Study and Optimization of Design Parameters in Water Loop Heat Pump Systems for Office Buildings in the Iberian Peninsula

被引:2
|
作者
Javier Fernandez, Francisco [1 ]
Belen Folgueras, Maria [1 ]
Suarez, Ines [1 ]
机构
[1] Univ Oviedo, Polytech Sch Engn, C Wifredo Ricart S-N, Gijon 33204, Spain
关键词
water loop heat pump; heating ventilating and air conditioning; office building energy consumption;
D O I
10.3390/en10121958
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Water loop heat pump (WLHP) air conditioning systems use heat pumps connected to a common water circuit to fulfill the energy demands of different thermal zones in a building. In this study, the energy consumption was analyzed for the air conditioning of an office building in the typical climate of four important cities of the Iberian Peninsula. The energy consumption of one water loop heat pump system was compared with a conventional water system. Two design parameters, the range in the control temperatures and the water loop thermal storage size, were tested. Energy redistribution is an important advantage of the WLHP system, but significant savings came from high efficiency parameters in the heat pumps and minor air flow rates in the cooling tower. The low thermal level in the water loop makes this technology appropriate to combine with renewable sources. Using natural gas as the thermal energy source, a mean decrease in CO2 emissions of 8.1% was reached. Simulations showed that the installation of big thermal storage tanks generated small energy savings. Besides, the total annual consumption in buildings with high internal loads can be reduced by keeping the water loop as cool as possible.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Open-loop direct surface water cooling and surface water heat pump systems - A review
    Mitchell, Matt S.
    Spitler, Jeffrey D.
    HVAC&R RESEARCH, 2013, 19 (02): : 125 - 140
  • [32] Design and feasibility study of combined heat and power systems integrated with heat pump
    Cho, Heejin
    Sarwar, Riasat
    Mago, Pedro J.
    Luck, Rogelio
    APPLIED THERMAL ENGINEERING, 2016, 93 : 155 - 165
  • [33] Analysis and optimization of the design parameters of a district groundwater heat pump system in Turin, Italy
    Saez Blazquez, Cristina
    Verda, Vittorio
    Martin Nieto, Ignacio
    Farfan Martin, Arturo
    Gonzalez-Aguilera, Diego
    RENEWABLE ENERGY, 2020, 149 : 374 - 383
  • [34] Air source heat pump water heaters in residential buildings in Australia: Identification of key performance parameters
    Vieira, Abel S.
    Stewart, Rodney A.
    Beal, Cara D.
    ENERGY AND BUILDINGS, 2015, 91 : 148 - 162
  • [35] Financial optimization and design of hybrid ground-coupled heat pump systems
    Henault, Benjamin
    Pasquier, Philippe
    Kummert, Michael
    APPLIED THERMAL ENGINEERING, 2016, 93 : 72 - 82
  • [36] Improving ground-source heat pump efficiency: Optimizing pumping control and configuration of closed-loop heat pump systems in smaller commercial buildings
    Hart, Reid
    Price, Will
    Proceedings ACEEE Summer Study on Energy Efficiency in Buildings, 2000, 10 : 111 - 10
  • [37] Simulation study on supply temperature optimization in domestic heat pump systems
    Huchtemann, K.
    Mueller, D.
    BUILDING AND ENVIRONMENT, 2013, 59 : 327 - 335
  • [38] Performance optimization and benefit analyses of a photovoltaic loop heat pipe/solar assisted heat pump water heating system
    Li, Hong
    Sun, Yue
    RENEWABLE ENERGY, 2019, 134 : 1240 - 1247
  • [39] PACKAGED TERMINAL AIR CONDITIONERS AND CLOSED-LOOP WATER SOURCE HEAT PUMP SYSTEMS
    BENNETT, JH
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1972, 14 (06): : 42 - &
  • [40] Thermal performance and energy saving effect of water-loop heat pump systems with geothermal
    Li, XG
    ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (3-4) : 295 - 301