The Tryton® dedicated bifurcation stent: Five-year clinical outcomes

被引:1
|
作者
Green, Peregrine G. [1 ]
Stella, Pieter R. [2 ]
Kumsars, Indulis [3 ]
Dens, Jo [4 ]
Sonck, Jeroen [5 ]
Bennett, Johan [6 ]
Bethencourt, Armando [7 ]
Ramos Lopez, Benigno [8 ]
Dudek, Dariusz [9 ]
van Geuns, Robert J. [10 ]
Ramcharitar, Steve [1 ]
机构
[1] Great Western Hosp, Wiltshire Cardiac Ctr, Marlborough Rd, Swindon SN3 6BB, Wilts, England
[2] Univ Med Ctr, Dept Intervent Cardiol, Utrecht, Netherlands
[3] Paula Stradina Klin Univ Slimnica, Riga, Latvia
[4] Ziekenhuis Oost Limburg, Limburg, Belgium
[5] Univ Ziekenhuis Brussels, Brussels, Belgium
[6] Univ Ziekenhuis Leuven, Leuven, Belgium
[7] Hosp Son Dureta Palma de Mallorca, Palma De Mallorca, Spain
[8] Clin Univ Valladolid, Valladolid, Spain
[9] Univ Hosp, Krakow, Poland
[10] Thorax Ctr Rotterdam, Rotterdam, Netherlands
关键词
PERCUTANEOUS CORONARY INTERVENTION; MYOCARDIAL-INFARCTION; ARTERY BIFURCATION; RANDOMIZED-TRIAL; LESIONS; DEFINITION; CONSENSUS; DISEASE;
D O I
10.1016/j.carrev.2018.06.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: We report the first 5 year clinical follow-up data for the Tryton (R) bifurcation stent. Methods and results: Clinical outcomes at five years were collected from 8 centres. Non-hierarchical Major Adverse Cardiovascular Events (MACE) and Major Adverse Cerebrovascular and Cardiovascular Events (MACCE) were collected. Diabetic and non-diabetic populations were compared, along with small (<= 2.5 mm) vs large (>2.5 mm) side branch size. 173 patients with a follow up rate of 98% at 5 years were analysed. Non-hierarchical MACE was low at 9.8%, consisting of cardiac death of 1.2% (n = 2) and MI of 1.7% (n = 3). Target lesion revascularization (TLR) rate was 6.9% (n = 12). Non-hierarchical MACCE was also low, with major bleeding in 2.3% (n = 4) and strokes in 1.7% (n = 3) of patients. There was only 1 case (0.6%) of stent thrombosis that was definite and occurred very late (782 days). All-cause mortality was low, with 8.7% combined cardiac and non-cardiac death (n = 15). Diabetic patients had significantly higher event rates, but there was no difference in events with lesion stratification by side branch size. Conclusions: The Tryton (R) Side-Branch Stent has a non-hierarchical MACE of 9.8% and MACCE of 13.9% at 5 years. The TLR was 6.9% with only 1 case of stent thrombosis recorded. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:316 / 323
页数:8
相关论文
共 50 条
  • [11] Five-Year Clinical Outcomes of the COBRA Polyzene F NanoCoated Coronary Stent System
    Cutlip, Donald E.
    Jauhar, Rajiv
    Meraj, Perwaiz
    Garratt, Kirk N.
    Novack, Victor
    Novack, Lena
    Maillard, Luc
    Erglis, Andrejs
    Stoler, Robert
    Barakat, Mark
    Silber, Sigmund
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 41 : 76 - 80
  • [12] Use of a Dedicated Sidebranch Device for Bifurcation Disease: A Single Centre Experience of the TRYTON Stent
    Norell, Michael
    Maher, Abdul
    Martins, Joe
    Singh, Rajpal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B80 - B80
  • [13] Does a dedicated hip fracture unit improve clinical outcomes? A five-year case series
    Walton, T. J.
    Bellringer, S. F.
    Edmondson, M.
    Stott, P.
