Modeling variability of force during isometric contractions of the quadriceps femoris

被引:85
|
作者
Christou, EA [1 ]
Grossman, M [1 ]
Carlton, LG [1 ]
机构
[1] Univ Colorado, Neural Control Movement Lab, Dept Kinesiol & Appl Physiol, Boulder, CO 80309 USA
关键词
force variability; isometric; lower body; modeling; quadriceps femoris;
D O I
10.1080/00222890209601932
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The authors modeled variability of force during continuous isometric contractions of the quadriceps femoris. Twenty adults (aged 25 6 years old) performed isometric leg extensions. Target forces were I I percentages of maximum voluntary contraction (%MVC), ranging from 2 to 95%, and 5 absolute levels, from 25 to 225 N. The authors used standard deviation of absolute force, coefficient of variation, and signal-to-noise ratio as measures of variability. The results suggested a nonlinear relationship between variability and level of force, which could best be expressed as %MVC and not as absolute force. Variability for continuous isometric contractions was described best by a sigmoidal logistic function. The sigmoidal pattern of variability as a function of %MVC is consistent with physiological mechanisms.
引用
收藏
页码:67 / 81
页数:15
相关论文
共 50 条
  • [31] Timing variability and not force variability predicts the endpoint accuracy of fast and slow isometric contractions
    Poston, Brach
    Christou, Evangelos A.
    Enoka, Joel A.
    Enoka, Roger M.
    EXPERIMENTAL BRAIN RESEARCH, 2010, 202 (01) : 189 - 202
  • [32] MYOTHERMAL AND INTRAMUSCULAR PRESSURE MEASUREMENTS DURING ISOMETRIC CONTRACTIONS OF HUMAN QUADRICEPS MUSCLE
    EDWARDS, RHT
    MCDONNELL, M
    HILL, DK
    JOURNAL OF PHYSIOLOGY-LONDON, 1972, 224 (02): : P58 - +
  • [33] Timing variability and not force variability predicts the endpoint accuracy of fast and slow isometric contractions
    Brach Poston
    Evangelos A. Christou
    Joel A. Enoka
    Roger M. Enoka
    Experimental Brain Research, 2010, 202 : 189 - 202
  • [34] USE OF RUSSIAN AND AUSSIE CURRENT IN ISOMETRIC TETANIZATION OF THE QUADRICEPS FEMORIS
    Nepomuceno Montenegro, Eduardo Jose
    dos Santos, Karina Vilela
    de Alencar, Geisa Guimaraes
    de Siqueira, Gisela Rocha
    Maia, Juliana Netto
    Andrade, Maria do Amparo
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2019, 25 (02) : 142 - 146
  • [35] Dynamic modeling of SEMG-force relation in the presence of muscle fatigue during isometric contractions
    Asefi, Moein
    Moghimi, Sahar
    Kalani, Hadi
    Moghimi, Ali
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 28 : 41 - 49
  • [36] Removal of visual feedback alters muscle activity and reduces force variability during constant isometric contractions
    Harsimran S. Baweja
    Bhavini K. Patel
    Julie D. Martinkewiz
    Julie Vu
    Evangelos A. Christou
    Experimental Brain Research, 2009, 197 : 35 - 47
  • [37] Removal of visual feedback alters muscle activity and reduces force variability during constant isometric contractions
    Baweja, Harsimran S.
    Patel, Bhavini K.
    Martinkewiz, Julie D.
    Vu, Julie
    Christou, Evangelos A.
    EXPERIMENTAL BRAIN RESEARCH, 2009, 197 (01) : 35 - 47
  • [38] Detection of the electromechanical delay and its components during voluntary isometric contraction of the quadriceps femoris muscle
    Begovic, Haris
    Zhou, Guang-Quan
    Li, Tianjie
    Wang, Yi
    Zheng, Yong-Ping
    FRONTIERS IN PHYSIOLOGY, 2014, 5
  • [39] Quadriceps femoris electromyogram during concentric, isometric and eccentric phases of fatiguing dynamic knee extensions
    Pincivero, DM
    Gandhi, V
    Timmons, MK
    Coelho, AJ
    JOURNAL OF BIOMECHANICS, 2006, 39 (02) : 246 - 254
  • [40] EFFECT OF STABILIZATION ON MAXIMAL ISOKINETIC TORQUE OF THE QUADRICEPS FEMORIS MUSCLE DURING CONCENTRIC AND ECCENTRIC CONTRACTIONS
    HANTEN, WP
    RAMBERG, CL
    PHYSICAL THERAPY, 1988, 68 (02): : 219 - 222