An ion source for radiofrequency-pulsed glow discharge time-of-flight mass spectrometry

被引:11
|
作者
Gonzalez Gago, C. [2 ]
Lobo, L. [1 ]
Pisonero, J. [2 ]
Bordel, N. [2 ]
Pereiro, R. [1 ]
Sanz-Medel, A. [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Univ Oviedo, Fac Sci, Dept Phys, Oviedo 33007, Spain
关键词
Glow discharge; Ion source; GD-MS; OPTICAL-EMISSION SPECTROMETRY; GAS-FLOW RATES; FREQUENCY; GRIMM; RESOLUTION;
D O I
10.1016/j.sab.2012.06.043
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A Grimm-type glow discharge (GD) has been designed and constructed as an ion source for pulsed radio-frequency GD spectrometry when coupled to an orthogonal time of flight mass spectrometer. Pulse shapes of argon species and analytes were studied as a function of the discharge conditions using a new in-house ion source (UNIOVI GD) and results have been compared with a previous design (PROTOTYPE GD). Different behavior and shapes of the pulse profiles have been observed for the two sources evaluated, particularly for the plasma gas ionic species detected. In the more analytically relevant region (afterglow), signals for Ar-40(+) with this new design were negligible, while maximum intensity was reached earlier in time for (41)(ArH)(+) than when using the PROTOTYPE GD. Moreover, while maximum Ar-40(+) signals measured along the pulse period were similar in both sources, (41)(ArH)(+) and (80)(Ar-2)(+) signals tend to be noticeable higher using the PROTOTYPE chamber. The UNIOVI GD design was shown to be adequate for sensitive direct analysis of solid samples, offering linear calibration graphs and good crater shapes. Limits of detection (LODs) are in the same order of magnitude for both sources, although the UNIOVI source provides slightly better LODs for those analytes with masses slightly higher than (41)(ArH)(+). (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 50 条
  • [1] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [2] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [3] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [4] Pulsed Radiofrequency Glow Discharge Time-of-Flight Mass Spectrometry for Nanostructured Materials Characterization
    Bustelo, Marta
    Fernandez, Beatriz
    Pisonero, Jorge
    Pereiro, Rosario
    Bordel, Nerea
    Vega, Victor
    Prida, Victor M.
    Sanz-Medel, Alfredo
    ANALYTICAL CHEMISTRY, 2011, 83 (01) : 329 - 337
  • [5] Investigation of the afterglow time regime in pulsed radiofrequency glow discharge time-of-flight mass spectrometry
    Gonzales Gago, C.
    Bordel, N.
    Pereiro, R.
    Sanz-Medel, A.
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (08): : 757 - 763
  • [6] Microsecond-pulsed Grimm glow discharge as a source for time-of-flight mass spectrometry
    Yang, CL
    Mohill, M
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) : 1255 - 1260
  • [7] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    Lobo, L.
    Tuccitto, N.
    Bordel, N.
    Pereiro, R.
    Pisonero, J.
    Licciardello, A.
    Tempez, A.
    Chapon, P.
    Sanz-Medel, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 2863 - 2869
  • [8] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    L. Lobo
    N. Tuccitto
    N. Bordel
    R. Pereiro
    J. Pisonero
    A. Licciardello
    A. Tempez
    P. Chapon
    A. Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2863 - 2869
  • [9] A comparison of non-pulsed radiofrequency and pulsed radiofrequency glow discharge orthogonal time-of-flight mass spectrometry for analytical purposes
    Lobo, L.
    Pisonero, J.
    Bordel, N.
    Pereiro, R.
    Tempez, A.
    Chapon, P.
    Michler, J.
    Hohl, M.
    Sanz-Medel, A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) : 1373 - 1381
  • [10] Improving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis
    Auristela Solà-Vázquez
    Beatriz Fernández
    José M. Costa-Fernández
    Rosario Pereiro
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7431 - 7443