Inter-laboratory comparison of different rapid methods for the detection of bacterial contamination in platelet concentrates

被引:16
|
作者
Vollmer, T. [1 ]
Hinse, D. [1 ]
Schottstedt, V. [2 ]
Bux, J. [2 ]
Tapernon, K. [3 ]
Sibrowski, W. [3 ]
Knabbe, C. [1 ]
Dreier, J. [1 ]
机构
[1] Ruhr Univ Bochum, Univ Klin, Inst Lab & Transfus Med, Herz & Diabet Zentrum N Rhein Westfalen, D-32545 Bad Oeynhausen, Germany
[2] DRK Blutspendedienst W, Zentrallabor Hagen, Germany
[3] Univ Klinikum Munster, Inst Transfus Med & Transplantat Immunol, Munster, Germany
关键词
BactiFlow; nucleic acid amplification techniques; Pan Genera detection; platelet bacteria screening; rapid methods; 6 YEARS EXPERIENCE; TECHNOLOGY; PCR;
D O I
10.1111/j.1423-0410.2011.01572.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Bacterial contamination of platelet concentrates still represents a major risk in transfusion medicine, and a variety of screening methods have been available to improve the safety of PCs. In the present study, the analytical quality of three different rapid screening methods (BactiFlow flow cytometry, Pan Genera Detection Assay, 23S rRNA RT-PCR) was evaluated in an inter-laboratory comparison in three different German blood services. Methods Samples were inoculated with different bacteria [Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli (two strains), Klebsiella pneumoniae (two strains), Enterobacter aerogenes (one strain), Serratia marcescens (one strain)] at different counts (4.5 X 1034.5 X 108 CFU/ml) alternating with negative samples in one transfusion facility. Samples were blinded with a random order for each screening method, shipped to partners and analysed immediately after receipt with different rapid screening methods. Results The inter-laboratory comparison revealed that the BactiFlow assay and 23S rRNA RT-PCR-screening detected all samples correctly (positive: 12/12, negative: 8/8). The Pan Genera Detection Assay test detected only four of the positive samples. Four of the non-detected positive samples were below the assays detection limit. Another four inoculated samples with comparatively high bacteria counts were detected false negative (E. coli (two strains): 9.87 X 105 and 2.10 X 107 CFU/ml, respectively, K. pneumoniae: 4.79 X 106 CFU/ml, S. aureus: 6.03 X 105 CFU/ml). All rapid screening methods revealed no false-positive results. Conclusions Both BactiFlow and 23S rRNA RT-PCR demonstrated a high sensitivity to detecting bacterial contamination in PCs. The Pan Genera Detection Assay had some shortcomings regarding sensitivity, especially for the detection of Gram-negative strains.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] STUDIES OF ONE INVASIVE AND 2 NONINVASIVE METHODS FOR DETECTION OF BACTERIAL-CONTAMINATION OF PLATELET CONCENTRATES
    HOGMAN, CF
    GONG, J
    VOX SANGUINIS, 1994, 67 (04) : 351 - 355
  • [22] Inter-laboratory comparison of routine autoantibody detection methods for autoimmune neuropathies and myasthenia gravis
    Martinez-Martinez, Laura
    Lacruz, Anna Calvet
    Querol, Luis
    Cortes-Vicente, Elena
    Pascual, Elba
    Rojas-Garcia, Ricard
    Reyes-Leiva, David
    Alvaro, Yolanda
    Molto, Elisabeth
    Ortiz, Esther
    Gallardo, Eduard
    Juarez, Candido
    Mariscal, Anais
    JOURNAL OF NEUROLOGY, 2024, 271 (07) : 4119 - 4130
  • [23] Problem of bacterial contamination in platelet concentrates
    Mathai, Jaisy
    TRANSFUSION AND APHERESIS SCIENCE, 2009, 41 (02) : 139 - 144
  • [24] Bacterial contamination in platelet concentrates of horses
    Alvarez, M. E.
    Giraldo, C. E.
    Carmona, J. U.
    ARCHIVOS DE MEDICINA VETERINARIA, 2010, 42 (01) : 49 - 56
  • [25] Letter on Bacterial contamination in platelet concentrates
    Harm, S. K.
    Delaney, M.
    Aubuchon, J. P.
    Triulzi, D. J.
    Yazer, M. H.
    VOX SANGUINIS, 2014, 107 (03) : 312 - 312
  • [26] Rapid Detection of Bacterial Contamination of Platelet-Rich Plasma-Derived Platelet Concentrates Using Flow Cytometry
    Lee, Hye Ryun
    Seo, Ji-Weon
    Kim, Mi Jung
    Song, Sang Hoon
    Park, Kyoung Un
    Song, Junghan
    Han, Kyou-Sup
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2012, 42 (02): : 174 - 181
  • [27] Inter-laboratory comparison of methods to measure androstenone in pork fat
    Kragten, S. Ampuero
    Verkuylen, B.
    Dahlmans, H.
    Hortos, M.
    Garcia-Regueiro, J. A.
    Dahl, E.
    Andresen, O.
    Feitsma, H.
    Mathur, P. K.
    Harlizius, B.
    ANIMAL, 2011, 5 (10) : 1634 - 1642
  • [28] Results of an inter-laboratory comparison of methods for quantitative clay analysis
    Ottner, F
    Gier, S
    Kuderna, M
    Schwaighofer, B
    APPLIED CLAY SCIENCE, 2000, 17 (5-6) : 223 - 243
  • [29] Novel methods for detection of platelet bacterial contamination
    Yomtovian, R
    VOX SANGUINIS, 2002, 83 : 129 - 131
  • [30] RAPID DETECTION OF BACTERIAL CONTAMINATION OF PLATELET-RICH PLASMA-DERIVED PLATELET CONCENTRATES USING FLOW CYTOMETRY
    Park, K. U.
    Lee, H. R.
    Seo, J.-W.
    Han, K. S.