The lightning performance of overhead transmission lines is measured with the probability of backflashover. This probability is affected by (a) tower type, (b) grounding arrangement, (c) soil resistivity and (d) lightning activity and lightning parameters of the area. This paper presents an integrated model of the transmission towers, tower grounding and overhead line conductors. The model is utilized in a Monte Carlo simulation for the purpose of predicting the lightning performance of a transmission line. This paper presents the models and the simulation method. Typical results for typical transmission towers and grounding arrangements are provided. The model reveals that the grounding arrangement as well as the surge impedance of the transmission tower are important parameters affecting line performance. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:229 / 234
页数:6
相关论文
共 50 条
  • [41] Conductor optimisation for overhead transmission lines
    Dama, Dipeen
    Muftic, Dzevad
    Vajeth, Riaz
    IEEE Power Engineering Society Inaugural 2005 Conference and Exposition in Africa, 2005, : 410 - 416
  • [42] Compact Controllable Overhead Transmission Lines
    Postolatiy, V. M.
    PROBLEMELE ENERGETICII REGIONALE, 2019, (1-3): : 68 - 85
  • [43] STUDY ON THE INSULATION DESIGN OF OVERHEAD DC LINES.
    Watanabe, Y.
    IEEE Transactions on Power Apparatus and Systems, 1976, PAS-95 (04): : 1473 - 1479
  • [44] Validation of a Thermal Model for Overhead Transmission Lines at High Conductor Temperature
    Alvarez, J. Rodriguez
    Anderson, J. Azurza
    Franck, C. M.
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [45] Conductor optimisation for overhead transmission lines
    Vajeth, R
    Dama, D
    2004 IEEE AFRICON: 7TH AFRICON CONFERENCE IN AFRICA, VOLS 1 AND 2: TECHNOLOGY INNOVATION, 2004, : 589 - 595
  • [46] INSULATION OF OVERHEAD TRANSMISSION-LINES BETWEEN 110-KV AND 380-KV IN GDR
    DORR, H
    ENERGIETECHNIK, 1978, 28 (08): : 301 - 302
  • [47] Assessment of Overvoltage and Insulation Coordination in Mixed HVDC Transmission Lines Exposed to Lightning Strikes
    Asif, Mansoor
    Lee, Ho-Yun
    Park, Kyu-Hoon
    Shakeel, Ayesha
    Lee, Bang-Wook
    ENERGIES, 2019, 12 (21)
  • [48] OVERHEAD TRANSMISSION - LIGHTNING PERFORMANCE OF TRANSMISSION-LINES
    不详
    EPRI JOURNAL, 1983, 8 (08): : 44 - 44
  • [49] Monte Carlo method for estimating backflashover rates on high voltage transmission lines
    Sarajcev, Petar
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 119 : 247 - 257
  • [50] The Impact of the Distribution of Lightning Strikes along the Span on Backflashover Rate of Transmission Lines
    Silveira, Fernando H.
    Visacro, Silverio
    Gomes, Rafael M.
    Ono, Rafael S.
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,