Enhancement of heat transfer by an air/water spray in a transformer oil cooler

被引:0
|
作者
Lang, SK [1 ]
Bergles, AE [1 ]
机构
[1] Raytheon Syst Co, Sudbury, MA 01776 USA
关键词
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Water has been used for many years by the power industry to cool overheated transformers. Transformer oil coolers are compact finned-tube heat exchangers. However, the quantity of water applied to the oil coolers has not been optimized. This has motivated the present research to investigate the effects of water spray on a transformer cooler. The development of an experimental test facility consisting of a full-scale oil transformer cooler is described. An experimental program was carried out to evaluate the performance of a cooler under air-cooled conditions and deluged-water conditions. Significant performance enhancement was found by spraying relatively small amounts of water onto the heat exchanger. Tests were performed for various air velocities, oil flow rates, and water spray now rates. From the air-cooled data, individual airside heat transfer coefficients were "backed-out" for each row of tubes. A model was then developed to predict the local air/water-cooled performance that incorporates the heat and-mass-transfer analogy to determine the water evaporation rates. For this "wet" model, the water distribution is a required input. The inlet (top) oil temperatures thus predicted are in good agreement with the experimental values.
引用
收藏
页码:367 / 376
页数:4
相关论文
共 50 条
  • [31] SIMULATION OF HEAT AND MASS TRANSFER IN INDIRECT EVAPORATIVE AIR-COOLER
    Barakov, A. V.
    Kozhukhov, N. N.
    Prutskikh, D. A.
    Dubanin, V. Yu.
    SCIENTIFIC HERALD OF THE VORONEZH STATE UNIVERSITY OF ARCHITECTURE & CIVIL ENGINEERING CONSTRUCTION & ARCHITECTURE, 2016, (02): : 24 - 29
  • [32] Effect of streaming potential on heat transfer in transformer oil
    Jayaram, S
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (03) : 410 - 416
  • [33] Experimental study on heat transfer enhancement of wavy finned flat tubes by water spray cooling
    Xiao, Liehui
    Wu, Tao
    Feng, Shuqin
    Du, Xiaoze
    Yang, Lijun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 110 : 383 - 392
  • [34] A novel coaxial air-R134a spray cooling for heat transfer enhancement of laser dermatology
    Qenawy, Mohamed
    Chen, Yiqi
    Zhu, Yuchen
    Ali, Mona
    Wang, Junfeng
    Tian, Jiameng
    Chen, Bin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 233
  • [35] Limited water-to-air bacterial transfer from a residential evaporative air cooler
    Environmental Health Laboratory Branch, Division of Environmental and Occupational Disease Control, California Department of Health Services, Berkeley, CA, United States
    ENVIRON. INT., 6 (761-764):
  • [36] LIMITED WATER-TO-AIR BACTERIAL TRANSFER FROM A RESIDENTIAL EVAPORATIVE AIR COOLER
    MACHER, JM
    GIRMAN, JR
    ALEVANTIS, LA
    ENVIRONMENT INTERNATIONAL, 1995, 21 (06) : 761 - 764
  • [37] Heat transfer enhancement in an air to water heat exchanger with discontinuous helical turbulators; experimental and numerical studies
    Sheikholeslami, M.
    Ganji, D. D.
    ENERGY, 2016, 116 : 341 - 352
  • [39] Heat and mass transfer processes between a water spray and ambient air - II. Simulations
    Sureshkumar, R.
    Kale, S. R.
    Dhar, P. L.
    APPLIED THERMAL ENGINEERING, 2008, 28 (5-6) : 361 - 371
  • [40] Plasma spray produced coatings for boiling heat transfer enhancement
    Tehver, J.
    Sui, H.
    International Journal of Materials and Product Technology, 1993, 8 (2-4) : 325 - 331