Fault Ride-Through Capability of Induction Generator As Offshore Wind Farm

被引:0
|
作者
Dhiman, Harsh S. [1 ]
Deshpande, Anuradha S. [1 ]
机构
[1] Maharaja Sayajirao Univ Baroda, Fac Engn & Technol, Dept Elect Engn, Vadodara, India
关键词
LVRT- Low Voltage Ride-Through; FACT- Flexible AC Transmission; Squirrel Cage Induction Generator (SCIG); Wind Energy Conversion Systems (WECS);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the wind power penetration continues to increase in the modern day electrification, the stabilized operation of wind farms interconnected with grids pose an alarming situation. Typically for an asymmetric grid fault, whose probability of occurrence is more than 70%, the voltage and VAR profile of the wind farm gets disturbed thus leading to erroneous operation of wind energy conversion system. LVRT (Low Voltage RideThrough) requirements for the wind energy conversion systems typically for an offshore based grid interconnection are still under discussion. This paper presents a FACT device based LVRT capability, where the FACT device injects reactive current in the grid during asymmetric faults as well as symmetric three phase faults.
引用
收藏
页码:961 / 965
页数:5
相关论文
共 50 条
  • [41] Increase of fault ride-through capability for the grid-connected wind farms
    Ko, H. S.
    Jatskevich, J.
    Dumont, G. A.
    Moshref, A.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 718 - +
  • [42] Fault Ride-Through Capability Enhancement of Type-4 WECS in Offshore Wind Farm via Nonlinear Adaptive Control of VSC-HVDC
    Sang, Yiyan
    Yang, Bo
    Shu, Hongchun
    An, Na
    Zeng, Fang
    Yu, Tao
    PROCESSES, 2019, 7 (08)
  • [43] Improving fault ride-through capability of wind generation system using DVR
    Amutha, N.
    Kumar, B. Kalyan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 46 : 326 - 333
  • [44] Improving fault ride through capability of induction generator-based wind farm using static compensator during asymmetrical faults
    Khani, Navid Ghardash
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (11)
  • [45] Fault Ride-Through Control of the Wind Farm Integrated with VSC-HVDC
    Wang, Yi
    Su, Xiaoqing
    Han, Xiao
    2013 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2013, : 267 - 272
  • [46] A fault ride-through strategy for accurate energy optimization of offshore wind VSC-HVDC system without improved fault ride-through strategy of wind turbines
    Xiao, Fan
    Yin, Xin
    Tang, Jinrui
    He, Qingqing
    Zhou, Keliang
    Tang, Chao
    Liu, Dan
    Ji, Xiaotong
    COMPUTERS & ELECTRICAL ENGINEERING, 2024, 118
  • [47] A novel fault ride-through capability improvement scheme for the hybrid offshore wind-wave energy conversion systems
    Rasool, Safdar
    Muttaqi, Kashem M.
    Sutanto, Danny
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 217
  • [48] Fault ride through capability of doubly-FED induction generator wind power generation system
    Ma, Hongfei
    Xu, Dianguo
    Chen, Zhe
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2009, 30 (10): : 1228 - 1233
  • [49] Distributed Generator's Fault Ride-Through Capability Design with System Relay Coordination
    Chumnanvanichkul, Sompol
    Suwanasri, Cattareeya
    Wangdee, Wijarn
    2020 8TH INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2020,
  • [50] Fault Ride-Through Capability Enhancement For Grid-Connected Permanent Magnet Synchronous Generator Driven by Wind Turbines
    Mahmoud, Mohamed Metwally
    Hemeida, Ashraf Mohamed
    Senjy, Tomonobu
    Ewais, Ahmed Mostafa
    2019 IEEE CONFERENCE ON POWER ELECTRONICS AND RENEWABLE ENERGY (IEEE CPERE), 2019, : 567 - 572