The experience gained during four years of operation of the CMD-2 drift chamber is reported. Offline calibration of the DC parameters using a sample of Bhabha scattering events is described. Fine corrections to the Lorentz angle allow one to improve the momentum resolution. The systematic error in the determination of the polar angle was substantially decreased when information from the Z-chamber cathode was used for calibration.
引用
收藏
页码:432 / 433
页数:2
相关论文
共 50 条
  • [31] Superconducting rectifier fluxpump for magnet system of the CMD-2 detector
    Barkov, LM
    Bashtovoy, NS
    Karpov, SV
    Okhapkin, VS
    Ruban, AA
    Smakhtin, VP
    Snopkov, IG
    Zhuravkov, IV
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (03) : 4585 - 4590
  • [32] Update: A reanalysis of hadronic cross section measurements at CMD-2
    Akhmetshin, RR
    Anashkin, E
    Arbuzov, AB
    Banzarov, VS
    Baratt, A
    Barkov, LM
    Bogdan, A
    Bondar, AE
    Bondarev, D
    Eidelman, SI
    Epifanov, DA
    Fedotovich, G
    Gabyshev, NI
    Gorbachev, DA
    Grebenuk, AA
    Grigoriev, DN
    Hughes, VW
    Ignatov, FV
    Kazanin, VF
    Khazin, BI
    Krokovny, PP
    Kuraev, EA
    Kurdadze, LM
    Kuzmin, AS
    Lischenko, YE
    Logashenko, IB
    Lukin, PA
    Mikhailov, KY
    Miller, JP
    Milstein, AL
    Nikulin, MA
    Popov, AS
    Roberts, BL
    Root, NI
    Ryskulov, NM
    Shatunov, YM
    Shwartz, BA
    Sibidanov, AL
    Sidorov, VA
    Skrinsky, AN
    Smakhtin, VP
    Solodov, EP
    Stepanov, PY
    Thompson, JA
    Zaitsev, AS
    PHYSICS LETTERS B, 2004, 578 (3-4) : 285 - 289
  • [33] Precise measurement of hadronic cross sections with CMD-2 detector
    Sibidanov, AL
    HADRON SPECTROSCOPY, 2006, 814 : 478 - 485
  • [34] The BGO endcap calorimeter with phototriode readout for the CMD-2 detector
    Akhmetshin, RR
    Grigoriev, DN
    Kazanin, VF
    Ruban, AA
    Smakhtin, VP
    Yudin, YV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2): : 249 - 254
  • [35] PERFORMANCE OF THE BGO ENDCAP CALORIMETER WITH PHOTOTRIODE READOUT FOR THE CMD-2 DETECTOR
    GRIGORIEV, DN
    AKHMETSHIN, RR
    BESCHASTNOV, PM
    FEDORENKO, VE
    PYATA, EE
    SMAKHTIN, VP
    YUDIN, YV
    SHLEGEL, VN
    VASILIEV, YV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 505 - 509
  • [36] Study of the process e+e-→π+π-π+π-π0 with the CMD-2 detector
    Akhmetshin, RR
    Anashkin, EV
    Aulchenko, VM
    Banzarov, VS
    Barkov, LM
    Baru, SE
    Bondar, AE
    Bragin, AV
    Chernyak, DV
    Eidelman, SI
    Bashtovoy, NS
    Fedotovich, GV
    Gabyshev, NI
    Grebeniuk, AA
    Grigoriev, DN
    Ignatov, FV
    Ivanov, PM
    Karpov, SV
    Kazanin, VF
    Khazin, BI
    Koop, IA
    Krokovny, PP
    Kurdadze, LM
    Kuzmin, AS
    Logashenko, IB
    Lukin, PA
    Lysenko, AP
    Mikhailov, KY
    Milstein, AI
    Nesterenko, IN
    Okhapkin, VS
    Perevedentsev, EA
    Polunin, AA
    Popov, AS
    Purlatz, TA
    Root, NI
    Ruban, AA
    Ryskulov, NM
    Shamov, AG
    Shatunov, YM
    Shwartz, BA
    Sibidanov, AL
    Sidorov, VA
    Skrinsky, AN
    Smakhtin, VP
    Snopkov, IG
    Solodov, EP
    Stepanov, PY
    Sukhanov, AI
    Yudin, YV
    PHYSICS LETTERS B, 2000, 489 (1-2) : 125 - 130
  • [37] CALIBRATION SETUP FOR DRIFT CHAMBER GASES
    BECKER, UJ
    CHANG, YH
    DONAHUE, JF
    SARAKINOS, ME
    SASSER, GE
    SMITH, BR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (1-2): : 194 - 199
  • [38] CALIBRATION AND PERFORMANCE OF A DRIFT CHAMBER SPECTROMETER
    CHANDLEE, C
    BERG, D
    CIHANGIR, S
    COLLICK, B
    FERBEL, T
    HEPPELMANN, S
    HUSTON, J
    JENSEN, T
    JONCKHEERE, A
    JOYCE, T
    KOEHLER, P
    LOBKOWICZ, F
    MAKDISI, Y
    MARSHAK, M
    MCLAUGHLIN, M
    NELSON, C
    OHSHIMA, T
    PETERSON, E
    RUDDICK, K
    SLATTERY, P
    THOMPSON, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 215 (03): : 369 - 375
  • [39] Performance of the BGO endcap calorimeter with phototriode readout for the CMD-2 detector
    Grigoriev, D.N.
    Akhmetshin, R.R.
    Beschastnov, P.M.
    Fedorenko, V.E.
    Pyata, E.E.
    Smakhtin, V.P.
    Yudin, Yu.V.
    Shlegel, V.N.
    Vasiliev, Ya.V.
    IEEE Transactions on Nuclear Science, 1995, 42 (4 pt 1): : 505 - 509
  • [40] Observation of the conversion decay φ → π0e+e- CMD-2
    Akhmetshin, RR
    Anashkin, EV
    Arpagaus, M
    Aulchenko, VM
    Banzarov, VS
    Barkov, LM
    Bashtovoy, NS
    Bondar, AE
    Bondarev, DV
    Bragin, AV
    Chernyak, DV
    Eidelman, SI
    Fedotovitch, GV
    Gabyshev, NI
    Grebeniuk, AA
    Grigoriev, DN
    Hughes, VW
    Ignatov, FV
    Ivanov, PM
    Karpov, SV
    Kazanin, VF
    Khazin, BI
    Koop, IA
    Krokovny, PP
    Kurdadze, LM
    Kuzmin, AS
    Lechner, M
    Logashenko, IB
    Lukin, PA
    Mikhailov, KY
    Nesterenko, IN
    Okhapkin, VS
    Otboev, AV
    Perevedentsev, EA
    Popov, AS
    Purlatz, TA
    Root, NI
    Ruban, AA
    Ryskulov, NM
    Shamov, AG
    Shatunov, YM
    Shwartz, BA
    Sibidanov, AL
    Sidorov, VA
    Skrinsky, AN
    Smakhtin, VP
    Snopkov, IG
    Solodov, EP
    Stepanov, PY
    Sukhanov, AI
    PHYSICS LETTERS B, 2001, 503 (3-4) : 237 - 244