[18F]FDG uptake of the normal spinal cord in PET/MR imaging: comparison with PET/CT imaging

被引:7
|
作者
Aiello, Marco [1 ]
Alfano, Vincenzo [1 ]
Salvatore, Elena [2 ]
Cavaliere, Carlo [1 ]
Picardi, Marco [3 ]
Della Pepa, Roberta [3 ]
Nicolai, Emanuele [1 ]
Soricelli, Andrea [1 ]
Vella, Alessandra [4 ]
Salvatore, Marco [1 ]
Mascalchi, Mario [5 ]
机构
[1] IRCCS SDN, Naples, Italy
[2] Univ Naples Federico II, Dept Neurosci, Naples, Italy
[3] Dept Clin Med & Surg, Hematol Sect, Naples, Italy
[4] Le Scotte Hosp Siena, Nucl Med, Siena, Italy
[5] Univ Florence, Mario Serio Dept Expt & Clin Biomed Sci, Florence, Italy
关键词
FDG; PET; MRI; Spinal cord; SUV; EMISSION-TOMOGRAPHY; METABOLISM; SUV;
D O I
10.1186/s13550-020-00680-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The lack of visualization of the spinal cord hinders the evaluation of [F-18]Fluoro-deoxy-glucose (FDG) uptake of the spinal cord in PET/CT. By exploiting the capability of MRI to precisely outline the spinal cord, we performed a retrospective study aimed to define normal pattern of spinal cord [F-18]FDG uptake in PET/MRI. Methods Forty-one patients with lymphoma without clinical or MRI signs of spinal cord or bone marrow involvement underwent simultaneous PET and MRI acquisition using Siemens Biograph mMR after injection of 3.5 MBq/kg body weight of [F-18]FDG for staging purposes. Using a custom-made software, we placed ROIs of 3 and 9 mm in diameter in the spinal cord, lumbar CSF, and vertebral marrow that were identified on MRI at 5 levels (C2, C5, T6, T12, and L3). The SUVmax, SUVmean, and the SUVmax and SUVmean normalized (NSUVmax and NSUVmean) to the liver were measured. For comparison, the same ROIs were placed in PET-CT images obtained immediately before the PET-MRI acquisition following the same tracer injection. Results On PET/MRI using the 3 mm ROI, the following average (all level excluding L3) spinal cord median (1st and 3rd quartile) values were measured: SUVmean, 1.68 (1.39 and 1.83); SUVmax, 1.92 (1.60 and 2.14); NSUVmean, 1.18 (0.93 and 1.36); and NSUVmax, 1.27 (1.01 and 1.33). Using the 9 mm ROI, the corresponding values were SUVmean, 1.41 (1.25-1.55); SUVmax, 2.41 (2.08 and 2.61); NSUVmean, 0.93 (0.79 and 1.04); and NSUVmax, 1.28 (1.02 and 1.39). Using the 3 mm ROI, the highest values of PET-MRI SUVmax, SUVmean, NSUVmax, and NSUVmean were consistently observed at C5 and the lowest at T6. Using a 9 mm ROI, the highest values were consistently observed at C5 and the lowest at T12 or T6. The spinal cord [F-18]FDG-uptake values correlated with the bone marrow uptake at the same level, especially in case of NSUVmax. Comparison with PET-CT data revealed that the average SUVmax and SUVmean of the spinal cord were similar in PET-MRI and PET-CT. However, the average NSUVmax and NSUVmean of the spinal cord were higher (range 21-47%) in PET-MRI than in PET-CT. Conclusions Using a whole-body protocol, we defined the maximum and mean [F-18]FDG uptake of the normal spinal cord in PET/MRI. While the observed values show the expected longitudinal distribution, they appear to be higher than those measured in PET/CT. Normalization of the SUVmax and SUVmean of the spinal cord to the liver radiotracer uptake could help in multi-institutional comparisons and studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Updates on MR imaging and 18F-FDG PET/CT imaging in nasopharyngeal carcinoma
    Lai, Vincent
    Khong, Pek Lan
    ORAL ONCOLOGY, 2014, 50 (06) : 539 - 548
  • [22] On the factors affecting the liver SUV in [18F]FDG PET/CT imaging
    Laffon, Eric
    de Clermont, Henri
    Marthan, Roger
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (03) : 650 - 651
  • [23] [18F]FDG PET/CT imaging of colorectal cancer: a pictorial review
    Chowdhury, Fahmid U.
    Shah, Nehal
    Scarsbrook, Andrew F.
    Bradley, Kevin M.
    POSTGRADUATE MEDICAL JOURNAL, 2010, 86 (1013) : 174 - 182
  • [24] On the factors affecting the liver SUV in [18F]FDG PET/CT imaging
    Eric Laffon
    Henri de Clermont
    Roger Marthan
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 650 - 651
  • [25] Imaging acute spinal myelitis with 18F-FDG PET/CT
    Egesta Lopci
    Marcello Rodari
    Giovanna Pepe
    Lidija Antunovic
    Arturo Chiti
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 399 - 400
  • [26] Imaging acute spinal myelitis with 18F-FDG PET/CT
    Lopci, Egesta
    Rodari, Marcello
    Pepe, Giovanna
    Antunovic, Lidija
    Chiti, Arturo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (02) : 399 - 400
  • [27] [18F]FDG and [18F]FLT PET-CT and MR Imaging of Human Neuroblastomas in a SCID Mouse Xenograft Model
    Valentiner, Ursula
    Haane, Christina
    Peldschus, Kersten
    Gustke, Heike
    Brenner, Winfried
    Wilke, Florian
    Pommert, Andreas
    Owsijewitsch, Michael
    Schumacher, Udo
    Klutmann, Susanne
    ANTICANCER RESEARCH, 2008, 28 (5A) : 2561 - 2568
  • [28] 18F-FDG PET/CT Imaging Artifacts and Normal Variants
    Martins, M. Casanova
    Correia, J.
    Lapa, P.
    Costa, G.
    Pedroso de Lima, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S620 - S621
  • [29] Comparison of Whole-Body 18F FDG PET/MR Imaging and Whole-Body 18F FDG PET/CT in Terms of Lesion Detection and Radiation Dose in Patients with Breast Cancer
    Melsaether, Amy N.
    Raad, Roy A.
    Pujara, Akshat C.
    Ponzo, Fabio D.
    Pysarenko, Kristine M.
    Jhaveri, Komal
    Babb, James S.
    Sigmund, Eric E.
    Kim, Sungheon G.
    Moy, Linda A.
    RADIOLOGY, 2016, 281 (01) : 193 - 202
  • [30] [18F]FAPI-42 PET/CT versus [18F]FDG PET/CT for imaging of recurrent or metastatic gastrointestinal stromal tumors
    Chunhui Wu
    Xinhua Zhang
    Yu Zeng
    Renbo Wu
    Li Ding
    Yanzhe Xia
    Zhifeng Chen
    Xiangsong Zhang
    Xiaoyan Wang
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 50 : 194 - 204