High resolution X-ray and infrared detectors using magnetic penetration depth thermometers.

被引:0
|
作者
Yeager, CJ [1 ]
Finkbeiner, F
Shirron, PJ
DiPirro, MJ
机构
[1] Raytheon STX, Lanham, MD 20706 USA
[2] Univ Maryland, College Pk, MD 20742 USA
[3] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
关键词
D O I
10.1109/77.783743
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We Pre developing a high-resolution a-ray detector using II magnetic penetration depth thermometer (PDT). a PDT uses the strong temperature dependence of the magnetic penetration depth of a superconducting film. PDTs were originally developed for use Pt liquid helium temperatures and achieved resolutions on the order of 2 nK The low intrinsic heat capacity and high sensitivity make it potentially useful for x-ray microcalorimetry. Using a superconducting bilayer film of aluminum and silver, a PDT can be developed to work Pt 100 mK or lower. a detector with a 1 mm pixel would be background limited and have on intrinsic resolution better than 2 eV out of 6 keV. Higher resolutions could be achieved for lower energy sources, making this technique useful as an infrared bolometer. Results of the current work will be presented along with analysis of design issues.
引用
收藏
页码:3334 / 3337
页数:4
相关论文
共 50 条
  • [41] IMPROVED ENERGY RESOLUTION WITH X-RAY GAS DETECTORS
    POLICARPO, AJ
    ALVES, MAF
    CARVALHO, MJ
    DAROCHA, MAG
    NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (03): : 487 - +
  • [42] SPECTRAL RESOLUTION OF CRYSTALS AND DETECTORS IN THE X-RAY REGION
    KUCZUMOW, A
    HELSEN, JA
    X-RAY SPECTROMETRY, 1989, 18 (02) : 63 - 66
  • [43] The dependence of X-ray elastic constants with respect to the penetration depth
    Mareau, Charles
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2023, 56 : 1446 - 1455
  • [44] High-resolution X-ray spectrometry of solids using the microcalorimeter X-ray detector
    Jach, Terrence
    SURFACE AND INTERFACE ANALYSIS, 2010, 42 (10-11) : 1646 - 1649
  • [45] Application of x-ray phase plate to grazing incidence x-ray topography for the control of penetration depth
    Hirano, Keiichi
    Takahashi, Yumiko
    Nagamachi, Shinji
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 537 - 540
  • [46] High efficiency silicon X-ray detectors
    Tull, CR
    Iwanczyk, JS
    Patt, BE
    Barkan, S
    Feng, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1803 - 1807
  • [47] High temperature GaAs X-ray detectors
    Lioliou, G.
    Whitaker, M. D. C.
    Barnett, A. M.
    JOURNAL OF APPLIED PHYSICS, 2017, 122 (24)
  • [48] High efficiency silicon X-ray detectors
    Tull, CR
    Iwanczyk, JS
    Patt, BE
    Barkan, S
    Feng, L
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1341 - 1345
  • [49] High energy X-ray computed tomography using semiconductor detectors
    Chirco, P
    Casali, F
    Baldazzi, G
    Querzola, E
    Rossi, M
    Zanarini, M
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY - PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE, PTS 1 AND 2, 1997, (392): : 891 - 894
  • [50] TWO-DIMENSIONAL HIGH RESOLUTION X-RAY DETECTORS FOR IMAGING AND INTENSITY MEASUREMENTS
    Fandrich, F.
    Koehler, R.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C26 - C26