Using flow information to support 3D vessel reconstruction from rotational angiography

被引:8
|
作者
Waechter, Irina [1 ]
Bredno, Joerg [2 ]
Weese, Juergen [2 ]
Barratt, Dean C. [1 ]
Hawkes, David J. [1 ]
机构
[1] UCL, Ctr Med Image Comp, London WC1E 6BT, England
[2] Philips Res Europe, Aachen, Germany
关键词
rotational angiography; blood flow; 3D reconstruction; vessel segmentation;
D O I
10.1118/1.2938729
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information can be determined when the angiographic sequence shows inflow and possibly outflow of contrast agent. However, a standard volume reconstruction assumes that the vessel tree is uniformly filled with contrast agent during the whole acquisition. If this is not the case, the reconstruction exhibits artifacts. Here, we show how flow information can be used to support the reconstruction of the 3D vessel centerline and radii in this case. Our method uses the fast marching algorithm to determine the order in which voxels are analyzed. For every voxel, the rotational time intensity curve (R-TIC) is determined from the image intensities at the projection points of the current voxel. Next, the bolus arrival time of the contrast agent at the voxel is estimated from the R-TIC. Then, a measure of the intensity and duration of the enhancement is determined, from which a speed value is calculated that steers the propagation of the fast marching algorithm. The results of the fast marching algorithm are used to determine the 3D centerline by backtracking. The 3D radius is reconstructed from 2D radius estimates on the projection images. The proposed method was tested on computer simulated rotational angiography sequences with systematically varied x-ray acquisition, blood flow, and contrast agent injection parameters and on datasets from an experimental setup using an anthropomorphic cerebrovascular phantom. For the computer simulation, the mean absolute error of the 3D centerline and 3D radius estimation was 0.42 and 0.25 mm, respectively. For the experimental datasets, the mean absolute error of the 3D centerline was 0.45 mm. Under pulsatile and nonpulsatile conditions, flow information can be used to enable a 3D vessel reconstruction from rotational angiography with inflow and possibly outflow of contrast agent. We found that the most important parameter for the quality of the reconstruction of centerline and radii is the range through which the x-ray system rotates in the time span of the injection. Good results were obtained if this range was at least 135 degrees. As a standard c-arm can rotate 205 degrees, typically one third of the acquisition can show inflow or outflow of contrast agent, which is required for the quantification of blood flow from rotational angiography. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3302 / 3316
页数:15
相关论文
共 50 条
  • [21] 3D VESSEL RECONSTRUCTION IN OCT-ANGIOGRAPHY VIA DEPTH MAP ESTIMATION
    Yu, Shuai
    Xie, Jianyang
    Hao, Jinkui
    Zheng, Yalin
    Zhang, Jiong
    Hu, Yan
    Liu, Jiang
    Zhao, Yitian
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 1609 - 1613
  • [22] 3D reconstruction of coronary artery using biplane angiography
    Law, AKW
    Zhu, H
    Chan, FHY
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 533 - 536
  • [23] 3D Vessel Tree Reconstruction from Rotational C-arm Projections by Multi-view Stereo Reconstruction
    Zhang, Wei
    Chen, Zikuan
    Zhang, Xuefeng
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 434 - +
  • [24] Cerebral aneurysm hemodynamics modeling from 3D rotational angiography
    Cebral, JR
    Castro, MA
    Burgess, JE
    Putman, CM
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 944 - 947
  • [25] Automatic trinocular 3D reconstruction of coronary artery centerlines from rotational X-ray angiography
    Blondel, C
    Vaillant, R
    Devernay, F
    Malandain, G
    Ayache, N
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 832 - 837
  • [26] 3D Liver Vessel Reconstruction from CT Images
    Pan, Xing-Chen
    Su, Hong-Ren
    Lai, Shang-Hong
    Liu, Kai-Che
    Wu, Hurng-Sheng
    2014 2ND INTERNATIONAL CONFERENCE ON 3D VISION, VOL. 2, 2014, : 75 - 81
  • [27] A method for 3D flow determination based on X-ray rotational angiography
    Grass, M
    Schmitt, H
    Rasche, V
    Haehnel, S
    Schramm, O
    Hartmann, M
    Sartor, K
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 390 - 395
  • [28] CT reconstruction and MRI fusion of 3D rotational angiography in the evaluation of pediatric cerebrovascular lesions
    Muthusami, Prakash
    Shkumat, Nicholas
    Rea, Vanessa
    Chiu, Albert H.
    Shroff, Manohar
    NEURORADIOLOGY, 2017, 59 (06) : 625 - 633
  • [29] CT reconstruction and MRI fusion of 3D rotational angiography in the evaluation of pediatric cerebrovascular lesions
    Prakash Muthusami
    Nicholas Shkumat
    Vanessa Rea
    Albert H. Chiu
    Manohar Shroff
    Neuroradiology, 2017, 59 : 625 - 633
  • [30] Pre-embolization study of ruptured cerebral aneurysm with rotational and 3D reconstruction angiography
    Castaño-Duque, CH
    Guardia-Mas, E
    de Juan-Delago, M
    Ruscalleda-Nadal, J
    DEVELOPMENTS IN NEUROSCIENCE, PROCEEDINGS, 2002, 1247 : 39 - 52