Experimental study of temperature sensor for an ocean-going liquid hydrogen (LH2) carrier

被引:2
|
作者
Nakano, A. [1 ]
Shimazaki, T. [2 ]
Sekiya, M. [3 ]
Shiozawa, H. [3 ]
Aoyagi, A. [3 ]
Ohtsuka, K. [3 ]
Iwakiri, T. [3 ]
Mikami, Z. [3 ]
Sato, M. [3 ]
Kinoshita, K. [4 ]
Matsuoka, T. [4 ]
Takayama, Y. [5 ]
Yamamoto, K. [5 ]
机构
[1] Res Inst Energy Conservat, Natl Inst Adv Ind Sci & Technol AIST, Dept Energy & Environm, Thermofluid Syst Grp, 1-2-1 Namiki, Tsukuba, Ibaraki 3058564, Japan
[2] Res Inst Phys Measurement, NMIJ, Natl Inst Adv Ind Sci & Technol AIST, Frontier Thermometry Res Grp, Tsukuba Cent 3,1-1-1 Ulmezono, Tsukuba, Ibaraki 3058563, Japan
[3] Metyo Elect Co Ltd, Shimizu Ku, 485 Nanatsushinya, Shizuoka 4240066, Japan
[4] Netsushin Co Ltd, 2079-7 Kamitome, Saitama 3540045, Japan
[5] KEI Syst, Ikuno Ku, 1-5-1 Ikuno, Osaka 5440024, Japan
关键词
ENERGY;
D O I
10.1016/j.cryogenics.2018.01.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
The prototype temperature sensors for an ocean-going liquid hydrogen (LH2) carrier were manufactured by way of trial. All of the sensors adopted Platinum 1000 (PT-1000) resistance thermometer elements. Various configurations of preproduction temperature sensors were tested in AIST's LH2 test facility. In the experiments, a PT 1000 resistance thermometer, calibrated at the National Metrology Institute of Japan at AIST, was used as the standard thermometer. The temperatures measured by the preproduction sensors were compared with the temperatures measured by the standard thermometer, and the measurement accuracy of the temperature sensors in LH2 was investigated and discussed. It was confirmed that the measurement accuracies of the preproduction temperature sensors were within +/- 50 mK, which is the required measurement accuracy for a technical demonstration ocean-going LH2 carrier.
引用
收藏
页码:112 / 117
页数:6
相关论文
共 48 条
  • [21] Experimental study on a closed-cycle Joule-Thomson cryocooler working at liquid hydrogen temperature
    Shen, Yunwei
    Qiu, Changxu
    Liu, Dongli
    Tao, Xuan
    Wan, Anping
    Zhang, Zhiguo
    Gan, Zhihua
    APPLIED THERMAL ENGINEERING, 2023, 234
  • [22] Experimental study on regenerator materials of pulse tube refrigerator working at 20 K liquid hydrogen temperature
    Zhou, Qiang
    Chen, Liu-Biao
    Jin, Hai
    Zhu, Wen-Xiu
    Zhou, Yuan
    Wang, Jun-Jie
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2014, 35 (11): : 2124 - 2127
  • [23] Experimental and numerical study on tube-side flow and heat transfer characteristics of superheated vapor flow in catalyst-filled LH2 spiral wound heat exchanger
    Fan, Xin
    Li, Yuxing
    Sun, Chongzheng
    Liu, Liang
    Yang, Hongchao
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (86) : 36582 - 36592
  • [24] Numerical and experimental study on a tub e-in-tub e heat exchanger working at liquid-hydrogen temperature with a large temperature span
    Qiu, Changxu
    Chen, Shuhang
    Shen, Yunwei
    Tao, Xuan
    Gan, Zhihua
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 208
  • [25] Highly selective Hydrogen sensing by applying characteristic frequency at room temperature: Case study on TiO2-PdO hydrogen sensor
    Kanth, Supriya
    Domadiya, Darshil N.
    Betty, C. A.
    Kumar, Sanjay
    Choudhury, Sipra
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 106 : 231 - 242
  • [26] Low-Temperature Protein Dynamics of the B800 Molecules in the LH2 Light-Harvesting Complex: Spectral Hole Burning Study and Comparison with Single Photosynthetic Complex Spectroscopy
    Grozdanov, Daniel
    Herascu, Nicoleta
    Reinot, Tonu
    Jankowiak, Ryszard
    Zazubovich, Valter
    JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (10): : 3426 - 3438
  • [27] Experimental study on catalytic conversion and flow characteristics of ortho-para hydrogen in tubular packed-bed converters at liquid nitrogen temperature
    Wang, Kai
    Xu, Sheng
    Zheng, Jinming
    Zhu, Shaolong
    Fang, Song
    Xiao, Hongmei
    Li, Na
    Qiu, Limin
    CRYOGENICS, 2025, 147
  • [28] Three pulse photon echo peak shift study of the B800 band of the LH2 complex of Rps. acidophila at room temperature:: A coupled master equation and nonlinear optical response function approach
    Agarwal, R
    Yang, M
    Xu, QH
    Fleming, GR
    JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (09): : 1887 - 1894
  • [29] Experimental study of the vapour-liquid equilibria of HI-I2-H2O ternary mixtures, Part 2: Experimental results at high temperature and pressure
    Larousse, B.
    Lovera, P.
    Borgard, J. M.
    Roehrich, G.
    Mokrani, N.
    Maillault, C.
    Doizi, D.
    Dauvois, V.
    Roujou, J. L.
    Lorin, V.
    Fauvet, P.
    Carles, P.
    Hartmann, J. M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (08) : 3258 - 3266
  • [30] Experimental study on the conversion of H2 and CO from the helium carrier gas of high-temperature gas-cooled reactor
    Liao, Cuiping
    Zheng, Zhenhong
    Shi, Fuen
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 1995, 29 (05): : 441 - 448