A Novel Aggregation Method for Doubly Fed Wind Farm

被引:0
|
作者
Li, Lulu [1 ]
Han, Xueshan [1 ]
Li, Wenbo [2 ]
Jiang, Zhe [2 ]
机构
[1] Shandong Univ, Minist Educ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan, Shandong, Peoples R China
[2] State Grid Shandong Elect Power Res Inst, Jinan 250003, Shandong, Peoples R China
关键词
D O I
10.1088/1742-6596/1187/2/022053
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the increasing penetration of wind power, many problems like frequency and voltage stability appear frequently, so the power grid gradually requires that the wind farm can be dispatched and controlled. In this paper, a new aggregation method is proposed to calculate the aggregated active and reactive power regulation range of a doubly-fed wind farm, which provides a dispatching reference for the power system control center. In this method, voltage security and different operation states of wind turbines and internal power losses of the wind farm are considered. Finally, the actual aggregated P-Q regulation range of the wind farm that can ensure operation safety is obtained. A wind farm with 25 doubly fed induction generator (DFIG) wind turbines is used to verify the proposed aggregation method.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Coordinated control method of virtual inertia and virtual damping for interconnected power system with doubly-fed wind farm
    Yang T.
    Liao Y.
    1600, Electric Power Automation Equipment Press (40): : 92 - 98
  • [22] A New Short-Circuit Current Calculation and Fault Analysis Method Suitable for Doubly Fed Wind Farm Groups
    Yin, Jun
    Qian, Weichen
    Huang, Xiaobo
    SENSORS, 2023, 23 (20)
  • [23] MPPT of Doubly-fed Induction Generator in Wind Farm Using SPSA Algorithm
    Kuang Hong-hai
    Wu Zheng-qiu
    Li Sheng-qing
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 662 - +
  • [24] Modeling and Fault Analysis of Doubly Fed Induction Generators for Gansu Wind Farm Application
    Kheshti, Mostafa
    Kang, Xiaoning
    Song, Guobing
    Jiao, Zaibin
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2015, 38 (01): : 52 - 64
  • [25] Transient voltage control system and RTDS test for doubly-fed wind farm
    Li, Shaohua
    Zhang, Ailing
    Zhang, Chongjian
    Hao, Zhenghang
    Zhang, Wang
    Chai, Jianyun
    Yao, Zhiqing
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2014, 34 (09): : 137 - 142
  • [26] Wind Farm Stabilization with Dual-purpose Doubly-Fed Asynchronous Machine
    Wu, Li
    Li, Xiangjun
    Liu, Zhenxing
    Zhou, Hongjun
    Chen, Lin
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 940 - +
  • [27] Dynamic equivalent model of doubly fed wind farm during electromagnetic transient process
    Jinxin, Ouyang
    Yanbo, Diao
    Di, Zheng
    Rui, Yu
    Xi, Zhang
    Xiaofu, Xiong
    IET RENEWABLE POWER GENERATION, 2017, 11 (01) : 100 - 106
  • [28] . A novel Control Method of Grid Connected Doubly Fed Induction Generator Under Variable Wind Speed
    Elhassan, Zakieldeen
    Yia, Tang
    Yang, Li
    2013 INTERNATIONAL CONFERENCE ON COMPUTING, ELECTRICAL AND ELECTRONICS ENGINEERING (ICCEEE), 2013, : 92 - 98
  • [29] Coordinated control of an HVDC link and doubly fed induction generators in a large offshore wind farm
    Xiang, DW
    Ran, L
    Bumby, JR
    Tavner, PJ
    Yang, SC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) : 463 - 471
  • [30] Real-Time Implementation of a STATCOM on a Wind Farm Equipped With Doubly Fed Induction Generators
    Qiao, Wei
    Venayagamoorthy, Ganesh Kumar
    Harley, Ronald G.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (01) : 98 - 107