Measurement of mini-implant stability using resonance frequency analysis

被引:39
|
作者
Nienkemper, Manuel [1 ]
Wilmes, Benedict [1 ]
Panayotidis, Agamemnon [1 ]
Pauls, Alexander [1 ]
Golubovic, Vladimir [2 ]
Schwarz, Frank [2 ]
Drescher, Dieter [1 ]
机构
[1] Univ Dusseldorf, Dept Orthodont, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Dept Oral Surg & Admittance, D-40225 Dusseldorf, Germany
关键词
Orthodontics; Skeletal anchorage; Implant stability; Resonance frequency analysis; DAMPING CAPACITY ASSESSMENT; ORTHODONTIC ANCHORAGE; IN-VITRO; BONE THICKNESS; MICRO-IMPLANTS; INTERFACE; FAILURE; TISSUE;
D O I
10.2319/043012-354.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To investigate whether resonance frequency analysis (RFA) is suitable to measure orthodontic mini-implant stability. Implant size significantly affects the level of resonance frequency. Regarding the operating mode of RFA, it has to be proven whether the resonance frequency of mini-implants in bone fits the range of frequency emitted by the Osstell ISO device. Material and Methods: For this purpose the SmartPegs in the Osstell ISO device were modified to fit with the inner screw thread of orthodontic mini-implants, and 110 mini-implants were inserted into porcine pelvic bone. RFA was performed parallel and perpendicular to the run of superficial bone fibers. A suitability test, Periotest, was also performed in the same directions. Compacta thickness was measured using cone-beam computed tomography. Correlation tests and linear regression analysis were carried out between the three methods. Results: The RFA showed a mean Implant Stability Quotient value of 36.36 +/- 2.67, and the Periotest mean value was -2.10 +/- 1.17. The differences between the two directions of measurement were statistically significant (P > .001) for RFA and the Periotest. There was a high correlation between RFA and the Periotest (r = -0.90) and between RFA and compacta thickness (r = 0.71). The comparison between the Periotest and compacta thickness showed a correlation coefficient of r = -0.64. Conclusion: The present results suggest that RFA is feasible as a measurement method for orthodontic mini-implant stability. As a consequence, it could be used for clinical evaluation of current stability and allow stability-related loading of mini-implants to reduce the failure rate. (Angle Orthod. 2013;83:230-238.)
引用
收藏
页码:230 / 238
页数:9
相关论文
共 50 条
  • [31] Evaluation of Resonance Frequency and Micromotion to Achieve Implant Stability Using Vibroacoustic Resonance Frequency Analysis: A Mathematical Model
    Khened, Vineet
    Dhok, Kanad
    Pradhan, Mahesh
    Dhatrak, Pankaj
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2023, 6 (03)
  • [32] A CBCT Assessment of Orthodontic Mini-Implant Placement
    Ashil, A. M.
    Sharma, Aseem
    Jose, Lijo K.
    Grover, Shubhi
    Kochar, Anuraj Singh
    Varghese, Shaji T.
    Sharma, Tanushree
    Ismail, Prabu Mahin Syed
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S927 - S929
  • [33] Biomechanics of incisor retraction with mini-implant anchorage
    Upadhyay, Madhur
    Yadav, Sumit
    Nanda, Ravindra
    JOURNAL OF ORTHODONTICS, 2014, 41 : S15 - S23
  • [34] Infrazygomatic mini-implant penetration into the maxillary sinus
    Valladares-Neto, Jose
    Evangelista, Karine
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 154 (04) : 462 - 463
  • [35] Mini-implant for intrusion: Is it always justified? Response
    Kim, Tae-Woo
    Kim, Hyewon
    Lee, Shin-Jae
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (03) : 298 - 300
  • [37] Mini-implant applications in orthognathic surgical treatment
    Cousley, Richard R. J.
    Turner, Mark J.
    JOURNAL OF ORTHODONTICS, 2014, 41 : S54 - S61
  • [38] Effects of washer on the stress distribution of mini-implant A finite element analysis
    Jang, Hyoung-Jun
    Kwon, Soon-Yong
    Kim, Seong-Hun
    Park, Young-Guk
    Kim, Su-Jung
    ANGLE ORTHODONTIST, 2012, 82 (01) : 137 - 144
  • [39] How Does Orthodontic Mini-Implant Thread Minidesign Influence the Stability?-Systematic Review with Meta-Analysis
    Jedlinski, Maciej
    Janiszewska-Olszowska, Joanna
    Mazur, Marta
    Grocholewicz, Katarzyna
    Suquia, Pedro Suarez
    Quintanilla, David Suarez
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (18)
  • [40] Influence of the orientation of the Osstell® transducer during measurement of dental implant stability using resonance frequency analysis: A numerical approach
    Capek, Lukas
    Simunek, Antonin
    Slezak, Radovan
    Dzan, Ladislav
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (07) : 764 - 769