[18F]FDG uptake of the normal spinal cord in PET/MR imaging: comparison with PET/CT imaging

被引:7
|
作者
Aiello, Marco [1 ]
Alfano, Vincenzo [1 ]
Salvatore, Elena [2 ]
Cavaliere, Carlo [1 ]
Picardi, Marco [3 ]
Della Pepa, Roberta [3 ]
Nicolai, Emanuele [1 ]
Soricelli, Andrea [1 ]
Vella, Alessandra [4 ]
Salvatore, Marco [1 ]
Mascalchi, Mario [5 ]
机构
[1] IRCCS SDN, Naples, Italy
[2] Univ Naples Federico II, Dept Neurosci, Naples, Italy
[3] Dept Clin Med & Surg, Hematol Sect, Naples, Italy
[4] Le Scotte Hosp Siena, Nucl Med, Siena, Italy
[5] Univ Florence, Mario Serio Dept Expt & Clin Biomed Sci, Florence, Italy
关键词
FDG; PET; MRI; Spinal cord; SUV; EMISSION-TOMOGRAPHY; METABOLISM; SUV;
D O I
10.1186/s13550-020-00680-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background The lack of visualization of the spinal cord hinders the evaluation of [F-18]Fluoro-deoxy-glucose (FDG) uptake of the spinal cord in PET/CT. By exploiting the capability of MRI to precisely outline the spinal cord, we performed a retrospective study aimed to define normal pattern of spinal cord [F-18]FDG uptake in PET/MRI. Methods Forty-one patients with lymphoma without clinical or MRI signs of spinal cord or bone marrow involvement underwent simultaneous PET and MRI acquisition using Siemens Biograph mMR after injection of 3.5 MBq/kg body weight of [F-18]FDG for staging purposes. Using a custom-made software, we placed ROIs of 3 and 9 mm in diameter in the spinal cord, lumbar CSF, and vertebral marrow that were identified on MRI at 5 levels (C2, C5, T6, T12, and L3). The SUVmax, SUVmean, and the SUVmax and SUVmean normalized (NSUVmax and NSUVmean) to the liver were measured. For comparison, the same ROIs were placed in PET-CT images obtained immediately before the PET-MRI acquisition following the same tracer injection. Results On PET/MRI using the 3 mm ROI, the following average (all level excluding L3) spinal cord median (1st and 3rd quartile) values were measured: SUVmean, 1.68 (1.39 and 1.83); SUVmax, 1.92 (1.60 and 2.14); NSUVmean, 1.18 (0.93 and 1.36); and NSUVmax, 1.27 (1.01 and 1.33). Using the 9 mm ROI, the corresponding values were SUVmean, 1.41 (1.25-1.55); SUVmax, 2.41 (2.08 and 2.61); NSUVmean, 0.93 (0.79 and 1.04); and NSUVmax, 1.28 (1.02 and 1.39). Using the 3 mm ROI, the highest values of PET-MRI SUVmax, SUVmean, NSUVmax, and NSUVmean were consistently observed at C5 and the lowest at T6. Using a 9 mm ROI, the highest values were consistently observed at C5 and the lowest at T12 or T6. The spinal cord [F-18]FDG-uptake values correlated with the bone marrow uptake at the same level, especially in case of NSUVmax. Comparison with PET-CT data revealed that the average SUVmax and SUVmean of the spinal cord were similar in PET-MRI and PET-CT. However, the average NSUVmax and NSUVmean of the spinal cord were higher (range 21-47%) in PET-MRI than in PET-CT. Conclusions Using a whole-body protocol, we defined the maximum and mean [F-18]FDG uptake of the normal spinal cord in PET/MRI. While the observed values show the expected longitudinal distribution, they appear to be higher than those measured in PET/CT. Normalization of the SUVmax and SUVmean of the spinal cord to the liver radiotracer uptake could help in multi-institutional comparisons and studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] [18F]FDG uptake of the normal spinal cord in PET/MR imaging: comparison with PET/CT imaging
    Marco Aiello
    Vincenzo Alfano
    Elena Salvatore
    Carlo Cavaliere
    Marco Picardi
    Roberta Della Pepa
    Emanuele Nicolai
    Andrea Soricelli
    Alessandra Vella
    Marco Salvatore
    Mario Mascalchi
    EJNMMI Research, 10
  • [2] [18F]FDG PET/CT imaging of spinal infections
    te Beek, Erik T.
    ten Broek, Marc R. J.
    Abdul-Fatah, Sakar
    Glaudemans, Andor W. J. M.
    CLINICAL AND TRANSLATIONAL IMAGING, 2024, 12 (05) : 527 - 539
  • [3] Hibernoma:: 18F FDG PET/CT imaging
    Subramaniam, Rathan M.
    Clayton, Amy C.
    Karantanis, Dimitrios
    Collins, Douglas A.
    JOURNAL OF THORACIC ONCOLOGY, 2007, 2 (06) : 569 - 570
  • [4] Robustness of radiomic features in [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Vuong, D.
    Bogowicz, M.
    Huellner, M.
    Veit-Haibach, P.
    Andratschke, N.
    Unkelbach, J.
    Guckenberger, M.
    Tanadini-Lang, S.
    JOURNAL OF THORACIC ONCOLOGY, 2018, 13 (04) : S41 - S41
  • [5] Evaluation of Gynecologic Cancer with MR Imaging, 18F-FDG PET/CT, and PET/MR Imaging
    Lee, Susanna I.
    Catalano, Onofrio A.
    Dehdashti, Farrokh
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 436 - 443
  • [6] Comparison of 18F-FDG-PET/CT and 18F-FDG-PET/MR imaging in oncology: a systematic review
    Amit Singnurkar
    Raymond Poon
    Ur Metser
    Annals of Nuclear Medicine, 2017, 31 : 366 - 378
  • [7] Comparison of 18F-FDG-PET/CT and 18F-FDG-PET/MR imaging in oncology: a systematic review
    Singnurkar, Amit
    Poon, Raymond
    Metser, Ur
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (05) : 366 - 378
  • [8] Comparison of PET/MR and PET/CT Hybrid imaging with [18F]-FDG as a Basis for an automatic Contouring of Target volume for IMRT
    Thorwarth, D.
    Welz, S.
    Schmidt, H.
    Pfannenberg, C.
    Schwenzer, N.
    Mueller, A-C
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 10 - 10
  • [9] Robustness study on radiomic features in [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Vuong, D.
    Bogowicz, M.
    Huellner, M.
    Veit-Haibach, P.
    Andratschke, N.
    Unkelbach, J.
    Guckenberger, M.
    Tanadini-Lang, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1159 - S1159
  • [10] Interchangeability of radiomic features between [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Diem Vuong
    Tanadini-Lang, Stephanie
    Huellner, Martin W.
    Veit-Haibach, Patrick
    Unkelbach, Jan
    Andratschke, Nicolaus
    Kraft, Johannes
    Guckenberger, Matthias
    Bogowicz, Marta
    MEDICAL PHYSICS, 2019, 46 (04) : 1677 - 1685