Experimental Feasibility of Multi-Material Decomposition Imaging in Small Animal SPECT/CT system

被引:0
|
作者
Cho, Hyo-Min [1 ]
Pivovaroff, Michael [2 ]
Kim, Hee-Joung [1 ]
Lee, Chang-Lae [1 ]
Seo, Youngho [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Lawrence Livermore Natl Lab, Phys Sci Directorate, Livermore, CA USA
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
基金
新加坡国家研究基金会;
关键词
COMPUTED-TOMOGRAPHY; ENERGY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The photon counting detectors such as cadmium zinc telluride (CZT) and cadmium telluride (CdTe) have powerful advantages compared to energy integrating detectors. CZT or CdTe can detect individual gamma-ray or x-ray photon with energy discrimination. In recent years, energy-resolving and material decomposition x-ray imaging based on photon counting detectors has attracted attention from biomedical imaging researchers. We evaluated a large-area (20 cm x 20 cm) CZT detector originally built as a radionuclide detector for a small animal SPECT/CT system in combination of a microfocus x-ray source with a general goal of developing a material-decomposition imaging method. In this paper, we present experimental results from a feasibility study of multi-material decomposition imaging using the developed small animal SPECT/CT system. Our small animal SPECT/CT system has the unique capability to arrange detectors and sources flexibly. For the multi-material decomposition scan, the CZT detector and the x-ray tube were re-arranged in line. List-mode data of a phantom containing 7 different materials, with a range of densities and atomic numbers, illuminated by x-ray were acquired. The x-ray exposure conditions were: 50 kVp and 0.5 mA with 1.5-mm Al filtration. The acquired image was corrected for bad and hot pixels, gain, and offset. The attenuation profiles of each material were calculated against the x-ray energy. Measured attenuation profiles of each material were in a good agreement with the reference data of the NIST physics laboratory. In this study, we demonstrated that multi-material decomposition imaging is experimentally feasible using the photon-counting CZT detector and polychromatic x-ray. Since our system allows rotation and a large active area of CZT, we will acquire material-decomposition data tomographically in the near future.
引用
收藏
页码:3190 / 3193
页数:4
相关论文
共 50 条
  • [41] Volume Conservation Constrained Multi-Material Reconstruction for Inconsistent Spectral CT Imaging
    Yu, Xiaohuan
    Cai, Ailong
    Liang, Ningning
    Wang, Shaoyu
    Li, Lei
    Yan, Bin
    IEEE ACCESS, 2024, 12 : 58128 - 58142
  • [42] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Keiichi Magota
    Naoki Kubo
    Yuji Kuge
    Ken-ichi Nishijima
    Songji Zhao
    Nagara Tamaki
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 742 - 752
  • [43] Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging
    Magota, Keiichi
    Kubo, Naoki
    Kuge, Yuji
    Nishijima, Ken-ichi
    Zhao, Songji
    Tamaki, Nagara
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (04) : 742 - 752
  • [44] CARDIAC AND RESPIRATORY GATING FOR A SMALL ANIMAL SPECT-CT SYSTEM
    Pole, Donald J.
    Popovic, Kosta
    Williams, Mark B.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2177 - 2180
  • [45] Small animal imaging with attenuation correction using clinical SPECT/CT scanners
    Boutchko, Rostyslav
    Balakrishnan, Karthikayan
    Reutter, Bryan W.
    Sauve, Anne
    Gullberg, Grant T.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4294 - 4295
  • [46] Initial design of a Large Animal Dynamic SPECT CT imaging system
    Lyu, Zhenlei
    Ma, Tianyu
    Wang, Haipeng
    Wang, Shi
    Wu, Zhaoxia
    Liu, Yaqiang
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [47] Multi-material design in additive manufacturing—feasibility validation
    M. Leicher
    S. Kamper
    K. Treutler
    V. Wesling
    Welding in the World, 2020, 64 : 1341 - 1347
  • [48] A compact CT/SPECT system for small-object imaging
    Zingerman, Y.
    Golan, H.
    Gersten, A.
    Moalem, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 584 (01): : 135 - 148
  • [49] Design of rotating multi-pinhole SPECT system for high resolution small animal imaging.
    Ivanovic, M
    Weber, DA
    Loncaric, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 174P - 174P
  • [50] Noise correlation and its impact on the performance of multi-material decomposition-based spectral imaging in photon-counting CT
    Tang, Xiangyang
    Ren, Yan
    Xie, Huiqiao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):