Incremental Value of Perfusion over Wall-Motion Abnormalities with the Use of Dobutamine-Atropine Stress Myocardial Contrast Echocardiography and Magnetic Resonance Imaging for Detecting Coronary Artery Disease

被引:14
|
作者
dos Reis Saraiva Falcao, Sandra Nivea [1 ]
Rochitte, Carlos Eduardo [1 ]
Mathias Junior, Wilson [1 ]
Quaglia, Luiz [1 ]
Lemos, Pedro Alves [1 ]
Nunes Sbano, Joao Cesar [1 ]
Franchini Ramires, Jose Antonio [1 ]
Tsutsui, Jeane Mike [2 ]
机构
[1] Univ Sao Paulo, Heart Inst InCor, Sch Med, BR-05403000 Sao Paulo, Brazil
[2] Univ Sao Paulo, Heart Inst InCor, Sch Med, Fleury Grp, BR-05403000 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
myocardial contrast echocardiography; cardiovascular magnetic resonance; coronary artery disease; stress test; CONSENSUS PANEL REPORT; EARLY INJECTION; CLINICAL-APPLICATIONS; AMERICAN-SOCIETY; ISCHEMIC CASCADE; PROGNOSTIC VALUE; ADDITIONAL VALUE; SAFETY; TIME; DIAGNOSIS;
D O I
10.1111/j.1540-8175.2012.01820.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recently, multimodality imaging has been demonstrated to improve the sensitivity of dobutamine stress for the diagnosis of coronary artery disease (CAD). Objective: We sought to determine the additional value of myocardial perfusion (MP) over wall-motion (WM) analysis for detecting CAD, using real time myocardial contrast echocardiography (RTMCE) and cardiovascular magnetic resonance (CMR), in the same group of patients. Methods: We studied 42 patients who underwent RTMCE and CMR during high-dose dobutamine stress with early injection of atropine. Results: No difference was observed in the diagnostic accuracy of RTMCE and CMR for detecting angiographically significant CAD when considering WM analysis alone (73% [95% CI, 65-81] and 78% [95% CI, 70-84], respectively; P = NS) or combined analysis of WM and MP (80% [95% CI, 73-97] and 83% [95% CI, 77-90], respectively; P = NS). Combined analysis of WM and MP had higher sensitivity than the analysis of WM alone by RTMCE (88% [95% CI, 75-100] vs. 72% [95% CI, 54-90]) and by CMR (92% [95% CI, 81-100] vs. 80% [95% CI, 64-96]) with no differences in specificity. The association of abnormal WM and MP abnormalities during high-dose dobutamine-atropine stress had additional value for detecting CAD over the analysis of WM alone, both by RTMCE (chi(2) = 16.16-24.13; P = 0.005) and CMR (chi(2) = 12.73-27.41; P = 0.001). Conclusion: RTMCE and CMR using the same dobutamine-atropine stress protocol had comparable diagnostic accuracies for the detection of angiographically significant CAD. MP imaging had additional value over WM analysis for the diagnosis of CAD, both at RTMCE and CMR. (Echocardiography 2013;30:45-54)
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [41] Incremental value of 2-dimensional speckle tracking strain imaging to wall motion analysis for detection of coronary artery disease in patients undergoing dobutamine stress echocardiography
    Ng, Arnold C. T.
    Sitges, Marta
    Pham, Phuong N.
    Tran, Da T.
    Delgado, Victoria
    Bertini, Matteo
    Nucifora, Gaetano
    Vidaic, Jane
    Allman, Christine
    Holman, Eduard R.
    Bax, Jeroen J.
    Leung, Dominic Y.
    AMERICAN HEART JOURNAL, 2009, 158 (05) : 836 - 844
  • [42] Value of combined dobutamine stress echocardiography and myocardial contrast echocardiography in determining prognosis of patients with known or suspected coronary artery disease
    Aggeli, C
    Rousakis, G
    Kokkinakis, C
    Brilli, S
    Latsios, G
    Barbetseas, J
    Pitsavos, C
    Stefanadis, C
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 294A - 295A
  • [43] REGIONAL CORRELATION BETWEEN TC-99M SESTAMIBI MYOCARDIAL PERFUSION DEFECTS AND FUNCTIONAL WALL-MOTION ABNORMALITIES ON ECHOCARDIOGRAPHY DURING DOBUTAMINE STRESS
    STEWART, RE
    DONOVAN, C
    MCALLISTER, SH
    SUTOR, RJ
    JUNI, JE
    GROSS, MD
    STARLING, MR
    CLINICAL RESEARCH, 1994, 42 (03): : A356 - A356
  • [44] Comparison of two-dimensional echocardiography and pulsed Doppler tissue imaging during dobutamine-atropine stress testing to detect coronary artery disease
    Peteiro, J
    Monserrat, L
    Fabregas, R
    Vázquez, JM
    Calviño, R
    Castro-Beiras, A
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (04): : 275 - 284
  • [45] Incremental prognostic value of dobutamine-atropine stress 99mTc-tetrofosmin myocardial perfusion imaging for predicting outcome in diabetic patients with limited exercise capacity
    Pedone, C
    Schinkel, AFL
    Elhendy, A
    van Domburg, RT
    Valkema, R
    Biagini, E
    Simoons, ML
    Bax, JJ
    Poldermans, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (09) : 1057 - 1063
  • [46] Effect of perfusion imaging during dobutamine stress echocardiography in detecting occult coronary artery disease in patients with advanced liver disease
    Tsutsui, JM
    Xie, F
    Mukherjee, S
    O'Leary, EL
    McGrain, AC
    Porter, TR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 294A - 294A
  • [47] Assessment of myocardial ischemia by strain dobutamine stress echocardiography and cardiac magnetic resonance perfusion imaging before and after coronary artery bypass grafting
    Rosner, Assami
    Schirmer, Henrik
    Iqbal, Amjid
    Bijnens, Bart
    Avenarius, Derk
    Malm, Siri
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (04): : 557 - 566
  • [48] Incremental Value of 18F-FDG Cardiac PET Imaging Over Dobutamine Stress Echocardiography in Predicting Myocardial Ischemia in Patients with Suspected Coronary Artery Disease
    Zampella, E.
    Assante, R.
    D'Antonio, A.
    Mannarino, T.
    Criscuolo, E.
    Bologna, R.
    Buongiorno, P.
    Gaudieri, V.
    Nappi, C.
    Green, R.
    Cantoni, V.
    Petretta, M.
    Acampa, W.
    Cuocolo, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S88 - S89
  • [49] Incremental value of 18F-FDG cardiac PET imaging over dobutamine stress echocardiography in predicting myocardial ischemia in patients with suspected coronary artery disease
    Emilia Zampella
    Roberta Assante
    Wanda Acampa
    Valeria Gaudieri
    Carmela Nappi
    Teresa Mannarino
    Adriana D’Antonio
    Pietro Buongiorno
    Mariarosaria Panico
    Ciro Gabriele Mainolfi
    Letizia Spinelli
    Mario Petretta
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2022, 29 : 3028 - 3038
  • [50] Incremental value of 18F-FDG cardiac PET imaging over dobutamine stress echocardiography in predicting myocardial ischemia in patients with suspected coronary artery disease
    Zampella, Emilia
    Assante, Roberta
    Acampa, Wanda
    Gaudieri, Valeria
    Nappi, Carmela
    Mannarino, Teresa
    D'Antonio, Adriana
    Buongiorno, Pietro
    Panico, Mariarosaria
    Mainolfi, Ciro Gabriele
    Spinelli, Letizia
    Petretta, Mario
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (06) : 3028 - 3038