Experimental Feasibility of Multi-Material Decomposition Imaging in Small Animal SPECT/CT system

被引:0
|
作者
Cho, Hyo-Min [1 ]
Pivovaroff, Michael [2 ]
Kim, Hee-Joung [1 ]
Lee, Chang-Lae [1 ]
Seo, Youngho [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Lawrence Livermore Natl Lab, Phys Sci Directorate, Livermore, CA USA
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
基金
新加坡国家研究基金会;
关键词
COMPUTED-TOMOGRAPHY; ENERGY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The photon counting detectors such as cadmium zinc telluride (CZT) and cadmium telluride (CdTe) have powerful advantages compared to energy integrating detectors. CZT or CdTe can detect individual gamma-ray or x-ray photon with energy discrimination. In recent years, energy-resolving and material decomposition x-ray imaging based on photon counting detectors has attracted attention from biomedical imaging researchers. We evaluated a large-area (20 cm x 20 cm) CZT detector originally built as a radionuclide detector for a small animal SPECT/CT system in combination of a microfocus x-ray source with a general goal of developing a material-decomposition imaging method. In this paper, we present experimental results from a feasibility study of multi-material decomposition imaging using the developed small animal SPECT/CT system. Our small animal SPECT/CT system has the unique capability to arrange detectors and sources flexibly. For the multi-material decomposition scan, the CZT detector and the x-ray tube were re-arranged in line. List-mode data of a phantom containing 7 different materials, with a range of densities and atomic numbers, illuminated by x-ray were acquired. The x-ray exposure conditions were: 50 kVp and 0.5 mA with 1.5-mm Al filtration. The acquired image was corrected for bad and hot pixels, gain, and offset. The attenuation profiles of each material were calculated against the x-ray energy. Measured attenuation profiles of each material were in a good agreement with the reference data of the NIST physics laboratory. In this study, we demonstrated that multi-material decomposition imaging is experimentally feasible using the photon-counting CZT detector and polychromatic x-ray. Since our system allows rotation and a large active area of CZT, we will acquire material-decomposition data tomographically in the near future.
引用
收藏
页码:3190 / 3193
页数:4
相关论文
共 50 条
  • [1] SPECT-CT system for small animal imaging
    Weisenberger, AG
    Wojcik, R
    Bradley, EL
    Brewer, P
    Majewski, S
    Qian, J
    Ranck, A
    Saha, MS
    Smith, K
    Smith, MF
    Welsh, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (01) : 74 - 79
  • [2] SPECT-CT system for small animal imaging
    Weisenberger, AG
    Wojcik, R
    Bradley, EL
    Brewer, P
    Majewski, S
    Qian, J
    Ranck, A
    Saha, MS
    Smith, K
    Smith, MF
    Welsh, RE
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1840 - 1844
  • [3] A compact SPECT/CT system for small animal imaging
    Hong, Key Jo
    Choi, Yong
    Lee, Sang Chul
    Lee, Soo Yeol
    Song, Tae Yong
    Min, Byung Jun
    Jung, Jin Ho
    Choe, Yearn Seong
    Lee, Kyung-Han
    Kim, Byung-Tae
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2601 - 2604
  • [4] Multi-Material Decomposition of Spectral CT Images
    Mendonca, Paulo R. S.
    Bhotika, Rahul
    Maddah, Mahnaz
    Thomsen, Brian
    Dutta, Sandeep
    Licato, Paul E.
    Joshi, Mukta C.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [5] Integrated CT-SPECT system for small animal imaging
    Williams, MB
    Zhang, GM
    More, MJ
    Goode, AR
    Majewski, S
    Wojcik, R
    Kross, B
    Popov, V
    Weisenberger, AG
    Stanton, M
    Phillips, W
    Stewart, A
    McCauley, T
    Wu, T
    DiBella, EVR
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 265 - 274
  • [6] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 63 - 67
  • [7] ALBIRA: A small animal PET/SPECT/CT imaging system
    Sanchez, F.
    Orero, A.
    Soriano, A.
    Correcher, C.
    Conde, P.
    Gonzalez, A.
    Hernandez, L.
    Moliner, L.
    Rodriguez-Alvarez, M. J.
    Vidal, L. F.
    Benlloch, J. M.
    Chapman, S. E.
    Leevy, W. M.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [8] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 797 - 801
  • [9] Feasibility of preclinical 125I-EISB SPECT imaging on a small animal SPECT/CT
    Tokunaga, Y.
    Kashiwa, K.
    Kojima, A.
    Tomiyoshi, K.
    Tomiguchi, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S747 - S748
  • [10] Development of combined CT-SPECT system for small animal imaging with A-SPECT
    Iwata, K
    Macdonald, LR
    Li, J
    Hwang, AB
    Patt, BE
    Hasegawa, BH
    RADIOLOGY, 2002, 225 : 409 - 409