Fault Ride-Through Capability of Induction Generator As Offshore Wind Farm

被引:0
|
作者
Dhiman, Harsh S. [1 ]
Deshpande, Anuradha S. [1 ]
机构
[1] Maharaja Sayajirao Univ Baroda, Fac Engn & Technol, Dept Elect Engn, Vadodara, India
关键词
LVRT- Low Voltage Ride-Through; FACT- Flexible AC Transmission; Squirrel Cage Induction Generator (SCIG); Wind Energy Conversion Systems (WECS);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the wind power penetration continues to increase in the modern day electrification, the stabilized operation of wind farms interconnected with grids pose an alarming situation. Typically for an asymmetric grid fault, whose probability of occurrence is more than 70%, the voltage and VAR profile of the wind farm gets disturbed thus leading to erroneous operation of wind energy conversion system. LVRT (Low Voltage RideThrough) requirements for the wind energy conversion systems typically for an offshore based grid interconnection are still under discussion. This paper presents a FACT device based LVRT capability, where the FACT device injects reactive current in the grid during asymmetric faults as well as symmetric three phase faults.
引用
收藏
页码:961 / 965
页数:5
相关论文
共 50 条
  • [1] Doubly Fed Induction Generator Wind Farm Fault ride-through capability
    Hilal, Mohamed
    Errami, Youssef
    Benchagra, Mohamed
    Maaroufi, Mohamed
    Cherkaoui, Mohamed
    Ouassaid, Mohammed
    2012 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2012, : 1079 - 1082
  • [2] Fault Ride-Through Capability Improvement of Wind Farms Using Doubly Fed Induction Generator
    Karimi-Davijani, H.
    Sheikholeslami, A.
    Livani, H.
    Norouzi, N.
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 767 - 771
  • [3] Study of Fault Ride-Through Capability of Doubly Fed Induction Generator Based Wind Turbine
    Ntuli, Khulekani
    Sharma, Gulshan
    Kabeya, Musasa
    30TH SOUTHERN AFRICAN UNIVERSITIES POWER ENGINEERING CONFERENCE (SAUPEC 2022), 2022,
  • [4] Induction generator model in phase coordinates for fault ride-through capability studies of wind turbines
    Faiardo R, L. A.
    Iov, F.
    Medina R, J. Aurelio
    Hansen, A. D.
    Blaabjerg, F.
    2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 3527 - +
  • [5] Enhancement of fault ride-through capability of grid-connected wind farm
    Bhadane K.V.
    Ballal M.S.
    Moharil R.M.
    Kulkarni H.R.
    Prasad H.
    International Journal of Power Electronics, 2021, 13 (03) : 267 - 280
  • [6] Fault Ride-Through Capability of Cascaded Current-Source Converter-Based Offshore Wind Farm
    Popat, Miteshkumar
    Wu, Bin
    Zargari, Navid R.
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2013, 4 (02) : 314 - 323
  • [7] A Study of Voltage Ride-through Capability of an Offshore Wind Farm During Grid Fault Considering STATCOM Enhancement
    Huang, Zen-Wei
    Chang, Gary W.
    Li, Iverson
    Wang, Pin-Guei
    Nguyen, Tung Kha
    2021 IEEE INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC), 2021,
  • [8] Enhancement of fault ride-through capability for grid-connected wind farm
    Sun, Shixian
    Tian, Jie
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (08): : 137 - 141
  • [9] Fault ride-through capability of DFIG wind turbines
    Hansen, Anca D.
    Michalke, Gabriele
    RENEWABLE ENERGY, 2007, 32 (09) : 1594 - 1610
  • [10] Fault ride-through performance of wind turbine with doubly fed induction generator
    Zou, Heping
    Sun, Hui
    Zou, Jiyan
    ICIEA 2007: 2ND IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-4, PROCEEDINGS, 2007, : 1607 - 1611