Improved isobaric tandem mass tag quantification by ion mobility mass spectrometry

被引:31
|
作者
Sturm, Robert M. [1 ]
Lietz, Christopher B. [1 ]
Li, Lingjun [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Chem, Madison, WI 53706 USA
[2] Univ Wisconsin, Sch Pharm, Madison, WI 53705 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
COMPLEX PEPTIDE MIXTURES; OF-FLIGHT TECHNIQUES; QUANTITATIVE PROTEOMICS; SACCHAROMYCES-CEREVISIAE; ITRAQ QUANTIFICATION; PROTEIN QUANTITATION; RATIO COMPRESSION; RESOLUTION; REAGENTS; SEPARATIONS;
D O I
10.1002/rcm.6875
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE Isobaric tandem mass tags are an attractive alternative to mass difference tags and label-free approaches for quantitative proteomics due to the high degree of multiplexing that can be performed with their implementation. A drawback of tandem mass tags are that the co-isolation and co-fragmentation of labeled peptide precursors can result in chimeric tandem mass (MS/MS) spectra that can underestimate the fold-change expression of each peptide. Ion mobility (IM) separations coupled to quadrupole time-of-flight (Q-TOF) instruments have the potential to mitigate MS/MS spectra chimeracy since IM-MS has the ability to separate ions based on charge, m/z, and collision cross section (CCS). METHODS Two complex protein mixtures, labeled with DiLeu isobaric tandem mass tags in opposite ratios, were mixed together and analyzed by data-dependent LC/IM-MS/MS. The accuracy of reporters from interfering pairs was compared with and without IM separation. RESULTS IM separation was able to mitigate isobaric interference from differentially charged interfering ion pairs, as well as pairs of the same charge. Of the eight example precursors shown, only one had reporters that remained compressed below the significance threshold after IM separation. CONCLUSIONS The results of this investigation demonstrate proof-of-principle that IM separation of tagged precursors prior to MS/MS fragmentation can help mitigate quantitative inaccuracies caused by isobaric interference. Future improvements of the method would include software for automated correction and use of higher resolution IM instrumentations. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:1051 / 1060
页数:10
相关论文
共 50 条
  • [31] Carbohydrate Structure Characterization by Tandem Ion Mobility Mass Spectrometry (IMMS)2
    Li, Hongli
    Bendiak, Brad
    Siems, William F.
    Gang, David R.
    Hill, Herbert H., Jr.
    ANALYTICAL CHEMISTRY, 2013, 85 (05) : 2760 - 2769
  • [32] Ion mobility and tandem mass spectrometry of phosphatidylglycerol and bis(monoacylglycerol) phosphate (BMP)
    Hankin, Joseph A.
    Murphy, Robert C.
    Barkley, Robert M.
    Gijon, Miguel A.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 378 : 255 - 263
  • [33] Human Cerebellum Gangliosides: A Comprehensive Analysis by Ion Mobility Tandem Mass Spectrometry
    Biricioiu, Maria Roxana
    Sarbu, Mirela
    Ica, Raluca
    Vukelic, Zeljka
    Clemmer, David E.
    Zamfir, Alina D.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2024, 35 (04) : 683 - 695
  • [34] ITMSQ: A software tool for N- and C-terminal fragment ion pairs based isobaric tandem mass spectrometry quantification
    Xie, Li-Qi
    Zhang, Lei
    Nie, Ai-Ying
    Yan, Guo-Quan
    Yao, Jun
    Zhang, Yang
    Yang, Peng-Yuan
    Lu, Hao-Jie
    PROTEOMICS, 2015, 15 (22) : 3755 - 3764
  • [35] Comparison of flow injection analysis electrospray mass spectrometry and tandem mass spectrometry and electrospray high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry for the determination of underivatized amino acids
    McCooeye, Margaret
    Mester, Zoltan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (11) : 1801 - 1808
  • [36] Ion mobility-mass spectrometry
    Kanu, Abu B.
    Dwivedi, Prabha
    Tam, Maggie
    Matz, Laura
    Hill, Herbert H., Jr.
    JOURNAL OF MASS SPECTROMETRY, 2008, 43 (01): : 1 - 22
  • [37] Mass interferences in quantification of cyclosporine using tandem mass spectrometry spectrometry without chromatography
    Streit, F
    Armstrong, VW
    Oellerich, M
    THERAPEUTIC DRUG MONITORING, 2003, 25 (04) : 506 - 506
  • [38] Study of atmospheric pressure chemical ionization of PETN by ion mobility spectrometry/tandem mass spectrometry
    A. A. Filipenko
    E. K. Malkin
    Journal of Analytical Chemistry, 2011, 66 : 1464 - 1469
  • [39] Discrimination of large maltooligosaccharides from isobaric dextran and pullulan using ion mobility mass spectrometry
    Rashid, Abdul M.
    Saalbach, Gerhard
    Bornemann, Stephen
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (02) : 191 - 199
  • [40] Study of atmospheric pressure chemical ionization of PETN by ion mobility spectrometry/tandem mass spectrometry
    Filipenko, A. A.
    Malkin, E. K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (14) : 1464 - 1469