A New Simulation and Analysis for Low Voltage Ride Through Property of Wind Farm

被引:0
|
作者
Huang, Tao [1 ]
Lu, Yuping [1 ]
Cai, Chao [1 ]
Xu, Sixuan [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing, Jiangsu, Peoples R China
关键词
wind farm; low voltage ride through; fault period; dynamic voltage recovery; relay protection; dynamic load model; wind speed;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Large scale growth of wind power generation has brought about new challenges which require an urgent enhancement of low voltage ride through (LVRT) capability of wind farm to strengthen the stability of power grid. A number of studies have been performed recently to help wind turbines withstand overcurrent and overvoltage during the fault period, and some available measures have emerged. In this paper, a new simulation is carried out to analyze the factors which relate to the LVRT process especially dynamic voltage recovery period. The simulation results demonstrate that load model, relay protection operating time and wind speed are relevant to the duration of dynamic voltage recovery. Several methods are also proposed to curtail the duration of LVRT, which may provide basis for improving the LVRT capability of wind farm.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Bifurcation Analysis and Criteria of Voltage Oscillation Induced by Low Voltage Ride Through Control in Onshore Wind Farms
    Kong, He
    Hou, Shan
    Zhao, Yihan
    Yang, Jinzhou
    Li, Yecheng
    Wang, Jiawei
    Xue, Ancheng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (21): : 8475 - 8487
  • [32] Fault Characteristic and Low Voltage Ride-Through Requirements Applicability Analysis for a Permanent Magnet Synchronous Generator-Based Wind Farm
    Chen, Wei
    Zheng, Taiying
    Han, Junfei
    ENERGIES, 2019, 12 (17)
  • [33] Analysis on the low voltage ride through technology of DFIG
    Wang, Wei
    Sun, Mingdong
    Zhu, Xiaodong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2007, 31 (23): : 84 - 89
  • [34] The research of verifying Low voltage ride through of Double-fed wind turbine generator system and voltage dropping simulation
    Xing, Zuoxia
    Chen, Lei
    Xue, Lichen
    Zhang, Yongxing
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 2380 - +
  • [35] Fault Ride-through Capability of Wind Farm (Case Study of Adama Wind Farm Project, Dynamic Modeling and Simulation)
    Shobole, Abdulfetah
    Tanriove, Mugdesem
    2015 6TH INTERNATIONAL CONFERENCE ON MODELING, SIMULATION, AND APPLIED OPTIMIZATION (ICMSAO), 2015,
  • [36] Application of STATCOM-supercapacitor for low-voltage ride-through capability in DFIG-based wind farm
    Dosoglu, M. K.
    Arsoy, A. Basa
    Guvenc, U.
    NEURAL COMPUTING & APPLICATIONS, 2017, 28 (09): : 2665 - 2674
  • [37] Application of STATCOM-supercapacitor for low-voltage ride-through capability in DFIG-based wind farm
    M. K. Döşoğlu
    A. Basa Arsoy
    U. Güvenç
    Neural Computing and Applications, 2017, 28 : 2665 - 2674
  • [38] Coordinated Low Voltage Ride-Through of MMC-HVDC Transmission System and Wind Farm With Distributed Braking Resistors
    Wang, Xiaohe
    Yang, Renxin
    Shi, Zhaohui
    Cai, Xu
    Shi, Xianqiang
    Chen, Yuwei
    IEEE ACCESS, 2022, 10 : 87860 - 87869
  • [39] Reactive power control strategy of DFIG-based wind farm based on low voltage ride through ability evaluation
    Chen J.
    Wang Y.
    Li Q.
    Yin Q.
    Qin J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (04): : 466 - 472
  • [40] Feasibility Analysis on High Voltage Ride-Through of Wind Turbines
    Song, Fei
    Wang, Tong
    Tang, Kan
    Zhu, Dan
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 134 - 138