Kinematic analysis of mobile-bearing total knee arthroplasty using a 6-DOF knee simulator

被引:9
|
作者
Hamai, Satoshi [1 ]
Miura, Hiromasa [1 ]
Higaki, Hidehiko [2 ]
Shimoto, Takeshi [2 ]
Nakanishi, Yoshitaka [2 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Sangyo Univ, Dept Mech Engn, Fac Engn, Fukuoka, Japan
关键词
D O I
10.1007/s00776-008-1277-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to investigate the kinematics of the polyethylene insert in two designs of mobilebearing total knee arthroplasty, using a six-degrees-of-freedom knee simulator. It was consequently not clear whether the motion of the polyethylene bearing in mobile-bearing total knee arthroplasty could be demonstrated during the gait cycle or more rapid movement. A mobile-bearing knee (Zimmer) and a low contact stress rotating-platform design (Depuy) were mounted on a simulator which was regulated by the kinematic data of gait. The simulating test was conducted under a static condition as well as under dynamic conditions of 0.5 Hz and 1.0 Hz. We recorded the motions of the implants with two charge-coupled device (CCD) cameras, and the positions of the insert were calculated. In spite of the same relative motion between the femoral component and the tibial tray, the polyethylene insert showed unique relative motion according to the given condition. The motion of the insert during the dynamic conditions was considerably decreased in comparison to the static condition in both mobile-bearing designs. In addition, the insert showed a smaller amplitude and frequency of rotations under increasing speed in the low contact stress rotating-platform design. The low contact stress rotating-platform design showed a larger amplitude and frequency of rotations than the mobilebearing knee. Despite the mobility of the insert in the mobilebearing total knee arthroplasty, the motion of the insert was decreased during dynamic conditions because of the disruption of full contact between the femoral component and the polyethylene insert. Differences in the rotation between the mobile-bearing knee and the low contact stress rotatingplatform design were due to the fixed axis of the internalexternal rotation in the low contact stress rotating-platform design. The theoretical advantages for the mobile-bearing design over the fixed-bearing design were not demonstrated in this study.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [1] Kinematic analysis of a posterior cruciate retaining mobile-bearing total knee arthroplasty
    Oakeshott, R
    Stiehl, JB
    Komistek, RA
    Anderson, DT
    Haas, BD
    JOURNAL OF ARTHROPLASTY, 2003, 18 (08): : 1029 - 1037
  • [2] Fixed or mobile-bearing total knee arthroplasty
    Huang C.-H.
    Liau J.-J.
    Cheng C.-K.
    Journal of Orthopaedic Surgery and Research, 2 (1)
  • [3] Mobile-Bearing Total Knee Arthroplasty A Meta-Analysis
    Carothers, Joshua T.
    Kim, Raymond H.
    Dennis, Douglas A.
    Southworth, Carleton
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04): : 537 - 542
  • [4] Early instability with mobile-bearing total knee arthroplasty
    Ridgeway, S
    Moskal, JT
    JOURNAL OF ARTHROPLASTY, 2004, 19 (06): : 686 - 693
  • [5] Modular, mobile-bearing hinge total knee arthroplasty
    Jones, RE
    Barrack, RL
    Skedros, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 306 - 314
  • [6] Mobile-bearing unicompartmental knee arthroplasty
    Keblish, PA
    Briard, JL
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 87 - 94
  • [7] Fixation of total knee arthroplasty improved by mobile-bearing design
    Russo, A
    Montagna, L
    Bragonzoni, L
    Zampagni, ML
    Marcacci, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (437) : 186 - 195
  • [8] Alternate surgical approaches in mobile-bearing total knee arthroplasty
    Keblish, PA
    ORTHOPEDICS, 2002, 25 (02) : S257 - S264
  • [9] Secondary resurfacing of the patella in mobile-bearing total knee arthroplasty
    Mockford, BJ
    Beverland, DE
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 898 - 902
  • [10] The kinematics of fixed- and mobile-bearing total knee arthroplasty
    Most, E
    Li, G
    Schule, S
    Sultan, P
    Park, SE
    Zayontz, S
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) : 197 - 207