Application of magneto-optic effects to measurements of currents in the environment of medium and high voltages

被引:0
|
作者
Blazejczyk, Tomasz [1 ]
Sibilski, Henryk [1 ]
Krasuski, Krzysztof [1 ]
机构
[1] Inst Elektrotech, Zaklad Wielkich Mocy, PL-04703 Warsaw, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2012年 / 88卷 / 11B期
关键词
magnetic field; magneto-optic effect; fibre optic sensor; measurement of current; MAGNETIC-FIELD; SENSOR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents results of investigations relating application of an optical sensor to the measurement of current in the environment of medium and high voltages. In the investigations was used optical fibre as the optical sensor of the magnetic field in shape of the optical fibre coil. Investigated of the magnetic field. The magnetic field source was the current (I-max = 11 kA) as the effect of discharging of capacitor bank (UBKmax = 11 kV). The influence of design of an optical sensor on his metrological properties was analysed on the basis of the results of investigations and the existing state of knowledge. (Application of magneto-optic effects to measurements of currents in the environment of medium and high voltages).
引用
收藏
页码:237 / 239
页数:3
相关论文
共 50 条
  • [31] Temporal Faraday and Other Magneto-Optic Effects
    Mendonca, Jose Tito
    PHOTONICS, 2025, 12 (02)
  • [32] Nonlinear magneto-optic effects with ultranarrow widths
    Budker, D
    Yashchuk, V
    Zolotorev, R
    PHYSICAL REVIEW LETTERS, 1998, 81 (26) : 5788 - 5791
  • [33] Comparison of the effects of surface plasmon resonance and the transverse magneto-optic Kerr effect in magneto-optic plasmonic nanostructures
    Rizal, Conrad
    Kapralov, Pavel O.
    Ignatyeva, Daria
    Belotelov, Vladimir
    Pisana, Simone
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2020, 53 (02)
  • [34] Magneto-optic effects in a nonlinear photonic crystal
    Hu, B
    Wang, WZ
    PHYSICAL REVIEW B, 2002, 65 (16) : 1 - 7
  • [35] Magneto-optic and Electro-optic Effects in Electromagnetic Fields
    Weng, Zi-Hua
    PIERS 2011 MARRAKESH: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2011, : 1785 - 1789
  • [36] Modified Sagnac interferometer for high-sensitivity magneto-optic measurements at cryogenic temperatures
    Xia, Jing
    Beyersdorf, Peter T.
    Fejer, M. M.
    Kapitulnik, Aharon
    APPLIED PHYSICS LETTERS, 2006, 89 (06)
  • [37] High-field magneto-optic measurements of amorphous Gd-Si alloys
    Hellman, F
    Geerts, W
    Donehew, B
    PHYSICAL REVIEW B, 2003, 67 (01)
  • [38] Chopped nonlinear magneto-optic rotation: A technique for precision measurements
    Ravishankar, Harish
    Chanu, Sapam Ranjita
    Natarajan, Vasant
    EPL, 2011, 94 (05)
  • [39] SMALL REGION MAGNETO-OPTIC MEASUREMENTS OF PERMALLOY I BARS
    HUIJER, E
    DOVE, DB
    WATSON, JK
    JOURNAL OF APPLIED PHYSICS, 1978, 49 (03) : 1903 - 1905
  • [40] Miniaturized magneto-optic sensor for pulsed magnetic field measurements
    Saxena, A. K.
    Kaushik, T. C.
    Nalini, N.
    Rawool, A. M.
    Gupta, S. C.
    APPLIED OPTICS, 2008, 47 (16) : 3048 - 3052