Electron trapping variations in single-crystal pixelated HgI2 gamma-ray spectrometers

被引:0
|
作者
Baciak, JE [1 ]
He, Z [1 ]
Devito, RP [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The characteristics of thick (>5mm) HgI2 room temperature gamma-ray detectors having 4 small pixel anodes are investigated. Spectra for the different anodes (overall and for individual interaction depths) are presented. The mu-tau product for electrons was measured to study the variations of electron transport within a single HgI2 crystal. By using the single polarity charge sensing with depth sensing, the mu(e)tau(e) was estimated to vary from similar to9 x 10(4) cm(2)/V to 7 x 10(-3) cm(2)/V. Individual pixels have the ability to produce spectra with resolutions less than 3% at 662 keV. Some effects of electron detrapping and hole transport are also discussed.
引用
收藏
页码:2335 / 2339
页数:5
相关论文
共 50 条
  • [41] Development of Gamma Ray Imaging Systems using Mercuric Iodide (HgI2)
    van den Berg, L.
    Vigil, R. D.
    Bastian, L. F.
    Austin, R. A.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4984 - 4987
  • [42] Study the effect of gamma-ray irradiation on the optical properties of HgI2 thin film using method solvent evaporation
    Omer, Noor K.
    Zamel, Rafid S.
    Hussein, Adi M. Abdul
    PHYSICA SCRIPTA, 2021, 96 (01)
  • [43] Characterization of large single-crystal gamma-ray detectors of cadmium zinc telluride
    A. Burger
    M. Groza
    Y. Cui
    D. Hillman
    E. Brewer
    A. Bilikiss
    G. W. Wright
    L. Li
    F. Lu
    R. B. James
    Journal of Electronic Materials, 2003, 32 : 756 - 760
  • [44] Characterization of large single-crystal gamma-ray detectors of cadmium zinc telluride
    Burger, A
    Groza, M
    Cui, Y
    Hillman, D
    Brewer, E
    Bilikiss, A
    Wright, GW
    Li, L
    Fu, F
    James, RB
    JOURNAL OF ELECTRONIC MATERIALS, 2003, 32 (07) : 756 - 760
  • [45] SEARCH FOR IMPROVED SURFACE-TREATMENT PROCEDURES IN FABRICATION OF HGI2 X-RAY SPECTROMETERS
    LEVI, A
    BURGER, A
    NISSENBAUM, J
    SCHIEBER, M
    BURSHTEIN, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (01): : 35 - 38
  • [46] NEW CONCEPTS FOR SCINTILLATOR/HGI(2) GAMMA-RAY SPECTROSCOPY
    WANG, YJ
    IWANCZYK, JS
    PATT, BE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 910 - 914
  • [47] ENERGY RESOLUTION OF HGI2 DETECTORS OF X-RAY AND GAMMA-QUANTA
    ZALETIN, VM
    KRIVOZUBOV, OV
    TORLIN, MA
    FOMIN, VI
    SOVIET ATOMIC ENERGY, 1987, 63 (02): : 652 - 655
  • [48] THE INFLUENCE OF ELECTRON MOMENTUM ON THE SHAPE OF BACKSCATTER PEAKS IN GAMMA-RAY SPECTROMETERS
    MACKENZIE, IK
    HURST, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 242 (01): : 137 - 142
  • [49] INVESTIGATION OF SINGLE-CRYSTAL HIGH-RESISTIVITY CADMIUM TELLURIDE AS A GAMMA-RAY SPECTROMETER
    BAILY, NA
    ANDRES, RJ
    NUCLEAR APPLICATIONS, 1968, 4 (05): : 337 - &
  • [50] ANISOTROPIC GAMMA-RAY RESONANCE SCATTERING FROM A ZINC SINGLE-CRYSTAL AND THE UNCERTAINTY PRINCIPLE
    MOREH, R
    FOGEL, M
    PHYSICAL REVIEW B, 1994, 50 (22): : 16184 - 16191