Kinematic analysis of mobile-bearing total knee arthroplasty using a 6-DOF knee simulator

被引:9
|
作者
Hamai, Satoshi [1 ]
Miura, Hiromasa [1 ]
Higaki, Hidehiko [2 ]
Shimoto, Takeshi [2 ]
Nakanishi, Yoshitaka [2 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Sangyo Univ, Dept Mech Engn, Fac Engn, Fukuoka, Japan
关键词
D O I
10.1007/s00776-008-1277-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to investigate the kinematics of the polyethylene insert in two designs of mobilebearing total knee arthroplasty, using a six-degrees-of-freedom knee simulator. It was consequently not clear whether the motion of the polyethylene bearing in mobile-bearing total knee arthroplasty could be demonstrated during the gait cycle or more rapid movement. A mobile-bearing knee (Zimmer) and a low contact stress rotating-platform design (Depuy) were mounted on a simulator which was regulated by the kinematic data of gait. The simulating test was conducted under a static condition as well as under dynamic conditions of 0.5 Hz and 1.0 Hz. We recorded the motions of the implants with two charge-coupled device (CCD) cameras, and the positions of the insert were calculated. In spite of the same relative motion between the femoral component and the tibial tray, the polyethylene insert showed unique relative motion according to the given condition. The motion of the insert during the dynamic conditions was considerably decreased in comparison to the static condition in both mobile-bearing designs. In addition, the insert showed a smaller amplitude and frequency of rotations under increasing speed in the low contact stress rotating-platform design. The low contact stress rotating-platform design showed a larger amplitude and frequency of rotations than the mobilebearing knee. Despite the mobility of the insert in the mobilebearing total knee arthroplasty, the motion of the insert was decreased during dynamic conditions because of the disruption of full contact between the femoral component and the polyethylene insert. Differences in the rotation between the mobile-bearing knee and the low contact stress rotatingplatform design were due to the fixed axis of the internalexternal rotation in the low contact stress rotating-platform design. The theoretical advantages for the mobile-bearing design over the fixed-bearing design were not demonstrated in this study.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [21] Mobile-bearing total knee arthroplasty - Design factors in minimizing wear
    Dennis, Douglas A.
    Komistek, Richard A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 70 - 77
  • [22] Mobile-bearing total knee arthroplasty: A full traumatic rotation of 180°
    Affatato, S. (affatato@tecno.ior.it), 1600, Wichtig Publishing Srl (36):
  • [23] In Vivo Kinematics of a Cruciate Retaining Mobile-bearing Total Knee Arthroplasty
    Lee, Yeon Soo
    Park, Sang Jin
    Song, Eun Kyoo
    Kim, Jin Soo
    Kim, Yoon Hyuk
    Witvoet, Sietske Wimke
    Garling, Eric Harald
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2011, 12 (02) : 361 - 366
  • [24] Is Recovery Faster for Mobile-bearing Unicompartmental than Total Knee Arthroplasty?
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    Walter, Christopher A.
    Aziz-Jacobo, Jorge
    Cheney, Nicholas A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (06) : 1450 - 1457
  • [25] Frontal plane kinematics after mobile-bearing total knee arthroplasty
    Stiehl, JB
    Komistek, RD
    Haas, B
    Dennis, DA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 56 - 61
  • [26] The clinical history of mobile-bearing patella components in total knee arthroplasty
    Jordan, LR
    Dowd, JE
    Olivo, JL
    Voorhorst, PE
    ORTHOPEDICS, 2002, 25 (02) : S247 - S250
  • [27] No differences between fixed- and mobile-bearing total knee arthroplasty
    B. L. Fransen
    D. C. van Duijvenbode
    M. J. M. Hoozemans
    B. J. Burger
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1757 - 1777
  • [28] In Vivo Kinematic Analysis of Mobile-Bearing Unicompartmental Knee Arthroplasty during High Flexion Activities
    Kono, Kenichi
    Yamazaki, Takaharu
    Tamaki, Masashi
    Inui, Hiroshi
    Tanaka, Sakae
    Tomita, Tetsuya
    JOURNAL OF KNEE SURGERY, 2024, 37 (09) : 649 - 655
  • [29] Mobile-bearing total knee arthroplasty: A full traumatic rotation of 180°
    Sudenese, Alessandra
    Castiello, Emanuele
    Affatato, Saverio
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2013, 36 (06): : 421 - 425
  • [30] In vivo kinematics of a cruciate retaining mobile-bearing total knee arthroplasty
    Yeon Soo Lee
    Sang Jin Park
    Eun Kyoo Song
    Jin Soo Kim
    Yoon Hyuk Kim
    Sietske Wimke Witvoet
    Eric Harald Garling
    International Journal of Precision Engineering and Manufacturing, 2011, 12 : 361 - 366