COMPARISON OF ANTIBODY-CONJUGATED MAGNETIC IMMUNOASSAY AND LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY FOR THE MEASUREMENT OF CYCLOSPORINE AND TACROLIMUS IN WHOLE BLOOD

被引:18
|
作者
Cangemi, G. [1 ]
Barco, S. [1 ]
Bonifazio, P. [1 ]
Maffia, A. [1 ]
Agazzi, A. [1 ]
Melioli, G. [1 ]
机构
[1] Ist Giannina Gaslini, Lab Cent Anal, I-16147 Genoa, Italy
关键词
therapeutic drug monitoring; antibody-conjugated magnetic immunoassay; liquid chromatography-tandem mass spectrometry; immunosuppressants; cyclosporine; tacrolimus; ASSAY; EMIT;
D O I
10.1177/039463201302600214
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The aim of this work is to compare the results of a commercially available liquid chromatography tandem mass spectrometry (LC-MS/MS) method in a clinical pathology laboratory for routine Therapeutic Drug Monitoring (TDM) of cyclosporine (CsA) and tacrolimus (Tacr) in pediatric patients with those obtained with the current antibody-conjugated magnetic immunoassay (ACMIA). Whole blood levels of CsA (n= 135) and Tacr (n=100) were sequentially analyzed by using ACMIA and LC-MS/MS on pediatric transplanted patients. The differences were analyzed by using the Passing Bablok regression analysis and the Bland and Altman test. The LC-MS/MS method showed excellent reproducibility and lower limits of quantification compared to the ACMIA. A linear relationship between ACMIA and LC-MS/MS was obtained for both CsA (r= 0.9449; P<0.0001, 95% CI 0.9234 to 0.9605) and Tacr (r=0.9275; P<0.0001, 95% CI 0.8941 to 0.9506). No significant inter-method biases were observed. The analytical performances of the LC-MS/MS method make it suitable for the accurate measurement of CsA and Tacr in pediatric transplanted patients. However ACMIA results are also accurate and reliable. For this reason the choice of the method to be used in a routine clinical pathology laboratory can be made on the bases of non-analytical considerations such as costs, organization, availability of skilled personnel.
引用
收藏
页码:419 / 426
页数:8
相关论文
共 50 条
  • [21] Measurement of Serum Testosterone in Nondiabetic Young Obese Men: Comparison of Direct Immunoassay to Liquid Chromatography-Tandem Mass Spectrometry
    Martinez-Escribano, Ana
    Maroto-Garcia, Julia
    Ruiz-Galdon, Maximiliano
    Barrios-Rodriguez, Rocio
    Alvarez-Millan, Juan J.
    Cabezas-Sanchez, Pablo
    Plaza-Andrades, Isaac
    Molina-Vega, Maria
    Tinahones, Francisco J.
    Queipo-Ortuno, Maria Isabel
    Fernandez-Garcia, Jose Carlos
    BIOMOLECULES, 2020, 10 (12) : 1 - 12
  • [22] Evaluation of a Methotrexate Chemiluminescent Microparticle Immunoassay Comparison to Fluorescence Polarization Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry
    Bouquie, Regis
    Gregoire, Matthieu
    Hernando, Helene
    Azoulay, Claudine
    Dailly, Eric
    Monteil-Ganiere, Catherine
    Pineau, Alain
    Deslandes, Guillaume
    Jolliet, Pascale
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2016, 146 (01) : 119 - 124
  • [23] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [24] Measurement of cystine in urine by liquid chromatography-tandem mass spectrometry
    Wear, JE
    Keevil, BG
    CLINICAL CHEMISTRY, 2005, 51 (04) : 787 - 789
  • [25] Simultaneous quantification of cyclosporine, tacrolimus, sirolimus and everolimus in whole blood by liquid chromatography - electrospray mass spectrometry
    Ansermot, Nicolas
    Fathi, Marc
    Veuthey, Jean-Luc
    Desmeules, Jules
    Rudaz, Serge
    Hochstrasser, Denis
    CLINICAL BIOCHEMISTRY, 2008, 41 (09) : 728 - 735
  • [26] Comparison between a liquid chromatography-tandem mass spectrometry assay and a fluorescent polarization immunoassay to measure whole blood everolimus concentration in heart and renal transplantations
    Dailly, Eric
    Deslandes, G.
    Hourmant, M.
    Petit, T.
    Renaud, C.
    Treilhaud, M.
    Jolliet, P.
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2008, 22 (04) : 282 - 285
  • [27] Comparison of conventional liquid chromatography-tandem mass spectrometry versus microflow liquid chromatography-tandem mass spectrometry within the framework of full method validation for simultaneous quantification of 40 antidepressants and neuroleptics in whole blood
    Steuer, Andrea E.
    Poetzsch, Michael
    Koenig, Magdalena
    Tingelhoff, Eva
    Staeheli, Sandra N.
    Roemmelt, Andreas T.
    Kraemer, Thomas
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1381 : 87 - 100
  • [28] Measurement of leukotrienes in human plasma and urine by enzyme immunoassay and liquid chromatography-tandem mass spectrometry.
    Cheryk, L. A.
    Morin, A. E.
    O'Donnell, A. A.
    Ashby, C. R.
    Wendt, P. C.
    Verma, A. K.
    Oliver, L. K.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A42 - A42
  • [29] Determination of 17α-hydroxyprogesterone in serum by liquid chromatography-tandem mass spectrometry and immunoassay
    Turpeinen, U
    Itkonen, O
    Ahola, L
    Stenman, UH
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2005, 65 (01): : 3 - 12
  • [30] Rapid determination of nine barbiturates in human whole blood by liquid chromatography-tandem mass spectrometry
    Zhang, Xinyu
    Lin, Zebin
    Li, Jiaolun
    Huang, Zhibin
    Rao, Yulan
    Liang, Hao
    Yan, Jie
    Zheng, Feng
    DRUG TESTING AND ANALYSIS, 2017, 9 (04) : 588 - 595