    Rogers, B. A.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2019, 101 (03) : 215 - 219
  • [14] 2-Year Clinical Follow-up of the TRYTON IDE Randomized Trial Comparing a Dedicated Bifurcation Stent to Provisional Stenting in the Treatment of Coronary Bifurcations
    Kumsars, Indulis
    Genereux, Philippe
    Kini, Annapoorna
    Lesiak, Maciej
    Fontos, Geza
    Slagboom, Ton
    Ungi, Imre
    Metzger, D. Christopher
    Wykrzykowska, Joanna J.
    Stella, Pieter R.
    Bartorelli, Antonio L.
    Fearon, William F.
    Lefevre, Thierry
    Feldman, Robert L.
    Tarantini, Giuseppe
    Laak, Linn L.
    Cutlip, Donald
    Kaplan, Aaron
    Serruys, Patrick W.
    Leon, Martin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B161 - B161
  • [15] Five-year outcomes of bifurcation stenting: insights from the SYNTAX trial
    Spaziano, M.
    Roy, A.
    Akodad, M.
    Louvard, Y.
    Lefevre, T.
    Serruys, R.
    Chevalier, B.
    Morice, M. G.
    EUROPEAN HEART JOURNAL, 2017, 38 : 443 - 444
  • [16] Five-Year Clinical Outcomes in Aorto-Ostial Lesion Treated with Drug Eluting Stent
    Park, Kyu-Hwan
    Choi, KangUn
    Lee, Chan-Hee
    Choi, YoonJung
    Son, Jang-Won
    Kim, Ung
    Park, Jong-Seon
    Shin, Dong-Gu
    Kim, Young-Jo
    Jin, Han-Young
    Jang, Jae-Sik
    Yang, Tae-Hyun
    Kim, Dong-Soo
    Seo, Guang-Won
    Kim, Dong-Kie
    Song, Pilsang
    Kim, Doo Il
    Cho, Yun-Kyeong
    Yoon, Hyuck Jun
    Nam, Chang-Wook
    Hur, Seung-Ho
    Kim, Kwon-Bae
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (17) : S72 - S72
  • [17] Impact of Total Stent Length Per Patient and Per Lesion On Five-Year Clinical Outcomes
    Shinichi, Shirai
    Takeshi, Kimura
    Takeshi, Morimoto
    Masashi, Iwabuchi
    Hiroyoshi, Yokoi
    Masakiyo, Nobuyoshi
    Kazuaki, Musudo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B58 - B59
  • [18] Outcomes of the Tryton-dedicated bifurcation stent for the treatment of true coronary bifurcations: Individual-patient-data pooled analysis
    Konigstein, Maayan
    Srdanovic, Iva
    Gore, Ankita K.
    Rahim, Hussein M.
    Genereux, Philippe
    Ben-Yehuda, Ori
    Kumsars, Indulis
    Lesiak, Maciej
    Kini, Annapoorna
    Fontos, Geza
    Slagboom, Ton
    Ungi, Imre
    Metzger, D. Christopher
    Crowley, Aaron
    Leon, Martin B.
    Ali, Ziad A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (07) : 1255 - 1261
  • [19] Five-Year Impacts of Antithrombotic Therapy Based on 10-Year Clinical Outcomes of Cypher™ Stent Implantation
    Ken Kurihara
    Shiho Kawamoto
    Ayaka Kimura
    Akifumi Tanaka
    Kento Yabe
    Hidetsugu Nomoto
    Yuki Osaka
    Toru Miyazaki
    Asami Suzuki
    Yuichi Ono
    Kenichiro Otomo
    Tetsuo Sasano
    Cardiology and Therapy, 2022, 11 : 433 - 444
  • [20] Five-Year Impacts of Antithrombotic Therapy Based on 10-Year Clinical Outcomes of Cypher™ Stent Implantation
    Kurihara, Ken
    Kawamoto, Shiho
    Kimura, Ayaka
    Tanaka, Akifumi
    Yabe, Kento
    Nomoto, Hidetsugu
    Osaka, Yuki
    Miyazaki, Toru
    Suzuki, Asami
    Ono, Yuichi
    Otomo, Kenichiro
    Sasano, Tetsuo
    CARDIOLOGY AND THERAPY, 2022, 11 (03) : 433 - 444