Optimal needle size for thyroid fine needle aspiration cytology

被引:21
|
作者
Tanaka, Aki [1 ]
Hirokawa, Mitsuyoshi [2 ]
Higuchi, Miyoko [1 ]
Kanematsu, Risa [1 ]
Suzuki, Ayana [1 ]
Kuma, Seiji [2 ]
Hayashi, Toshitetsu [2 ]
Kudo, Takumi [3 ]
Miyauchi, Akira [4 ]
机构
[1] Kuma Hosp, Dept Clin Lab, Kobe, Hyogo, Japan
[2] Kuma Hosp, Dept Diagnost Pathol & Cytol, Kobe, Hyogo, Japan
[3] Kuma Hosp, Dept Internal Med, Kobe, Hyogo, Japan
[4] Kuma Hosp, Dept Surg, Kobe, Hyogo, Japan
关键词
Thyroid; Aspiration cytology; Fine needle aspiration; Needle size; Pain; SAMPLE ADEQUACY; PAIN-SCALE; BIOPSY; NODULE;
D O I
10.1507/endocrj.EJ18-0422
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Concerning the needle size for thyroid fine needle aspiration cytology (FNAC), 25-27 -gauge needles are generally used in Western countries. However, in Japan, the use of larger needles (21-22-gauge needles) is common. The aim of our study was to determine the optimal needle size for thyroid FNAC. We performed ultrasound-guided FNAC for 200 thyroid nodules in 200 patients using two different-sized needles (22 and 25 gauge). For each nodule, two passes with the different-sized needles were performed. The order of needle sizes was reversed for the second group of 100 nodules. The second aspiration was more painful than the first, regardless of the needle size. An association with more severe blood contamination was more frequently observed with the use of 22 -gauge needles (32.0%) than with the use of 25-gauge needles (17.5%) and in the second aspiration (37.5%) than in the initial aspiration (12.0%). The initial aspiration samples were more cellular than the second aspiration samples. Regarding the unsatisfactory and malignancy detection rates. there was no statistical difference between the needles. In three of seven markedly calcified nodules, it was difficult to insert 25-gauge needles into the nodules. In terms of the diagnostic accuracy and pain, either needle size can be used. We recommend using 22-gauge needles for markedly calcified nodules because 25-gauge needles bend more easily in such cases. We demonstrated that the initial aspiration tended to obtain more cellular samples and to be less contaminated. Thus, the initial aspiration is more important and should be closely attended.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 50 条
  • [21] FINE NEEDLE ASPIRATION CYTOLOGY
    MELBERGER, E
    JOURNAL OF DENTAL RESEARCH, 1977, 56 : D155 - D155
  • [22] FINE NEEDLE ASPIRATION CYTOLOGY
    BARKER, EA
    JOURNAL OF MEDICAL TECHNOLOGY, 1984, 1 (12): : 896 - 901
  • [23] Fine needle aspiration cytology
    Gadepalli, C.
    Back, G.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (05) : 555 - 555
  • [24] FINE NEEDLE ASPIRATION CYTOLOGY
    MUTCH, AF
    JOURNAL OF CLINICAL PATHOLOGY, 1985, 38 (06) : 716 - 716
  • [25] Fine Needle Aspiration Cytology
    Geissler, Katharina
    Volk, Gerd Fabian
    Guntinas-Lichius, Orlando
    LARYNGO-RHINO-OTOLOGIE, 2015, 94 (09) : 576 - 577
  • [26] FINE NEEDLE ASPIRATION CYTOLOGY
    MATHESON, NA
    BRITISH JOURNAL OF SURGERY, 1989, 76 (03) : 316 - 316
  • [27] Fine needle aspiration cytology
    Ansari, NA
    Derias, NW
    JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (07) : 541 - 543
  • [28] Comparison of fine-needle aspiration with fine-needle capillary cytology in thyroid nodules
    Hatami, H.
    Samsami, M.
    Movahedinia, S.
    Salehi, B.
    Movahedinia, M.
    Ardeshir, M.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2023, 105 (02) : 162 - 165
  • [29] Thyroid fine-needle aspiration cytology: Is there a place to virtual cytology?
    Gerhard, Rene
    Teixeira, Sofia
    da Rocha, Adriana Gaspar
    Schmitt, Fernando
    DIAGNOSTIC CYTOPATHOLOGY, 2013, 41 (09) : 793 - 798
  • [30] Diagnostic Superiority of Fine Needle Aspiration Cytology (FNAC) Technique and Fine Needle Non-Aspiration Cytology (FNNAC) in Thyroid Lesions
    Akhtar, Zahid Mahmood
    Hussain, Muhammad Saqib
    Ahmad, Saeed
    Saeed, Hassan
    Saeed, Filza
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (02): : 641 - 642