The value of virtual touch tissue imaging quantification combined with color Doppler ultrasound and CA153 in diagnosing early breast cancer

被引:0
|
作者
Wang, Aizhu [1 ]
Wang, Bin [2 ]
Huang, Xuning [1 ]
Wang, Lehua [1 ]
Wu, Huangfu [3 ]
Fan, Huiwen [1 ]
机构
[1] Hainan Med Univ, Affiliated Hosp 2, Dept Ultrasound Med, 48 Baishuitang Rd, Haikou 570311, Hainan, Peoples R China
[2] Hainan Med Univ, Affiliated Hosp 2, Dept Intervent Radiol, Haikou, Hainan, Peoples R China
[3] Hainan Med Univ, Affiliated Hosp 2, Dept Breast & Thyroid Surg, Haikou, Hainan, Peoples R China
关键词
Breast cancer; virtual touch tissue imaging quantification; color Doppler ultrasound; carbohydrate antigen 153; diagnostic value; ELASTOGRAPHY; CHEMOTHERAPY; CELLS; CEA;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To explore the value of virtual touch tissue imaging quantification combined with color Doppler ultrasound and carbohydrate antigen 153 (CA153) in diagnosis of early breast cancer. Methods: Clinical data of 196 patients with breast masses were collected and analyzed proactively. Among these patients, 89 patients were confirmed with malignant breast tumor and 107 patients were confirmed with benign breast tumor according to final pathological report. The breast imaging reporting and data system (BI-RADS) grading quantitative score, transverse shear wave velocity (SWV), and CA153 level of all patients were analyzed. Results: The BI-RADS grading quantitative score, SWV, and CA153 level of the malignant tumor group were all significantly higher than those of the benign tumor group (all P<0.05). The area under the receiver operating characteristic curve (AUC) of SWV in diagnosing breast cancer was 0.855, and when SWV was 4.205 m/s, its sensitivity and specificity were 0.640 and 0.981, respectively; The AUC of BI-RADS score in diagnosing breast cancer was 0.797, and when the BI-RADS grading quantitative score was 3.5 points, its sensitivity and specificity were 0.798 and 0.636, respectively. The AUC of CA153 in diagnosing breast cancer was 0.838, and when the CA153 level was 19.99 U/mL, its sensitivity and specificity were 0.663 and 0.981, respectively. In addition, the AUC of SWV combined with BI-RADS grading quantitative score and CA153 in diagnosing breast cancer was 0.978, and its sensitivity and specificity were 0.910 and 0.953, respectively. Conclusion: Virtual touch tissue imaging quantification combined with color Doppler ultrasound and CA153 is of a high value in the diagnosis of breast cancer, so it is worthy of clinical application.
引用
收藏
页码:8102 / 8109
页数:8
相关论文
共 50 条
  • [21] Color-map virtual touch tissue imaging (CMV) combined with BI-RADS for the diagnosis of breast lesions
    Lian, Kai-Mei
    Lin, Teng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (03) : 447 - 457
  • [22] The value of color-map virtual touch tissue imaging (CMV) in the differential diagnosis of benign and malignant breast lesions
    Lian, Kai-Mei
    Lin, Teng
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 78 (01) : 49 - 56
  • [23] Application of conventional ultrasound coupled with virtual touch tissue imaging and quantification in the assessment of muscle strength
    Zhou, Weichen
    Ma, Xiaojuan
    Pan, Lin
    Wang, Yunhan
    Zhou, Chengting
    ANNALS OF PALLIATIVE MEDICINE, 2020, 9 (05) : 3402 - 3409
  • [24] The role of ultrasound elastography and virtual touch tissue imaging in the personalized prediction of lymph node metastasis of breast cancer
    Wang, Jue
    Ben, Zhifei
    Gao, Shanshan
    Lyu, Shuyi
    Wei, Xiuzhi
    GLAND SURGERY, 2021, 10 (04) : 1460 - 1469
  • [25] Value on the diagnosis of axillary lymph node metastasis in breast cancer by color Doppler ultrasound combined with computed tomography
    Zhou, Jianmin
    Zhang, Boxu
    Dong, Yan
    Yu, Leilei
    Gao, Tiantian
    Wang, Zhenna
    JOURNAL OF BUON, 2020, 25 (04): : 1784 - 1791
  • [26] Applications of Mechanical Arm in the Virtual Touch Tissue Imaging Quantification and the Differential Diagnosis of Breast Tumors
    Li, Ling
    Lv, Guorong
    Shen, Haolin
    Liao, Liping
    Zhong, Rong
    Zheng, Chunnuan
    Yang, Shuping
    ULTRASOUND QUARTERLY, 2022, 38 (01) : 25 - 30
  • [27] Diagnostic value of Doppler ultrasound parameters combined with MMP-11 in early breast cancer and benign breast diseases
    Ren, Hui
    Shen, Zhipeng
    Shen, Jirui
    Zhang, Yu
    Zhang, Yunhua
    ONCOLOGY LETTERS, 2020, 20 (02) : 1028 - 1032
  • [28] ADDED VALUE OF SUPERB MICROVASCULAR IMAGING AND VIRTUAL TOUCH IMAGING QUANTIFICATION IN ASSISTING THYROID CANCER CLASSIFICATION
    Zhu, Yi-Cheng
    Zhang, Yuan
    Shan, Jun
    Deng, Shu-Hao
    Shi, Xiu-Rong
    Jiang, Quan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (12): : 3364 - 3371
  • [29] The value of automated breast volume scanner combined with virtual touch tissue quantification in the differential diagnosis of benign and malignant breast lesions A comparative study with mammography
    Wang, Junli
    Fan, Hongjie
    Zhu, Yuting
    Shen, Chunyun
    Qiang, Banghong
    MEDICINE, 2021, 100 (16) : E25568
  • [30] Clinical value of virtual touch tissue imaging quantification in diagnosis and treatment of congenital muscular torticollis in children
    Luo, Hongxia
    Li, Tianran
    Wu, Senmin
    Zhu, Hui
    Chen, Kai
    Ma, Lie
    Lin, Miaomiao
    TRANSLATIONAL PEDIATRICS, 2020, 9 (01) : 13 - 20