Seismic strengthening of low-rise reinforced concrete frame structures with masonry infill walls: Shaking-table test

被引:34
|
作者
Benavent-Climent, A. [1 ]
Ramirez-Marquez, A. [2 ]
Pujol, S. [3 ]
机构
[1] Univ Politecn Madrid, Dept Mech Engn, Madrid 28006, Spain
[2] Univ Granada, Dept Struct Mech, E-18071 Granada, Spain
[3] Purdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
关键词
Masonry infill wall; RC frame; Shaking-table test; Seismic retrofit; Force-displacement model; NONLINEAR BEHAVIOR;
D O I
10.1016/j.engstruct.2018.03.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates experimentally the seismic behavior of reinforced concrete (RC) frames damaged by earthquakes and retrofitted with masonry infill walls. To this end, a 2/5 scale one-bay one story RC frame structure designed only for gravity loads (without seismic design consideration) was built in laboratory. Initially, it was subjected to several shakings to induce a moderate level of damage characterized by a maximum lateral drift ratio of 1.5% and a residual deformation of 0.12%. Next, the RC frame structure was retrofitted with two masonry infill walls oriented in the direction of motion and subjected to four uniaxial seismic simulations. The structure with infills experienced drift ratios of up to about 5% without signs of catastrophic collapse, and retained a reasonable energy dissipation capacity after the walls reached their maximum strength. The maximum drift reached was surprising given the brittleness of masonry. The results of the test open a realm of the possibilities for infill walls as a seismic retrofit solution. Finally, on the basis of experimental data acquired, a model for estimating the force-displacement relationship of the infills is proposed.
引用
收藏
页码:142 / 151
页数:10
相关论文
共 50 条
  • [41] An innovative seismic-resistant steel frame with reinforced concrete infill walls
    Dall'Asta, Andrea
    Leoni, Graziano
    Morelli, Francesco
    Salvatore, Walter
    Zona, Alessandro
    ENGINEERING STRUCTURES, 2017, 141 : 144 - 158
  • [42] Shaking Table Test of Reinforced Concrete Frame-wall Model
    Zhang, Hao
    Li, Bing
    Li, Xu
    Wang, Debin
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 1467 - +
  • [43] The research on shaking table test of reinforced concrete frame strengthened with CFRP
    Wei, WH
    Xiong, YQ
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 1139 - 1144
  • [44] Seismic evaluation of low-rise reinforced masonry buildings with flexible diaphragms
    Cohen, Gregory L.
    Klingner, Richard E.
    Hayes, John R., Jr.
    Sweeney, Steven C.
    MASONRY, 2008, 1496 : 109 - +
  • [45] Inelastic torsional seismic response of nominally symmetric reinforced concrete frame structures: Shaking table tests
    Benavent-Climent, A.
    Morillas, L.
    Escolano-Margarit, D.
    ENGINEERING STRUCTURES, 2014, 80 : 109 - 117
  • [46] Development of Double Frame Method to improve the seismic performance of low-rise reinforced concrete buildings
    Hur, Moo-Won
    Lee, Hyun-Ho
    Park, Tae-Won
    Ryu, Jeong-Sik
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2024,
  • [47] Innovative decoupling system for the seismic protection of masonry infill walls in reinforced concrete frames
    Marinkovic, Marko
    Butenweg, Christoph
    ENGINEERING STRUCTURES, 2019, 197
  • [48] Investigation of Seismic Performance for Low-Rise RC Buildings with Different Patterns of Infill Walls
    Saengyuan, Saharat
    Latcharote, Panon
    BUILDINGS, 2022, 12 (09)
  • [49] Shaking Table Test on Seismic Pounding Response of Reinforced Concrete Bridge
    Yan, Xiaoyu
    Wang, Lihui
    Du, Xiuli
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 1519 - +
  • [50] Seismic collapse fragility of low-rise steel moment frames with mass irregularity based on shaking table test
    Bai, Yongtao
    Li, Yinsheng
    Tang, Zhenyun
    Bittner, Marius
    Broggi, Matteo
    Beer, Michael
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (06) : 2457 - 2482