Design of a cost-effective weighing facility for PM2.5 quality assurance

被引:7
|
作者
Carlton, AG [1 ]
Teitz, A [1 ]
机构
[1] US EPA, Monitoring & Assessement Branch, Div Environm Sci & Assessment, Edison, NJ USA
来源
关键词
D O I
10.1080/10473289.2002.10470802
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The U.S. Environmental Protection Agency (EPA) Quality Assurance (QA) Guidance Document 2.12: Monitoring PM2.5 in Ambient Air Using Designated Reference or Class I Equivalent Methods' (Document 2.12) requires conditioning of PM2.5 filters at 20-23 degreesC and 30-40% relative humidity (RH) for 24 hr prior to gravimetric analysis. Variability of temperature and humidity may not exceed +/-2 degreesC and +/-5% RH during the conditioning period. The quality assurance team at EPA Region 2's regional laboratory designed a PM2.5 weighing facility that operates well within these strict performance requirements. The traditional approach to meeting the performance requirements of Document 2.12 for PM2.5 filter analysis is to build a walk-in room, with costs typically exceeding $100,000. The initial one-time capital cost for the laboratory at EPA's Edison, NJ, facility was approximately $24,000. Annual costs [e.g., National Institute of Standards and Technology (NIST) recertifications and nitrogen replacement cylinders used for humidity control] are approximately $500. The average 24-hr variabilities in temperature and RH in the Region 2 weighing chamber are small, +/-0.2 degreesC and +/-0.8% RH, respectively. The mass detection limit for the PM2.5 weighing system of 47-mm stretched Teflon (lab blank) filters is 6.3 mug. This facility demonstrates an effective and economical example for states and other organizations planning PM2.5 weighing facilities.
引用
收藏
页码:506 / 510
页数:5
相关论文
共 50 条
  • [31] COST-EFFECTIVE FURNACE DESIGN
    ROBERTS, D
    AMERICAN CERAMIC SOCIETY BULLETIN, 1983, 62 (08): : 876 - 876
  • [32] Cost-Effective Mission Assurance Engineering Through Simulation
    Siil, Karl
    Rubin, Aviel
    Elder, Matthew
    Dahbura, Anton
    Green, Matthew
    Watkins, Lanier
    2021 IEEE INTERNATIONAL CONFERENCE ON INTERNET OF THINGS AND INTELLIGENCE SYSTEMS (IOTAIS), 2021, : 67 - 72
  • [33] Modeling approach for emissions reduction of primary PM2.5 and secondary PM2.5 precursors to achieve the air quality target
    Chen, Tu-Fu
    Chang, Ken-Hui
    Tsai, Chang-You
    ATMOSPHERIC RESEARCH, 2017, 192 : 11 - 18
  • [34] Significance of PM2.5 Air Quality at the Indian Capital
    Sahu, Shovan Kumar
    Kota, Sri Harsha
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (02) : 588 - 597
  • [35] Air Quality Modeling via PM2.5 Measurements
    Zhou, Min
    Goh, Thong Ngee
    THEORY AND PRACTICE OF QUALITY AND RELIABILITY ENGINEERING IN ASIA INDUSTRY, 2017, : 197 - 210
  • [36] Air quality monitoring design:: Optimization of PM2.5 networks using satellite observations
    Saisana, M
    Sarigiannis, D
    Chaloulakou, A
    Spyrellis, N
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOLS A AND B, 2001, : 747 - 754
  • [37] On the distribution of low-cost PM2.5 sensors in the US: demographic and air quality associations
    deSouza, Priyanka
    Kinney, Patrick L.
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2021, 31 (03) : 514 - 524
  • [38] Mining PM2.5 and Traffic Conditions for Air Quality
    Du, Xu
    Varde, Aparna S.
    2016 7TH INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION SYSTEMS (ICICS), 2016, : 33 - 38
  • [39] Introducing "accountability" in the management of PM2.5 air quality
    Demerjian, K
    Cook, J
    Scheffe, R
    ATMOSPHERIC OBSERVATIONS: HELPING BUILD THE SCIENTIFIC BASIS FOR DECISIONS RELATED TO AIRBORNE PARTICULATE MATTER, 1998, : 27 - 30
  • [40] On the distribution of low-cost PM2.5 sensors in the US: demographic and air quality associations
    Priyanka deSouza
    Patrick L. Kinney
    Journal of Exposure Science & Environmental Epidemiology, 2021, 31 : 514 - 524