摘要
Many gas-pbase reactions result in a pressure buildup that is very fast, but slower than that for an explosion (that is, a deflagration). Sizing a relief vent by the conventional method, which assumes a steady state discharge mass flow rate that is sufficient to remove energy from the vessel at a rate equal to the maximum rate at which it is input into or released within in the vessel, can result in an unacceptably large vent size. A metbod previously proposed by DuPont, which is based on an experimental rate constant for the deflagration reaction (the "violence coefficient") and an empirical expression for the vent mass flux gives the vent size that limits the maximum transient pressure to less than the maximum allowable vessel pressure results in more realistic vent sizes. This paper compares the results of these two methods, as well as a modified metbod using a more general relation for the valve flow capacity, with the data for an ethylene decomposition reaction reported by DuPont. The modified metbod can be used for any gaseous relief with a known reaction rate constant and gas density as a function of pressure. 9 2006 American Institute of Chemical Engineers Process.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [41] Dust explosion vent sizing - Current methods and future developments
    Tamanini, F
    JOURNAL DE PHYSIQUE IV, 2002, 12 (PR7): : 31 - 44
  • [42] THE PHENOL + FORMALDEHYDE RUNAWAY REACTION - VENT SIZING FOR REACTOR PROTECTION
    GUSTIN, JL
    FILLION, J
    TREAND, G
    ELBIYAALI, K
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 1993, 6 (02) : 103 - 113
  • [43] Unified correlations for vent sizing of enclosures at atmospheric and elevated pressures
    Molkov, VV
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2001, 14 (06) : 567 - 574
  • [44] Vent sizing: Analysis of the blowdown of a hybrid non tempered system
    Vechot, Luc
    Minko, Wilfried
    Bigot, Jean-Pierre
    Kazmierczak, Marc
    Vicot, Patricia
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 191 (1-3) : 8 - 18
  • [45] An example of a test method for vent sizing - OPPSD/SPI methodology
    Poteet, CS
    Banks, ML
    PROCESS SAFETY PROGRESS, 2002, 21 (02) : 85 - 96
  • [46] Sizing Calculations for Pressure-Relief Valves
    Kim, Jung Seob
    Dunsheath, Heather Jean
    Singh, Navneet Radheshyam
    CHEMICAL ENGINEERING, 2013, 120 (02) : 35 - 39
  • [47] SIZING RELIEF VALVES FOR FIRE EMERGENCIES.
    Crozier Jr., R.A.
    Chemical Engineering (New York), 1985, 92 (22): : 49 - 54
  • [48] SIZING GAS PRESSURE-RELIEF NOZZLES
    CONSTANTINESCU, S
    CHEMICAL ENGINEERING, 1985, 92 (09) : 85 - 86
  • [49] Sizing Emergency Relief Systems for Multipurpose Plants
    Nanchen, Annik
    Stoessel, Francis
    LP2013 - 14TH SYMPOSIUM ON LOSS PREVENTION AND SAFETY PROMOTION IN THE PROCESS INDUSTRIES, VOLS I AND II, 2013, 31 : 757 - 762
  • [50] RELIEF LINE SIZING FOR GASES .1.
    DUXBURY, HA
    CHEMICAL ENGINEER-LONDON, 1979, (350): : 783 - 787