Label-free detection of glycoproteins by the lectin biosensor down to attomolar level using gold nanoparticles

被引:77
|
作者
Bertok, Tomas [1 ]
Sediva, Alena [1 ]
Katrlik, Jaroslav [1 ]
Gemeiner, Pavol [2 ]
Mikula, Milan [2 ]
Nosko, Martin [3 ]
Tkac, Jan [1 ]
机构
[1] Slovak Acad Sci, Inst Chem, Dept Glycobiotechnol, Bratislava 84538, Slovakia
[2] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Dept Graph Arts Technol & Appl Photochem, Bratislava 81237, Slovakia
[3] Slovak Acad Sci, Inst Mat & Machine Mech, Bratislava 83102, Slovakia
基金
欧洲研究理事会;
关键词
Ultrasensitive biosensor; Lectin; Electrochemical impedance spectroscopy (EIS); Self-assembled monolayer (SAM); Gold nanoparticles; Glycoproteins; Attomolar (aM) concentration; Sialic acid; SURFACE-PLASMON RESONANCE; SELF-ASSEMBLED MONOLAYERS; FREE PROTEIN-DETECTION; IMPEDANCE SPECTROSCOPY; ELECTROCHEMICAL BIOSENSORS; PEPTIDE APTAMERS; REAL-TIME; DNA; ELECTRODE; BINDING;
D O I
10.1016/j.talanta.2013.02.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present here an ultrasensitive electrochemical biosensor based on a lectin biorecognition capable to detect concentrations of glycoproteins down to attomolar (aM) level by investigation of changes in the charge transfer resistance (R-ct) using electrochemical impedance spectroscopy (EIS). On polycrystalline gold modified by an aminoalkanethiol linker layer, gold nanoparticles were attached. A Sambucus nigra agglutinin was covalently immobilised on a mixed self-assembled monolayer formed on gold nanoparticles and finally, the biosensor surface was blocked by poly(vinyl alcohol). The lectin biosensor was applied for detection of sialic acid containing glycoproteins fetuin and asialofetuin. Building of a biosensing interface was carefully characterised by a broad range of techniques such as electrochemistry, EIS, atomic force microscopy, scanning electron microscopy and surface plasmon resonance with the best performance of the biosensor achieved by application of HS-(CH2)(11)-NH2 linker and gold nanoparticles with a diameter of 20 nm. The lectin biosensor responded to an addition of fetuin (8.7% of sialic acid) with sensitivity of (338 +/- 11) Omega decade(-1) and to asialofetuin (<= 0.5% of sialic acid) with sensitivity of (109 +/- 10) Omega decade(-1) with a blank experiment with oxidised asialofetuin (without recognisable sialic acid) revealing sensitivity of detection of (79 +/- 13) Omega decade(-1). These results suggest the lectin biosensor responded to changes in the glycan amount in a quantitative way with a successful validation by a lectin microarray. Such a biosensor device has a great potential to be employed in early biomedical diagnostics of diseases such as arthritis or cancer, which are connected to aberrant glycosylation of protein biomarkers in biological fluids. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 50 条
  • [1] Graphene oxide-based electrochemical label-free detection of glycoproteins down to aM level using a lectin biosensor
    Klukova, L.
    Filip, J.
    Belicky, S.
    Vikartovska, A.
    Tkac, J.
    ANALYST, 2016, 141 (14) : 4278 - 4282
  • [2] Aptamer biosensor for label-free impedance spectroscopy detection of thrombin based on gold nanoparticles
    Li, Li-Dong
    Zhao, Hong-Tao
    Chen, Zheng-Bo
    Mu, Xiao-Jiao
    Guo, Lin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01): : 189 - 194
  • [3] A label-free fluorescence biosensor for highly sensitive detection of lectin based on carboxymethyl chitosan-quantum dots and gold nanoparticles
    Liu, Ziping
    Liu, Hua
    Wang, Lei
    Su, Xingguang
    ANALYTICA CHIMICA ACTA, 2016, 932 : 88 - 97
  • [4] Label-free electrochemical biosensor based on dual amplification of gold nanoparticles and polycaprolactones for CEA detection
    Wang, Xia
    Qin, Zhe
    Zhang, Fei
    Li, Chong
    Yuan, Xianxian
    Yang, Jing
    Yang, Huaixia
    TALANTA, 2024, 278
  • [5] Direct and Label-Free Quantification of Micro-RNA-181a at Attomolar Level in Complex Media Using a Nanophotonic Biosensor
    Huertas, Cesar S.
    Farina, David
    Lechuga, Laura M.
    ACS SENSORS, 2016, 1 (06): : 748 - 756
  • [6] Plasmon-Based Label-Free Biosensor Using Gold Nanosphere for Dengue Detection
    Mahmood, Hafiz Zeeshan
    Jilani, Asim
    Farooq, Sajid
    Javed, Yasir
    Jamil, Yasir
    Iqbal, Javed
    Ullah, Sami
    Wageh, Swelm
    CRYSTALS, 2021, 11 (11)
  • [7] Label-Free Attomolar Detection of Proteins Using Integrated Nanoelectronic and Electrokinetic Devices
    Gong, Jian-Ru
    SMALL, 2010, 6 (08) : 967 - 973
  • [8] Nanostructured mesoporous gold biosensor for microRNA detection at attomolar level
    Masud, Mostafa Kamal
    Na, Jongbeom
    Lin, Tzu-En
    Malgras, Victor
    Preet, Anant
    Ibn Sina, Abu Ali
    Wood, Kathleen
    Billah, Mutasim
    Kim, Jeonghun
    You, Jungmok
    Kani, Kenya
    Whitten, Andrew E.
    Salomon, Carlos
    Nguyen, Nam-Trung
    Shiddiky, Muhammad J. A.
    Trau, Matt
    Hossain, Md Shahriar A.
    Yamauchi, Yusuke
    BIOSENSORS & BIOELECTRONICS, 2020, 168 (168):
  • [9] A novel, label-free immunosensor for the detection of α-fetoprotein using functionalised gold nanoparticles
    Liang, Wenbin
    Yi, Weijing
    Li, Shuhui
    Yuan, Ruo
    Chen, An
    Chen, Sha
    Xiang, Guiming
    Hu, Chuanmin
    CLINICAL BIOCHEMISTRY, 2009, 42 (15) : 1524 - 1530
  • [10] Determination of cysteamine using label-free gold nanoparticles
    Apyari, Vladimir V.
    Dmitrienko, Stanislava G.
    Arkhipova, Viktoriya V.
    Atnagulov, Aydar G.
    Zolotov, Yuri A.
    ANALYTICAL METHODS, 2012, 4 (10) : 3193 - 3199