Prognostic value of vasodilator response using rubidium-82 positron emission tomography myocardial perfusion imaging in patients with coronary artery disease

被引:5
|
作者
Arasaratnam, Punitha [1 ]
Sadreddini, Masoud [1 ]
Yam, Yeung [1 ]
Kansal, Vinay [1 ]
Dorbala, Sharmila [2 ,3 ]
Di Carli, Marcelo F. [2 ,3 ]
Beanlands, Rob S. [1 ]
Merhige, Michael E. [4 ,5 ,6 ]
Williams, Brent A. [7 ]
Veledar, Emir [8 ]
Min, James K. [9 ,10 ]
Chen, Li [11 ]
Ruddy, Terrence D. [12 ]
Germano, Guido [13 ]
Berman, Daniel S. [13 ]
Shaw, Leslee J. [8 ]
Chow, Benjamin J. W. [1 ,12 ]
机构
[1] Univ Ottawa, Dept Med Cardiol, Inst Heart, 40 Ruskin St, Ottawa, ON K1Y 4W7, Canada
[2] Brigham & Womens Hosp, Div Cardiovasc Med, 75 Francis St, Boston, MA 02115 USA
[3] Brigham & Womens Hosp, Div Nucl Med, 75 Francis St, Boston, MA 02115 USA
[4] Niagara Falls Mem Med Ctr, Dept Cardiol, Buffalo, NY USA
[5] Niagara Falls Mem Med Ctr, Dept Internal Med, Buffalo, NY USA
[6] Niagara Falls Mem Med Ctr, Dept Nucl Med, Buffalo, NY USA
[7] Geisinger Med Ctr, Dept Ctr Hlth Res, Danville, PA 17822 USA
[8] Emory Univ, Sch Med, Dept Med, Atlanta, GA USA
[9] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[10] Weill Cornell Med Coll, Dept Imaging, New York, NY USA
[11] Univ Ottawa, Cardiovasc Res Methods Ctr, Inst Heart, Ottawa, ON, Canada
[12] Univ Ottawa, Dept Radiol, Ottawa, ON, Canada
[13] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
关键词
Positron emission tomography; Heart rate; Blood pressure; Prognosis; All-cause death; HEART-RATE RESPONSE; THERAPEUTIC BENEFIT; HEMODYNAMIC-CHANGES; DIABETES-MELLITUS; CARDIAC DEATH; STRESS; ADENOSINE; CAFFEINE; REGADENOSON; DIPYRIDAMOLE;
D O I
10.1007/s00259-017-3878-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Prognostic value of positron emission tomography (PET) myocardial perfusion imaging (MPI) is well established. There is paucity of data on how the prognostic value of PET relates to the hemodynamic response to vasodilator stress. We hypothesize that inadequate hemodynamic response will affect the prognostic value of PET MPI. Methods and results Using a multicenter rubidium (Rb)-82 PET registry, 3406 patients who underwent a clinically indicated rest/stress PET MPI with a vasodilator agent were analyzed. Patients were categorized as, "responders" [increase in heart rate >= 10 beats per minute (bpm) and decrease in systolic blood pressure (SBP) >= 10 mmHg], "partial responders" (either a change in HR or SBP), and "non-responders" (no change in HR or SBP). Primary outcome was all-cause death (ACD), and secondary outcome was cardiac death (CD). Ischemic burden was measured using summed stress score (SSS) and % left ventricular (LV) ischemia. After a median follow-up of 1.68 years (interquartile range = 1.17-2.55), there were 7.9% (n = 270) ACD and 2.6% (n = 54) CD. Responders with a normal PET MPI had an annualized event rate (AER) of 1.22% (SSS of 0-3) and 1.58% (% LV ischemia = 0). Partial and non-responders had higher AER with worsening levels of ischemic burden. In the presence of severe SSS >= 12 and LV ischemia of >= 10%, partial responders had an AER of 10.79% and 10.36%, compared to non-responders with an AER of 19.4% and 12.43%, respectively. Patient classification was improved when SSS was added to a model containing clinical variables (NRI: 42%, p < 0.001) and responder category was added (NRI: 61%, p < 0.001). The model including clinical variables, SSS and hemodynamic response has good discrimination ability (Harrell C statistics: 0.77 [0.74-0.80]). Conclusion Hemodynamic response during a vasodilator Rb-82 PET MPI is predictive of ACD. Partial and non-responders may require additional risk stratification leading to altered patient management.
