Acute effects of iontophoresis on human skin in vivo: Cutaneous blood flow and transepidermal water loss measurements

被引:15
|
作者
Brand, RM
Singh, P
AspeCarranza, E
Maibach, HI
Guy, RH
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT BIOPHARMACEUT SCI,SCH PHARM,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DEPT PHARMACEUT CHEM,SCH PHARM,SAN FRANCISCO,CA 94143
[3] UNIV CALIF SAN FRANCISCO,SCH MED,DEPT DERMATOL,SAN FRANCISCO,CA 94143
关键词
iontophoresis; skin barrier function; transdermal drug delivery;
D O I
10.1016/S0939-6411(96)00001-X
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The objective of this study was to quantify the acute effects of iontophoretic current passage on human skin in vivo. Specifically, local skin blood flow (SBF) and transepidermal water loss (TEWL) have been measured at the sites of electrode application before and subsequent to iontophoresis at current levels which are generally considered to be 'reasonable'. Infrared spectra were also recorded at the same skin sites using the attenuated total reflectance technique (ATR-IR). The current levels administered were up to 0.5 mA/cm(2) for a maximum of 25 min. It was found that current application for only 5 min was sufficient to cause a significant increase in SBF. Longer periods of current flow induced greater changes in SBF, the elevated level of which persisted for longer times after the termination of iontophoresis. Typically, SBF increased more beneath the anode than beneath the cathode, although visually the degree of irritation was sometimes difficult to distinguish. All subjects were able to feel the application of current, the majority registering greater discomfort at the anode. Apart from the occlusive effect of the electrode chamber solutions, iontophoresis elicited no significant change in TEWL relative to the no-current controls, Similarly, ATR-IR detected no major changes in the spectroscopic profile of the outer stratum corneum. Only relatively minor alterations in protein conformational distribution were observed. In summary, the acute effects of iontophoresis on human skin in vivo are quite moderate. The most significant effect is the rather consistent induction of an erythematous response, the persistence of which depends upon the quantity of charge and the absolute level of current delivered. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [21] BASAL TRANSEPIDERMAL WATER-LOSS, SKIN THICKNESS, SKIN BLOOD-FLOW AND SKIN COLOR IN RELATION TO SODIUM-LAURYL-SULFATE-INDUCED IRRITATION IN NORMAL SKIN
    AGNER, T
    CONTACT DERMATITIS, 1991, 25 (02) : 108 - 114
  • [22] EFFECTS OF THE PELOID CREAM FROM THE MONTENEGRIN ADRIATIC COAST ON SKIN HUMIDITY, TRANSEPIDERMAL WATER LOSS AND ERYTHEMA INDEX, EXAMINED WITH SKIN BIOENGENEERING IN VIVO METHODS
    Potpara, Zorica
    Duborija-Kovacevic, Natasa
    FARMACIA, 2012, 60 (04) : 524 - 534
  • [23] STANDARDIZED TRAUMA (TAPE STRIPPING) IN HUMAN VULVAR AND FOREARM SKIN - EFFECTS ON TRANSEPIDERMAL WATER-LOSS, CAPACITANCE AND PH
    WILHELM, D
    ELSNER, P
    MAIBACH, HI
    ACTA DERMATO-VENEREOLOGICA, 1991, 71 (02) : 123 - 126
  • [24] COMPARISON OF PHYSICAL MEASUREMENTS CONCERNING CUTANEOUS BLOOD FLOW AFTER LOCAL APPLICATION OF BENZYLNICOTINATE - THERMAL MEASUREMENTS OF COURSE OF ERYTHEMA - WATER VAPOR LOSS AND SKIN RESISTANCE
    EMDEN, J
    SCHAEFER, H
    STUTTGEN, G
    ARCHIV FUR DERMATOLOGISCHE FORSCHUNG, 1971, 241 (04): : 353 - &
  • [25] Effect of tap-water iontophoresis on sweat gland recruitment, skin temperature and skin blood flow
    Kolkhorst, FW
    DiPasquale, DM
    Buono, MJ
    JOURNAL OF DERMATOLOGICAL SCIENCE, 2002, 28 (02) : 97 - 101
  • [26] Transepidermal water loss reflects permeability barrier status:: validation in human and rodent in vivo and ex vivo models
    Fluhr, Joachim W.
    Feingold, Kenneth R.
    Elias, Peter M.
    EXPERIMENTAL DERMATOLOGY, 2006, 15 (07) : 483 - 492
  • [27] Comparison of Transepidermal Water Loss and Laser Scanning Microscopy Measurements to Assess Their Value in the Characterization of Cutaneous Barrier Defects
    Czaika, V.
    Alborova, A.
    Richter, H.
    Sterry, W.
    Vergou, T.
    Antoniou, C.
    Lademann, J.
    Koch, S.
    SKIN PHARMACOLOGY AND PHYSIOLOGY, 2012, 25 (01) : 39 - 46
  • [28] Thin film sensor for transepidermal water loss measurement -: Calibration method and application to human skin
    Valentin, B
    Mündlein, M
    Chabicovsky, R
    Nicolics, J
    2005 28TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, 2005, : 64 - 68
  • [29] Effect of heat-killed Lactobacillus brevis SBC8803 on cutaneous arterial sympathetic nerve activity, cutaneous blood flow and transepidermal water loss in rats
    Horii, Y.
    Kaneda, H.
    Fujisaki, Y.
    Fuyuki, R.
    Nakakita, Y.
    Shigyo, T.
    Nagai, K.
    JOURNAL OF APPLIED MICROBIOLOGY, 2014, 116 (05) : 1274 - 1281
  • [30] Effects of microneedle length, density, insertion time and multiple applications on human skin barrier function: Assessments by transepidermal water loss
    Gomaa, Yasmine A.
    Morrow, Desmond I. J.
    Garland, Martin J.
    Donnelly, Ryan F.
    El-Khordagui, Labiba K.
    Meidan, Victor M.
    TOXICOLOGY IN VITRO, 2010, 24 (07) : 1971 - 1978