The portion of the cornea that transmits light for vision is clinically important in several contexts, including corneal ablation in refractive surgery. In contrast to geometric optics, Gaussian optics allows one to obtain simple, explicit formulas for the geometry of the effective corneal refractive zone for distant object points that are on or off the line of sight. In this article, Gaussian optics was used to derive the formula for the diameter of the zone and, when the zone is annular, the inner and outer diameter, as a function of corneal power, anterior chamber depth, pupil diameter, and angular position of the object point.
引用
收藏
页码:2030 / 2035
页数:6
相关论文
共 50 条
  • [21] Geometrical-optics approximation of on-axis Gaussian beam scattering by a gradient refractive index sphere
    School of Sciences, Xidian University, Xi'an, Shaanxi 710071, China
    Guangxue Xuebao, 2009, 6 (1684-1690): : 1684 - 1690
  • [22] Spherical equivalent refractive error of the pseudophakic eye with and without prior LASIK predicted using Gaussian optics
    Manns, Fabrice
    Chang, Yu-Cherng
    Cabot, Florence
    Ruggeri, Marco
    Yoo, Sonia H.
    Parel, Jean-Marie A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [23] The effect of back optic zone diameter on relative corneal refractive power distribution and corneal higher-order aberrations in orthokeratology
    Li, Na
    Lin, Weiping
    Zhang, Kailang
    Li, Bingqin
    Su, Qiang
    Du, Bei
    Wei, Ruihua
    CONTACT LENS & ANTERIOR EYE, 2023, 46 (01):
  • [24] Metalens in harmony with refractive optics
    Xueyi Zhu
    Shuming Wang
    Xuejun Yan
    Minghui Lu
    ScienceBulletin, 2019, 64 (12) : 797 - 798
  • [25] THE REFRACTIVE INDEX IN ELECTRON OPTICS
    EHRENBERG, W
    SIDAY, RE
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1951, 64 (384): : 1088 - 1089
  • [26] Metalens in harmony with refractive optics
    Zhu, Xueyi
    Wang, Shuming
    Yan, Xuejun
    Lu, Minghui
    SCIENCE BULLETIN, 2019, 64 (12) : 797 - 798
  • [27] Corneal Epithelium Thickness and Refractive Changes After Myopic Laser Corneal Refractive Surgery
    Canto-Cerdan, Mario
    El Bahrawy, Mohamed
    Alio, Jorge L.
    Casanova, Laura
    Garcia, Maria J.
    Al-Amri, Saad Abdulrahman J.
    Cavas, Francisco
    Alio del Barrio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (09) : 602 - +
  • [28] Customized Aspheric Treatment Zone Ablation to Treat Irregular Corneas After Corneal Refractive Surgery
    El Danasoury, Alaa M.
    Bains, Harkaran S.
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) : S917 - S921
  • [29] The refractive index in electron optics
    Opatowski, I
    PHYSICAL REVIEW, 1944, 65 (1/2): : 54 - 55
  • [30] Effect of Asymmetric Corneal Curvature on Optical Zone Decentration and Refractive Outcomes in SMILE for Myopic Astigmatism
    Fu, Xinyi
    Zhao, Xiaoyan
    Gao, Guohong
    Yu, Zhilong
    Wang, Feng
    Li, Shuxin
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02) : e173 - e185