引用
收藏
页码:538 / 548
页数:11
相关论文
共 50 条
  • [31] Positron emission tomography rubidium-82 myocardial perfusion imaging in diagnosing uncommon paediatric acute coronary syndrome: a case report
    Abd Razak, Nadiah
    Yusof, Ahmad Khairuddin Md
    Hamid, Khadijah Abdul
    Khor, Phay Phay
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):
  • [32] Effect of proton pump inhibitors on Rubidium-82 gastric uptake using positron emission tomography myocardial perfusion imaging
    Atif H. Alzahrani
    Punitha Arasaratnam
    Samia Massalha
    Ali Alenazy
    Alex Lee
    Owen Clarkin
    Robert A deKemp
    Alomgir Hossain
    Rob S. Beanlands
    Terrence D. Ruddy
    Benjamin J. W. Chow
    Journal of Nuclear Cardiology, 2020, 27 : 1443 - 1451
  • [33] PLANAR IMAGING OF MYOCARDIAL PERFUSION WITH RUBIDIUM-82, A POSITRON EMITTER
    GOLDSMITH, SJ
    COCHAVI, S
    STRASHUN, A
    TRAPPIER, A
    HOROWITZ, SF
    GORLIN, R
    OBRIEN, H
    CIRCULATION, 1980, 62 (04) : 75 - 75
  • [34] Incremental prognostic value of left ventricular ejection fraction assessment over myocardial perfusion imaging: A rubidium-82 positron emission tomography/computed tomography study
    Dorbala, Sharmila
    Hachamovitch, Rory
    Zelmira, Curillova
    Kwong, Raymond Y.
    Di Carli, Marcelo F.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 109A - 109A
  • [35] Positron emission tomography rubidium-82 myocardial perfusion imaging in diagnosing uncommon paediatric acute coronary syndrome: a case report
    Nadiah Abd Razak
    Ahmad Khairuddin Md. Yusof
    Khadijah Abdul Hamid
    Phay Phay Khor
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [36] The value of quantitative myocardial perfusion imaging with positron emission tomography in coronary artery disease
    Wijns, W
    Camici, PG
    HERZ, 1997, 22 (02) : 87 - 95
  • [37] Effect of proton pump inhibitors on Rubidium-82 gastric uptake using positron emission tomography myocardial perfusion imaging
    Alzahrani, Atif H.
    Arasaratnam, Punitha
    Massalha, Samia
    Alenazy, Ali
    Lee, Alex
    Clarkin, Owen
    DeKemp, Robert A.
    Hossain, Alomgir
    Beanlands, Rob S.
    Ruddy, Terrence D.
    Chow, Benjamin J. W.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) : 1443 - 1451
  • [38] Value of SiPM PET in myocardial perfusion imaging using Rubidium-82
    Koenders, S. S.
    van Dalen, J. A.
    Jager, P. L.
    Knollema, S.
    Timmer, J. R.
    Mouden, M.
    Slump, H.
    van Dijk, J. D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 204 - 212
  • [39] Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease?
    Ziadi, Maria C.
    deKemp, Robert A.
    Williams, Kathryn
    Guo, Ann
    Renaud, Jennifer M.
    Chow, Benjamin J. W.
    Klein, Ran
    Ruddy, Terrence D.
    Aung, May
    Garrard, Linda
    Beanlands, Rob S. B.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (04) : 670 - 680
  • [40] Redistribution of myocardial perfusion after coronary sinus reducer implantation demonstrated by rubidium-82 positron emission tomography
    Cheng, Kevin
    Tan, Sian -Tsung
    Wechalekar, Kshama
    Keramida, Georgia
    de Silva, Ranil
    JOURNAL OF NUCLEAR CARDIOLOGY, 2024, 33