Committee TC77 Subcommittee SC77B is studying a radiated immunity test in close proximity to equipment for incorporation into a new IEC standard, IEC 61000-4-39. Although IEC 61000-4-39 2nd CD, which was published in July 2015, requires that the test distance between equipment under test (EUT) and a test antenna be 100 +/- 5 mm at a frequency range of 385 MHz to 6 GHz, whether this test distance is valid for such a wide frequency range requires additional study. This paper attempts to validate the test distance for a radiated immunity test under the assumption that a 2.4 GHz-band wireless device is used in close proximity to telecommunication equipment. Three antenna candidates were used to examine how the size of the uniform electric field strength to the EUT varies when the test distance is changed. We also examined how the electric field strength near the test antenna affects the appropriate test distance for the case where the side surfaces of the EUT are shielded by metallic conductors. Furthermore, we studied how varying test signal types in a radiated immunity test affects the appropriate test distance and consequently the EUT.
引用
收藏
页码:285 / 289
页数:5
相关论文
共 50 条
  • [21] A Novel Segmentation Approach for Modeling of Radiated Emission and Immunity Test Setups
    Reddy, V. S.
    Kralicek, Peter
    Hansen, Jan
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2017, 59 (06) : 1781 - 1790
  • [22] A guide for choosing essential EMC immunity test equipment
    O'Shea, P
    EE-EVALUATION ENGINEERING, 1998, 37 (04): : 68 - +
  • [23] Study on Execution Distance Estimation for Field Test Cases of On-board Equipment
    Zhang Y.
    Yuan Y.
    Rao C.
    Guo J.
    Tiedao Xuebao/Journal of the China Railway Society, 2022, 44 (07): : 55 - 62
  • [24] Study of the test equipment for UPFC
    Tang, Aihong
    Zhu, Pengcheng
    Cheng, Shijie
    Sun, Haishun
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2006, 21 (06): : 122 - 126
  • [25] New radiated immunity test method using fields of low speed rotation
    Murano, K
    Kami, Y
    1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - SYMPOSIUM RECORD, VOLS 1 AND 2, 1998, : 730 - 733
  • [26] A Correlation Study between the Novel Stereo Vision Perception Test (StereoViPer Test) and the Frisby Test for Measuring Distance Stereopsis
    Tong, Jie
    Paulus, Jan
    Eskofier, Bjoern
    Schmidt, Michael
    Lochmann, Matthias
    Michelson, Georg
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [27] SAR TRiM Level Radiated Output Verification at Compact Antenna Test Facility
    Kumar, Abhishek
    Midhun, M.
    Govinda, Senapati
    Agarwal, Neha
    Subbaraya, Sastry C. V. R.
    10TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTING AND COMMUNICATION TECHNOLOGIES, CONECCT 2024, 2024,
  • [28] TEST AND FLIGHT EVALUATION OF PRECISION DISTANCE MEASURING EQUIPMENT.
    Becker, Klaus
    Mueller, Albrecht
    Hurrass, K.
    Airport forum, 1986, 16 (05): : 71 - 72
  • [29] Linkage analysis using geographical proximity: a test of the efficacy of distance measures
    Haginoya, Shumpei
    Hanayama, Aiko
    Koike, Tamae
    JOURNAL OF CRIMINOLOGICAL RESEARCH POLICY AND PRACTICE, 2021, 7 (01) : 51 - 62
  • [30] Study on modularization of automatic test equipment
    Jia, ZJ
    Chen, GS
    Long, YX
    Wang, XM
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 1, 2005, : 519 - 522