Electron trapping variations in single-crystal pixelated HgI2 gamma-ray spectrometers

被引:0
|
作者
Baciak, JE [1 ]
He, Z [1 ]
Devito, RP [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The characteristics of thick (>5mm) HgI2 room temperature gamma-ray detectors having 4 small pixel anodes are investigated. Spectra for the different anodes (overall and for individual interaction depths) are presented. The mu-tau product for electrons was measured to study the variations of electron transport within a single HgI2 crystal. By using the single polarity charge sensing with depth sensing, the mu(e)tau(e) was estimated to vary from similar to9 x 10(4) cm(2)/V to 7 x 10(-3) cm(2)/V. Individual pixels have the ability to produce spectra with resolutions less than 3% at 662 keV. Some effects of electron detrapping and hole transport are also discussed.
引用
收藏
页码:2335 / 2339
页数:5
相关论文
共 50 条
  • [1] Electron trapping variations in single-crystal pixelated HgI2 gamma-ray spectrometers
    Baciak, JE
    He, Z
    DeVito, RP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1264 - 1269
  • [2] Large volume HgI2 gamma-ray spectrometers
    He, Z
    Baciak, J
    UNATTENDED RADIATION SENSOR SYSTEMS FOR REMOTE APPLICATIONS, 2002, 632 : 113 - 117
  • [3] Long-term stability of pixelated HgI2 gamma-ray spectrometers operating at room temperature
    Baciak, JE
    He, Z
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3545 - 3549
  • [4] 1 cm thick HgI2 gamma-ray spectrometers
    Baciak, JE
    He, Z
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3532 - 3536
  • [5] EFFECT OF HGI2 CRYSTAL NONUNIFORMITIES ON GAMMA-RAY RESPONSE
    JAMES, K
    GERRISH, V
    CROSS, E
    MARKAKIS, J
    MARSCHALL, J
    MILSTEIN, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 390 - 401
  • [6] HIGH-EFFICIENCY CSI(TL)HGI2 GAMMA-RAY SPECTROMETERS
    WANG, YJ
    PATT, BE
    IWANCZYK, JS
    CHERRY, SR
    SHAO, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 601 - 605
  • [7] Comparison of 5 and 10 mm thick HgI2 pixelated γ-ray spectrometers
    Baciak, JE
    He, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 191 - 194
  • [8] THE EFFECT OF CHARGE TRAPPING ON THE SPECTROMETRIC PERFORMANCE OF HGI2 GAMMA-RAY DETECTORS
    IWANCZYK, JS
    SCHNEPPLE, WF
    MASTERSON, MJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 421 - 426
  • [9] CRYSTAL PERFECTION OF HGI2 STUDIED BY NEUTRON AND GAMMA-RAY DIFFRACTION
    YELON, WB
    ALKIRE, RW
    SCHIEBER, MM
    VANDENBERG, L
    RASMUSSEN, SE
    CHRISTENSEN, H
    SCHNEIDER, JR
    JOURNAL OF APPLIED PHYSICS, 1981, 52 (07) : 4604 - 4609
  • [10] Long-term stability of 1-cm thick pixelated HgI2 gamma-ray spectrometers operating at room temperature
    Baciak, JE
    He, Z
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1886 - 1894